HomeMy WebLinkAbout2430 SPRUCE CREEK DR - DISCLOSURES - 7/1/2019Envelope Leakage Test Testing Company: Technician: Name: Home Performance Solutions LLC Name: Michael Krebs Address: Castle Rock, CO Credentials: Rating Field Inspector Email: mike@hpsenergy.com Building Information: Project ID: 2430 Soruce Creek Dr Address: 2430 Spruce Creek Dr Fort Collins, CO 80528 Geo-Tag Data: Latitude: 40.503746 Longitude:-105.032711 Ti mestamp: 2019-07-01 15:47:17 Measured Leakage: 2.94 ACH5O Leakage Target: 3.00 ACH50 Compliance with Leakage Target: Pass Test ID: Purpose of Test: Measured CFM50: Building Volume: Flow Coefficient (C): Correlation Coefficient Test Standard: Test Characteristics: Test Date and Time: Test 1 IECC 12/15 Env. Leakage 1,844.9 (+/- 9.5%) 37,632.0 ft3 120.6 (+/- 66.0%) 0.96734 ASTM E779 (single mode) Pre Indoor Temp: 72 OF Pre Outdoor Temp: 84 OF Altitude: 4,895.0 ft 2019-07-01 15:49:54 3000 2000 E w U d Y 1000 m 900 800 700 600 500 400 300 o Depressurize — Customer Information: Name: Rah Address: Effective Leakage Area: 90.0 in Enclosure Surface Area: 0.0 ftz Exponent (n): 0.697 (+/- 0.183) Test Mode: Depressurize Post Indoor Temp: 72 OF Post Outdoor Temp: 84 OF Time Average Period: 10 seconds 4 5 6 7 8 910 20 30 40 50 60 70 Building Pressure (Pa) Envelope Leakage Test (Page 2) Test Readings: Target (Pa). Bldg_(Pa). Adj Bldg -(Pa), Fan (Pa). Flow (cfm). Config Baseline -2.2 -60.0 -64.3 -61.8 -130.1 2,041.0 Ring A -54.0 -55.0 -52.5 -114.3 1,916.5 Ring A -48.0 -51.7 -49.2 -85.7 1,665.1 Ring A -42.0 -41.4 -39.0 -75.1 1,561.7 Ring A -36.0 -39.6 -37.2 -63.6 1,439.4 Ring A -30.0 -34.9 -32.5 -39.8 1,145.5 Ring A -24.0 -28.4 -26.0 -28.9 979.2 Ring A -18.0 -18.0 -15.6 -203.2 844.4 Ring B Baseline -2.7 Test Equipment: Flow Device: Model 3 110V Fan Pressure Gauge: DG700 Serial #: 39289 Calibration Date: 2017-04-06 Deviations from Standard: • The interval between building pressures is greater than 10 Pa. • Correlation coefficient is outside of normally accepted limits. Comments: -47.2 Pascals to garage=Passed Report generated by TEC Auto Test version 1.5.0 (29), © 2019 by The Energy Conservatory, Inc.