HomeMy WebLinkAbout2945 COMET ST - DISCLOSURES - 7/21/2020BUILDING LEAKAGE TEST Date of Test: 7/21/2020 Test File: 2945 Comet St 2.26ACH 7.21.2020 Technician: Greydon Studer - EnergyLogic Project Number: Customer: Building Address: 2945 Comet St Fort Collins, CO 80521 Test Results at 50 Pascals: cfm50 Airflow 1385 (+/- 4.0 %) ACH50 2.26 Leakage Areas: 128.8 in² (+/- 8.0 %) Canadian EqLA @ 10 Pa 64.6 in² (+/- 13.6 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 84.6 (+/- 22.3 %) Exponent (n) = 0.715 (+/- 0.064) Correlation Coefficient = 0.99883 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/21/2020 Test File: 2945 Comet St 2.26ACH 7.21.2020 Building Information Volume (ft³) 36783 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 25 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/21/2020 Test File: 2945 Comet St 2.26ACH 7.21.2020 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 77.0 70.0 Post-Test 77.0 70.0 Average 77.0 70.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -4.0 n/a n/a -60.0 -55.5 66.0 1466 1517 1.7 Ring A -50.0 -45.5 46.2 1232 1275 -1.5 Ring A -40.0 -35.5 33.6 1055 1092 0.7 Ring A -30.0 -25.5 186.4 809 837 -2.2 Ring B -20.0 -15.5 97.6 587 608 1.3 Ring B -5.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/21/2020 Test File: 2945 Comet St 2.26ACH 7.21.2020 Comments House to garage -46p