Loading...
HomeMy WebLinkAbout4438 HUNTSMAN DR - DISCLOSURES - 4/18/2019BUILDING LEAKAGE TEST Date of Test: 4/18/2019 Test File: 4438 Huntsman 1.65ACH 4.22.2019 Technician: Neal Girard - EnergyLogic Project Number: 54761 Customer: LC Home Phone: Fax: Building Address: 4438 Huntsman Dr Ft Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 907 (+/- 2.4 %) ACH50 1.65 cfm/ft² (Floor Area) 0.2669 Leakage Areas: 93.0 in² (+/- 11.7 %) Canadian EqLA @ 10 Pa 49.4 in² (+/- 18.8 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 70.2 (+/- 29.5 %) Exponent (n) = 0.654 (+/- 0.078) Correlation Coefficient = 0.99470 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4/18/2019 Test File: 4438 Huntsman 1.65ACH 4.22.2019 Building Information Volume (ft³) 33084 Surface Area: (ft²) Floor Area: (ft²) 3399 Height (ft) 20 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 36002 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/18/2019 Test File: 4438 Huntsman 1.65ACH 4.22.2019 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 46.0 Post-Test 70.0 46.0 Average 70.0 46.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -3.0 n/a n/a -66.0 -63.6 33.8 1058 1045 -1.6 Ring A -60.0 -57.6 30.2 1001 989 -0.6 Ring A -54.0 -51.6 25.8 927 916 -1.1 Ring A -48.0 -45.6 230.6 899 888 4.0 Ring B -42.0 -39.6 181.8 799 789 1.4 Ring B -36.0 -33.6 142.0 707 699 -0.2 Ring B -30.0 -27.6 105.8 611 604 -1.8 Ring B -1.8 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4/18/2019 Test File: 4438 Huntsman 1.65ACH 4.22.2019 Comments GARAGE 49 Pa Mech. NA