Loading...
HomeMy WebLinkAbout6020 FALL HARVEST WAY - DISCLOSURES - 12/9/2019BUILDING LEAKAGE TEST Date of Test: 12/9/2019 Test File: 6020 Fall Harvest Way final Technician: - Burgess Construction Consultants Jay Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 6020 Fall Harvest Way Fort Collins, Colorado 80528 Test Results at 50 Pascals: cfm50 Airflow 1758 (+/- 0.5 %) ACH50 3.00 cfm/ft² (Floor Area) 0.6582 cfm/ft² (Surface Area) 0.2574 Leakage Areas: 173.9 in² (+/- 3.2 %) Canadian EqLA @ 10 Pa or 0.0255 in²/ft² Surface Area 90.4 in² (+/- 5.1 %) LBL ELA @ 4 Pa or 0.0132 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 124.7 (+/- 8.0 %) Exponent (n) = 0.676 (+/- 0.021) Correlation Coefficient = 0.99964 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 300 400 500 600 700 800 900 1000 2000 3000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/9/2019 Test File: 6020 Fall Harvest Way final Building Information Volume (ft³) 35175 Surface Area: (ft²) 6830 Floor Area: (ft²) 2671 Height (ft) 13.7 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/9/2019 Test File: 6020 Fall Harvest Way final Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 58.0 29.0 Post-Test 58.0 29.0 Average 58.0 29.0 4769.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.5 n/a n/a -65.0 -62.1 139.2 2110 2041 0.2 Ring A -60.0 -57.1 123.5 1990 1925 0.1 Ring A -55.0 -52.1 109.3 1875 1814 0.3 Ring A -50.0 -47.1 92.7 1730 1674 -0.9 Ring A -45.0 -42.1 80.5 1615 1563 -0.2 Ring A -40.0 -37.1 68.2 1490 1441 0.3 Ring A -35.0 -32.1 55.7 1350 1306 0.2 Ring A -3.3 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/9/2019 Test File: 6020 Fall Harvest Way final Comments Garage with Respect to House @50PA= 45.7 Pa