Loading...
HomeMy WebLinkAbout902 JEROME ST - DISCLOSURES - 6/28/2019BUILDING LEAKAGE TEST Date of Test: 6/28/2019 Test File: 902 Jerome St unit 1 2.97ACH 6.28.2019 Technician: Greydon Studer - EnergyLogic Project Number: Customer: Building Address: 902 Jerome St Unit 1 Fort Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 1020 (+/- 1.2 %) ACH50 2.97 Leakage Areas: 124.6 in² (+/- 9.0 %) Canadian EqLA @ 10 Pa 73.0 in² (+/- 14.1 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 120.7 (+/- 21.8 %) Exponent (n) = 0.546 (+/- 0.056) Correlation Coefficient = 0.99605 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/28/2019 Test File: 902 Jerome St unit 1 2.97ACH 6.28.2019 Building Information Volume (ft³) 20591 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 20 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/28/2019 Test File: 902 Jerome St unit 1 2.97ACH 6.28.2019 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 68.0 78.0 Post-Test 68.0 78.0 Average 68.0 78.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -65.0 -65.1 40.8 1160 1183 0.4 Ring A -60.0 -60.1 36.7 1101 1123 -0.4 Ring A -55.0 -55.1 33.7 1056 1078 0.2 Ring A -50.0 -50.1 30.9 1013 1033 1.1 Ring A -45.0 -45.1 244.2 925 943 -2.2 Ring B -40.0 -40.1 227.0 892 910 0.6 Ring B -35.0 -35.1 195.3 828 845 0.4 Ring B 0.2 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/28/2019 Test File: 902 Jerome St unit 1 2.97ACH 6.28.2019 Comments No attached garage