HomeMy WebLinkAbout240 URBAN PRAIRIE ST - DISCLOSURES - 1/28/2019BUILDING LEAKAGE TEST Date of Test: 2/28/2019 Test File: 240 Urban Prairie St 2 Philgreen tec Technician: Neal Girard - EnergyLogic Project Number: 52069 Customer: Philgreen Construction Phone: Fax: Building Address: 240 Urban Prairie St 2 Ft Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 572 (+/- 1.4 %) ACH50 1.86 cfm/ft² (Floor Area) 0.3629 Leakage Areas: 52.9 in² (+/- 3.2 %) Canadian EqLA @ 10 Pa 26.5 in² (+/- 5.3 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 34.5 (+/- 8.6 %) Exponent (n) = 0.718 (+/- 0.024) Correlation Coefficient = 0.99915 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 90 100 200 300 400 500 600 700 800 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/28/2019 Test File: 240 Urban Prairie St 2 Philgreen tec Building Information Volume (ft³) 18434 Surface Area: (ft²) Floor Area: (ft²) 1576 Height (ft) 35 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 36002 11/15/2012 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/28/2019 Test File: 240 Urban Prairie St 2 Philgreen tec Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 65.0 40.0 Post-Test 65.0 40.0 Average 65.0 40.0 5000.0 Data Points - Automated Test (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -3.2 n/a n/a -62.6 -59.3 126.2 667 657 1.6 Ring B -58.4 -55.0 111.3 627 617 0.8 Ring B -52.3 -48.9 94.6 578 569 1.1 Ring B -50.0 -46.6 81.5 537 529 -2.8 Ring B -43.7 -40.3 69.3 496 488 -0.4 Ring B -39.0 -35.7 58.1 454 447 -0.3 Ring B -32.8 -29.4 43.4 393 387 -0.9 Ring B -28.4 -25.0 34.4 350 345 -0.8 Ring B -22.3 -18.9 165.6 294 290 1.9 Ring C -17.8 -14.5 110.0 238 235 0.0 Ring C -3.6 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2/28/2019 Test File: 240 Urban Prairie St 2 Philgreen tec Comments garage -45pa