Loading...
HomeMy WebLinkAbout216 TIGERCAT WAY - DISCLOSURES - 12/26/2019BUILDING LEAKAGE TEST Date of Test: 12/26/2019 Test File: Untitled Technician: Zach Kimbrough - EnergyLogic Project Number: 62333 Customer: Lennar Phone: Fax: Building Address: 216 Tigercat Way Ft Collins, CO 80521 Test Results at 50 Pascals: cfm50 Airflow 975 (+/- 2.3 %) ACH50 2.37 cfm/ft² (Floor Area) 0.3834 Leakage Areas: 94.3 in² (+/- 5.3 %) Canadian EqLA @ 10 Pa 48.4 in² (+/- 9.0 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 65.5 (+/- 14.6 %) Exponent (n) = 0.690 (+/- 0.041) Correlation Coefficient = 0.99948 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/26/2019 Test File: Untitled Building Information Volume (ft³) 24693.02 Surface Area: (ft²) Floor Area: (ft²) 2544.0 Height (ft) 20 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/26/2019 Test File: Untitled Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 35.0 Post-Test 70.0 35.0 Average 70.0 35.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -3.3 n/a n/a -59.3 -56.5 36.4 1097 1063 0.2 Ring A -50.2 -47.4 27.5 957 927 -1.4 Ring A -40.5 -37.7 199.1 836 810 0.9 Ring B -30.5 -27.7 129.7 676 655 1.0 Ring B -20.3 -17.5 66.1 484 469 -0.7 Ring B -2.3 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - An interval between building pressures exceeds 10 Pa. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/26/2019 Test File: Untitled Comments House to Garage: 45 PA