Loading...
HomeMy WebLinkAbout902 JEROME ST - DISCLOSURES - 7/17/2019BUILDING LEAKAGE TEST Date of Test: 7/17/2019 Test File: 902 Jerome St unit 3 2.83ACH 7.17.2019 Technician: Greydon Studer - EnergyLogic Project Number: Customer: Building Address: 902 Jerome St Unit 3 Fort Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 771 (+/- 0.8 %) ACH50 2.83 Leakage Areas: 79.2 in² (+/- 7.3 %) Canadian EqLA @ 10 Pa 42.0 in² (+/- 11.4 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 59.9 (+/- 17.5 %) Exponent (n) = 0.653 (+/- 0.044) Correlation Coefficient = 0.99882 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/17/2019 Test File: 902 Jerome St unit 3 2.83ACH 7.17.2019 Building Information Volume (ft³) 16355 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 26 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/17/2019 Test File: 902 Jerome St unit 3 2.83ACH 7.17.2019 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 84.0 99.0 Post-Test 84.0 99.0 Average 84.0 99.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.5 n/a n/a -65.0 -65.6 215.8 870 927 0.7 Ring B -60.0 -60.6 187.8 812 865 -1.0 Ring B -55.0 -55.6 171.8 777 828 0.2 Ring B -50.0 -50.6 151.5 730 778 0.1 Ring B -45.0 -45.6 132.4 683 728 0.2 Ring B -40.0 -40.6 112.9 631 672 -0.1 Ring B 0.7 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/17/2019 Test File: 902 Jerome St unit 3 2.83ACH 7.17.2019 Comments No attached garage