HomeMy WebLinkAbout920 TOD DR - DISCLOSURES - 11/28/2019BUILDING LEAKAGE TEST Date of Test: 11/28/2018 Test File: 920 Tod Dr LC Home TECTITE Technician: Zach Kimbrough - EnergyLogic Project Number: 53483 Customer: LC Home Phone: Fax: Building Address: 920 Tod Dr Ft Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 1389 (+/- 0.6 %) ACH50 2.47 cfm/ft² (Floor Area) 0.4089 Leakage Areas: 154.8 in² (+/- 2.3 %) Canadian EqLA @ 10 Pa 86.1 in² (+/- 3.8 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 131.5 (+/- 6.0 %) Exponent (n) = 0.603 (+/- 0.016) Correlation Coefficient = 0.99964 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/28/2018 Test File: 920 Tod Dr LC Home TECTITE Building Information Volume (ft³) 33734.48 Surface Area: (ft²) Floor Area: (ft²) 3398.5 Height (ft) 20 Year of Construction 2018 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 26986 8/2/2010 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/28/2018 Test File: 920 Tod Dr LC Home TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 55.0 Post-Test 70.0 55.0 Average 70.0 55.0 5100.0 Data Points - Automated Test (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -11.6 n/a n/a -70.0 -62.6 76.6 1577 1574 -1.0 Ring A -64.3 -56.9 70.5 1514 1511 0.6 Ring A -58.6 -51.2 61.3 1414 1411 0.1 Ring A -51.3 -43.9 51.3 1297 1294 0.7 Ring A -48.9 -41.4 46.7 1239 1236 -0.4 Ring A -42.8 -35.3 38.9 1133 1130 0.3 Ring A -36.2 -28.7 30.1 999 997 0.2 Ring A -28.8 -21.4 197.1 832 830 -0.4 Ring B -3.2 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/28/2018 Test File: 920 Tod Dr LC Home TECTITE Comments Garage to House Connection: 46 PA