Loading...
HomeMy WebLinkAbout6227 FALL HARVEST WAY - DISCLOSURES - 12/27/2018BUILDING LEAKAGE TEST Date of Test: 12/27/2018 Test File: 6227 Fall Harvest Way TECTITE Technician: Todd Buckner- Burgess Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 6227 Fall Harvest Way Fort Collins, CO 80582 Test Results at 50 Pascals: cfm50 Airflow 1425 (+/- 1.1 %) ACH50 2.22 cfm/ft² (Floor Area) 0.4143 cfm/ft² (Surface Area) 0.1604 Leakage Areas: 189.4 in² (+/- 7.0 %) Canadian EqLA @ 10 Pa or 0.0213 in²/ft² Surface Area 116.5 in² (+/- 11.1 %) LBL ELA @ 4 Pa or 0.0131 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 207.3 (+/- 17.3 %) Exponent (n) = 0.493 (+/- 0.045) Correlation Coefficient = 0.99683 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/27/2018 Test File: 6227 Fall Harvest Way TECTITE Building Information Volume (ft³) 38565 Surface Area: (ft²) 8884 Floor Area: (ft²) 3440 Height (ft) 11.21 Year of Construction 2018 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/27/2018 Test File: 6227 Fall Harvest Way TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 68.0 21.0 Post-Test 68.0 21.0 Average 68.0 21.0 4925.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.7 n/a n/a -65.0 -62.0 87.3 1680 1605 1.2 Ring A -60.0 -57.0 77.9 1590 1518 -0.2 Ring A -55.0 -52.0 70.1 1510 1442 -0.8 Ring A -50.0 -47.0 63.2 1436 1371 -0.9 Ring A -45.0 -42.0 58.3 1380 1318 0.7 Ring A -40.0 -37.0 49.6 1276 1218 -0.9 Ring A -35.0 -32.0 44.5 1210 1155 0.9 Ring A -3.2 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - n value (0.493) outside of acceptable limits (0,5 ≤ n ≤ 1). - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/27/2018 Test File: 6227 Fall Harvest Way TECTITE Comments Garage WRT House @50PA 46.9