HomeMy WebLinkAbout902 JEROME ST - DISCLOSURES - 7/9/2019BUILDING LEAKAGE TEST Date of Test: 7/9/2019 Test File: Untitled Technician: Zach Kimbrough - EnergyLogic Project Number: 57901 Customer: Philgreen Phone: Fax: Building Address: 902 Jerome St Unit 2 Fort Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 707 (+/- 2.2 %) ACH50 2.60 Leakage Areas: 79.4 in² (+/- 7.2 %) Canadian EqLA @ 10 Pa 44.4 in² (+/- 11.7 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 68.3 (+/- 18.7 %) Exponent (n) = 0.598 (+/- 0.051) Correlation Coefficient = 0.99894 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/9/2019 Test File: Untitled Building Information Volume (ft³) 16335 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 30 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/9/2019 Test File: Untitled Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 80.0 84.0 Post-Test 80.0 84.0 Average 80.0 84.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 1.7 n/a n/a -59.1 -60.7 166.0 764 786 -1.0 Ring B -50.4 -52.0 141.2 705 726 0.3 Ring B -40.0 -41.6 111.1 626 644 1.7 Ring B -31.3 -32.9 79.4 530 546 -0.9 Ring B -20.5 -22.1 49.9 421 433 -0.1 Ring B 1.5 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - An interval between building pressures exceeds 10 Pa. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/9/2019 Test File: Untitled Comments Detatched Garage