Loading...
HomeMy WebLinkAbout6714 SNOWDON ST - DISCLOSURES - 2/27/2019�b18c)Z`►5(e BUILDING LEAKAGE TEST A Green Your Home TopBuild Home Services Environments for Living 260 Jimmy Ann Dr Daytona Beach, FL 32114 mail: Colleen.Locker@TopBuild.com Website: www.environmentsforliving.coi Date of Test: 2/27/2019 Test File: 6714 Snowdon Dr - Marigold Customer: Insignia Homes Technician: Colleen Fitz -Gerald Dan Moore 550 N Lincoln Ave Loveland, CO 80537 Phone: 970-379-7696 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates Project Number: Building Address: 6714 Snowdon Ave Fort Collins, CO 80526 1712 CFM50 (+/- 2.7 %) 2.52 ACH50 94.1 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 128.9 (+/- 21.4 %) Exponent (n) = 0.661 ( +/- 0.055 ) Correlation Coefficient = 0.99655 Test Standard: RES NET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Greco Your Home Date of Test: 2/27/2019 Test File: 6714 Snowdon Dr - Marigold Building Information Location Climate Information Volume 40779 Surface Area Floor Area 4107 Height # of Bedrooms # of Occupants Year of Construction 2019 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 1 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 9876 - Micromanometer Energy Conservatory DG700 e AV m BUILDING LEAKAGE TEST Page 3 of 4 G. Y. Nome Date of Test: 2/27/2019 Test File: 6714 Snowdon Dr - Marigold Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 65.0 20.0 5280.0 Data Points - Data Entered Manually (TT 4.0.52.3) Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.4 n/a n/a -19.9 -18.5 27.1 950 900 1.5 Ring A -31.6 -30.2 49.9 1279 1213 -1.1 Ring A -40.3 -38.9 74.1 1551 1471 1.4 Ring A -50.4 -49.0 96.8 1767 1675 -0.8 Ring A -61.1 -59.7 119.2 1956 1854 -3.7 Ring A -70.3 -68.9 151.8 2201 2086 -1.4 Ring A -75.1 -73.7 166.0 2299 2179 -1.5 Ring A -85.9 -84.5 30.9 2703 2562 5.8 Open -1.4 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 c.�raP� Date of Test: 2/27/2019 Test File: 6714 Snowdon Dr - Marigold Comments House to Garage: -45.0 Pa