HomeMy WebLinkAbout894 WATERCOURSE WAY - APPLICATIONS - 6/4/2020City of COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
F„\rt Collins
281 N. College Ave. •Fort Collins, CO 80524 •Phone: 970.416.2740 e www.fceov.com/huildine
BUILDING PERMIT APPLICATION
FOR OFFICE USE
4PPLICATION NUMBER: A�7i��c5 7 L7 �J APPLICATION DATE: (, I'J ZZI
Job Site Address 894 Watercourse Way
PROPERTY OWNER INFO: (All owner information is required - NOT optional)
Last Name FIR Development First Name
Street Address 125 S Howes St 2nd Fir City Fort Collins
Phone # 970-420-1578 Email Chris@fr-corp.com
Name of Business (COMMERCIAL USE ONLY)
CONTRACTOR INFO: Company Name FR Development
License Holder Name Andrew Rauch
LEGAL INFO:
Subdivision/PUD River Modern Filing # 2 Lot # 2
CONSTRUCTON INFO: Total Building Sq Ft (NOT including basement) 3249
Residential Sq Ft 2440 Commercial Sq Ft 0 # of Stories 2
1st Floor Sq Ft 1178 2nd Floor Sq Ft 1262 3rd Floor Sq Ft
Finished Basement Sq Ft 0 # of Bedrooms 4
% Baths 1 Yz Baths 0 # Fireplaces 1
ENERGY INFORMATION: (CHECK ONE)
Unit#
_Middle
State CO Zip 80521
LIC # D-755 CERT #
Block # - Lot Sq Ft 4134
Total Garage Sq. Ft. 809
Bldg Ht 26' 21, # of Dwelling Units 1
Unfinished Basement Sq Ft 1204
# of Full Baths 2
ComCheck ❑ UA (ResCheck) ❑ SPA (Simulated Performance ❑ prescriptive❑
Alternative)
Air Conditioning? YES ❑ NO ❑
City of Fort Collins Approved Stock Plan # SPO List Option #s
ERI(Energy Rating Index) ❑
UTILITIES INFO: Gas ❑ Electric ❑ Electric Temp. Pedestal Yes ❑ No ❑
Electric Main Breaker Size (Residential Only): 150 amp or less ❑ 200 Amp ❑ Other ❑
ZONING INFO: (COMMERCIAL USE ONLY)
Proposed Use: (i.e. medical, office, bank, retail, etc.)
For Commercial remodels and tenant finishes. please answer the followine auestions:
Is the remodel/tenant finishes for an existing or new tenant? (Please check one)
Existing Tenant[] New Tenant❑
If for a new tenant, is this the first tenant to occupy this space?
Yes ❑ No ❑ If not for the initial tenant for this unit, what was the previous use of this tenant space?
Are there any exterior building changes (including mechanical) associated with the work? Yes ❑ No ❑
If yes, please describe:
Value of Construction (materials and labor): $ 293,000
Description of Work: 2 story, 2440sf single family home with 1204sf unfinished basement and 809sf
attached garage. City water, prescriptive energy with blower door test.
JOBSITE SUPERVISOR CONTACT INFO: Name Marcial Tapia
SUBCONTRACTOR INFO: Electrical Gillen Wiring
Plumbing IPS
Phone 970-690-8099
Mechanical Air Products
Framing FIR Development Roofing Elite Roofin
Fireplace Western Fireplace Solar
Other -
ASBESTOS STATEMENT DISCLOSURE: In accordance with the State of Colorado Senate Bill 13-152, property owners, applying for a
remodel permit shall indicate their awareness about their property having been inspected forAsbestos Containing Materials (ACM's).
❑ I do not know if an asbestos inspection has been conducted on this property.
❑ An asbestos inspection has been conducted on this property on or about (enter date)
❑ An asbestos inspection has not been conducted on this property.
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to
comply with all requirements contained herein and City of Fort Collins ordinances and state laws regulating building construction.
Applicant Signature
Phone # 970-420-1578
Type or Print Name Chris Wilson
Email chris@fr-corp.com
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
Fiof
t Collins
Planning, Development & Transportation Services
Community Development & Neighborhood Services
81 North College Avenue
Fort Collins, CO 80524
970.416.2740
Building Permit Submittal Checklist:
New Single Detached Family Homes, Duplexes, Townhomes, and Additions
Incomplete or deferred submittals will not be accepted
Required at the time of permit
Drawings depicting the scope of work
submittal Electronic submittal required.
✓ Building Permit Application
✓
✓
Plans must reflect current adopted codes and standards:
www.fcgov.com/building/-codes.php
✓
Mechanical Design Form and Load Calcs
Homeowner Affidavit (homeowner builders only)
Plan Check Fee (Payment by check only) Additional fee is required for
an F&F permit.
Energy Code Compliance Form
✓
Construction Waste Management Plan Form
NA=Not AR_Rlicable NIS=Not in: scop�
(nnaLy require a separate submittal, or review Prpce�S)--
Stamped & Signed Drawings by a Colorado Licensed Engineer/Architect
Separate Demo Permit: Required for Full or Partial demolition of exterior
are required for:
elements.
✓
All footing and foundation work
Separate Solar Permit: Required for all new solar
(new or altered).
Architectural Drawings:
Historic Preservation Review
Existing Drawings showing re -demo condition
www.fcgov.com/historicpreservation
Proposed Floor Plans with room labels and areas
Alterations to, or Demolitions of buildings more than 50 years old will be
reviewed for Historic Eligibility
Exterior Elevations, Building Section, Details
Townhomes only: Accessibility plan CRS 9-5
Grading
Structural Drawings:
WaterUtilitesEng@fcgov.com
Sheer: wall bracing and method used, wind speed used, wind
Grading plan may be required if impervious area on lot is greater than
speed method, wind speed exposure.
350sf.
Loads: Floor and roof loads used.
Are you building in a Floodplain?
✓
Framing Plans: Floor, Roof, Girders and Headers
No
https://www.fcgov.com/utilities/what-we-
do/stormwater/flooding/flood pla i n-maps-documents
Connections and details. (provide stair details)
Zoning: 281 N College / (970) 416-2745
Mechanical Load Calcs (required for new forced air systems including new
Contact Zoning for questions on: Setbacks, easements, buildable area
secondary systems for additions)
v/
per lot, and short term rentals.
X IManual J,D,S (ACCA approved only)
zoning@fcgov.com
Electrical Drawing Furnace
Poudre Fire Authority: 102 Remington / (970)-416-2891
✓ JOutlets, lighting, panel, equipment.
https://www.poudre-fire.org/online-services
Site Plan
NIS
If using NFPA 13D,13R or 13 Fire Suppression Systems, a separate
submittal is required through the Poudre Fire Authority website.
✓
Shaw distance from new work to property lines, and adjacent
structures on the same lot.
Fire Details
Optional
'(new homes
FootingFoundation
only,.allowed for additions)
Submit for full permit with an additional F&F set
Townhomes and Duplexes only :Fire separation details and fire
F&F Set: Structural Foundation Plans (stamped), Underground plumbing
sprinkler systems under P2904 must be submitted for review.
and electric (for townhomes only).
Applicant Name: Chris Wilson
Job Site Address: 894 Watercourse Way
Fort Collins, CO 80525
Phone: 970-420-1578
Email (Required): chris@fr-corp.com