HomeMy WebLinkAbout240 URBAN PRAIRIE ST - DISCLOSURES - 3/13/2019BUILDING LEAKAGE TEST Date of Test: 3/13/2019 Test File: 240 Urban Prairie St 5 Philgreen tec(1) Technician: Neal Girard - EnergyLogic Project Number: 52066 Customer: Philgreen Construction Phone: Fax: Building Address: 240 Urban Prairie St 5 Ft Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 665 (+/- 3.3 %) ACH50 1.80 cfm/ft² (Floor Area) 0.3215 Leakage Areas: 65.7 in² (+/- 8.9 %) Canadian EqLA @ 10 Pa 34.1 in² (+/- 14.7 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 47.0 (+/- 23.8 %) Exponent (n) = 0.677 (+/- 0.066) Correlation Coefficient = 0.99531 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/13/2019 Test File: 240 Urban Prairie St 5 Philgreen tec(1) Building Information Volume (ft³) 22184 Surface Area: (ft²) Floor Area: (ft²) 2068 Height (ft) 35 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/13/2019 Test File: 240 Urban Prairie St 5 Philgreen tec(1) Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 40.0 Post-Test 70.0 40.0 Average 70.0 40.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 163.4 758 742 -1.4 Ring B -54.0 -54.0 147.3 720 704 0.6 Ring B -48.0 -48.0 118.0 645 631 -2.4 Ring B -42.0 -42.0 106.8 614 601 1.7 Ring B -36.0 -36.0 82.1 539 527 -0.9 Ring B -30.0 -30.0 70.0 498 487 3.6 Ring B -24.0 -24.0 51.3 427 418 3.3 Ring B -18.0 -18.0 29.8 326 319 -4.1 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/13/2019 Test File: 240 Urban Prairie St 5 Philgreen tec(1) Comments Garage Pa -46 PA