HomeMy WebLinkAbout6126 HAWKS PERCH LN - DISCLOSURES - 2/17/2020BUILDING LEAKAGE TEST Date of Test: 2/17/2020 Test File: 6126 Hawks Perch Lane final tectite (1) Technician: Andrew Hannig - Burgess Construction Consultants Inc. Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 6126 Hawks Perch Lane Fort Collins, Colorado 80528 Test Results at 50 Pascals: cfm50 Airflow 2123 (+/- 0.9 %) ACH50 2.45 cfm/ft² (Floor Area) 0.4148 cfm/ft² (Surface Area) 0.1922 Leakage Areas: 325.2 in² (+/- 6.2 %) Canadian EqLA @ 10 Pa or 0.0294 in²/ft² Surface Area 216.8 in² (+/- 9.9 %) LBL ELA @ 4 Pa or 0.0196 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 435.8 (+/- 15.4 %) Exponent (n) = 0.405 (+/- 0.040) Correlation Coefficient = 0.99632 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 700 800 900 1000 2000 3000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/17/2020 Test File: 6126 Hawks Perch Lane final tectite (1) Building Information Volume (ft³) 52076 Surface Area: (ft²) 11046 Floor Area: (ft²) 5118 Height (ft) 10.17 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/17/2020 Test File: 6126 Hawks Perch Lane final tectite (1) Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 67.0 39.0 Post-Test 67.0 39.0 Average 67.0 39.0 4876.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.9 n/a n/a -65.0 -62.8 182.9 2410 2338 0.4 Ring A -60.0 -57.8 171.4 2335 2265 0.6 Ring A -55.0 -52.8 157.4 2240 2173 0.1 Ring A -50.0 -47.8 141.3 2125 2062 -1.1 Ring A -45.0 -42.8 129.3 2035 1974 -1.0 Ring A -40.0 -37.8 118.4 1950 1891 -0.2 Ring A -35.0 -32.8 108.1 1865 1809 1.1 Ring A -2.5 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - n value (0.405) outside of acceptable limits (0,5 ≤ n ≤ 1). - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2/17/2020 Test File: 6126 Hawks Perch Lane final tectite (1) Comments Garage with Respect to House @50PA47.2