HomeMy WebLinkAbout240 URBAN PRAIRIE ST - DISCLOSURES - 12/13/2018BUILDING LEAKAGE TEST Date of Test: 12/13/2018 Test File: 240 Urban Prairie Way Unit 1 Technician: Trevor Donnelly (EnergyLogic) Project Number: Customer: Philgreen Phone: Fax: Building Address: 240 Urban Prairie Way Fort Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 535 (+/- 0.8 %) ACH50 1.45 cfm/ft² (Floor Area) 0.2588 cfm/ft² (Surface Area) 0.1295 Leakage Areas: 37.2 in² (+/- 6.9 %) Canadian EqLA @ 10 Pa or 0.0090 in²/ft² Surface Area 15.8 in² (+/- 11.0 %) LBL ELA @ 4 Pa or 0.0038 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 16.1 (+/- 17.1 %) Exponent (n) = 0.896 (+/- 0.044) Correlation Coefficient = 0.99964 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 50 60 70 80 90 100 200 300 400 500 600 700 800 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/13/2018 Test File: 240 Urban Prairie Way Unit 1 Building Information Volume (ft³) 22184 Surface Area: (ft²) 4134 Floor Area: (ft²) 2068 Height (ft) 20 Year of Construction 2018 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/13/2018 Test File: 240 Urban Prairie Way Unit 1 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 72.0 40.0 Post-Test 72.0 40.0 Average 72.0 40.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -59.0 -59.0 113.6 633 624 0.5 Ring B -53.0 -53.0 91.9 570 562 -0.4 Ring B -48.0 -48.0 77.6 524 516 0.1 Ring B -44.0 -44.0 65.5 482 475 -0.5 Ring B -36.0 -36.0 46.4 406 400 0.4 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/13/2018 Test File: 240 Urban Prairie Way Unit 1 Comments H2Garage: -47 PASS