HomeMy WebLinkAbout2145 YEARLING DR - DISCLOSURES - 6/7/2020BUILDING LEAKAGE TEST L&L Home Performance 401 N Link Ln Fort Collins, CO 80524 Phone: 970.221.3180 Fax: 970.568.0690 Email: llinsulationjh@gmail.com Website: www.ll-insulation.com Date of Test: 6/7/2020 Test File: 2145 Yearling Dr Technician: Justin Heldenbrand Project Number: Customer: Bellisimo Inc Nico Campana 3702 Manhattan Ave ste 201 Fort Collins, CO 80526 Phone: 970.402.0919 Email: ncampana@bellisimoinc.com Building Address: 2145 Yearling Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1172 CFM50 ( +/- 1.5 %) (50 Pa = 0.2 w.c.) 2.52 ACH50 2. Leakage Area: 64.4 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 102.2 ( +/- 10.9 %) Exponent (n) = 0.624 ( +/- 0.030 ) Correlation Coefficient = 0.99883 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 74.8 CFM 0.16 ACH 12.5 CFM per person 2. Estimated Design Infiltration Rate: Winter: 128.5 CFM 0.28 ACH Summer: 80.6 CFM 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/7/2020 Test File: 2145 Yearling Dr Building Information Volume 27948 Surface Area 5840 Floor Area 2887 Height 27 # of Bedrooms 5 # of Occupants 6 Year of Construction 2020 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 43466-7-700 - Micromanometer Energy Conservatory DG700 43466 9/15/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/7/2020 Test File: 2145 Yearling Dr Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 81.0 75.0 5003.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.1 n/a n/a -60.7 -59.7 49.8 1278 1305 -0.3 Ring A -54.9 -53.9 43.6 1197 1223 -0.4 Ring A -48.8 -47.8 37.6 1114 1137 -0.1 Ring A -43.0 -42.0 32.0 1031 1052 0.1 Ring A -37.5 -36.5 26.3 936 956 -0.7 Ring A -30.9 -29.9 205.7 849 867 2.0 Ring B -24.7 -23.7 152.0 731 747 1.5 Ring B -19.2 -18.2 101.7 599 612 -2.0 Ring B -0.9 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/7/2020 Test File: 2145 Yearling Dr Comments BPI BA and Infiltration & Duct Leakage Certification ID:5060608 Connection to Mech:-50pa Connection to Garage:-45.7pa