Loading...
HomeMy WebLinkAbout240 URBAN PRAIRIE ST - DISCLOSURES - 6/12/2019BUILDING LEAKAGE TEST Date of Test: 6/12/2019 Test File: 240 Urban unit 4 Technician: Trevor Donnelly (EnergyLogic) Project Number: Customer: PhilGreen Phone: Fax: Building Address: 240 Urban Prairie Way Fort Collins, Co 80524 Test Results at 50 Pascals: cfm50 Airflow 621 (+/- 4.0 %) ACH50 2.02 Leakage Areas: 65.3 in² (+/- 11.3 %) Canadian EqLA @ 10 Pa 35.1 in² (+/- 18.7 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 51.1 (+/- 30.0 %) Exponent (n) = 0.639 (+/- 0.083) Correlation Coefficient = 0.99753 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/12/2019 Test File: 240 Urban unit 4 Building Information Volume (ft³) 18434 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 20 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/12/2019 Test File: 240 Urban unit 4 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 75.0 75.0 Post-Test 75.0 75.0 Average 75.0 75.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 126.2 667 687 -1.5 Ring B -50.0 -50.0 102.6 602 620 -0.1 Ring B -40.0 -40.0 78.8 528 544 1.0 Ring B -30.0 -30.0 56.3 447 461 2.8 Ring B -20.0 -20.0 30.3 329 339 -2.1 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/12/2019 Test File: 240 Urban unit 4 Comments House to garage: -45 Pa