Loading...
HomeMy WebLinkAbout424 E STUART ST - DISCLOSURES - 1/14/2020BUILDING LEAKAGE TEST Date of Test: 1/14/2020 Test File: Untitled Technician: John Gokosivil Project Number: Customer: Christopher Serbousek 7471 County Road 74 Windsor, CO 80550 Phone: 303-419-6781 Building Address: 424 E. Stuart Street Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 983 CFM50 ( +/- 1.2 %) (50 Pa = 0.2 w.c.) 1.76 ACH50 2. Leakage Area: 54.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 71.3 ( +/- 8.4 %) Exponent (n) = 0.671 ( +/- 0.023 ) Correlation Coefficient = 0.99940 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 45.1 CFM 0.08 ACH 2. Estimated Design Infiltration Rate: Winter: 65.9 CFM 0.12 ACH Summer: 48.3 CFM 0.09 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 58.9 CFM Base Rate: 58.9 CFM BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 1/14/2020 Test File: Untitled Building Information Volume 33513 Surface Area Floor Area 2892 Height 9 # of Bedrooms 3 # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 24591 2/3/2017 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 1/14/2020 Test File: Untitled Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 73.0 36.0 5000.0 Data Points - Automated Test (TT 4.0.52.3) Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -4.5 n/a n/a -64.1 -59.5 40.3 1152 1115 1.0 Ring A -58.5 -53.9 34.2 1063 1029 -0.4 Ring A -52.2 -47.6 29.2 984 953 0.2 Ring A -47.0 -42.4 238.8 915 885 0.7 Ring B -41.3 -36.7 186.4 809 783 -1.9 Ring B -34.0 -29.4 142.1 707 685 -0.6 Ring B -28.9 -24.3 111.9 628 608 0.6 Ring B -22.6 -18.0 74.9 515 498 0.5 Ring B -4.7 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 1/14/2020 Test File: Untitled Comments None