Loading...
HomeMy WebLinkAbout902 JEROME ST - DISCLOSURES - 6/21/2019BUILDING LEAKAGE TEST Date of Test: 6/21/2019 Test File: 902 Jerome St Unit 4 2.70ACH 6.21.2019 Technician: Greydon Studer - EnergyLogic Project Number: Customer: Building Address: 902 Jerome St Unit 4 Fort Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 925 (+/- 1.9 %) ACH50 2.70 Leakage Areas: 84.8 in² (+/- 9.0 %) Canadian EqLA @ 10 Pa 42.2 in² (+/- 14.6 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 54.5 (+/- 23.2 %) Exponent (n) = 0.724 (+/- 0.062) Correlation Coefficient = 0.99722 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/21/2019 Test File: 902 Jerome St Unit 4 2.70ACH 6.21.2019 Building Information Volume (ft³) 20591 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 22 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/21/2019 Test File: 902 Jerome St Unit 4 2.70ACH 6.21.2019 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 60.0 55.0 Post-Test 60.0 55.0 Average 60.0 55.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -3.1 n/a n/a -60.0 -57.9 29.2 985 1006 -2.2 Ring A -55.0 -52.9 257.2 949 969 0.6 Ring B -50.0 -47.9 229.6 897 916 2.2 Ring B -45.0 -42.9 191.1 819 837 1.0 Ring B -40.0 -37.9 153.1 734 750 -1.0 Ring B -35.0 -32.9 126.6 668 682 -0.2 Ring B -30.0 -27.9 99.2 592 605 -0.3 Ring B -1.1 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/21/2019 Test File: 902 Jerome St Unit 4 2.70ACH 6.21.2019 Comments No Attached Garage*