HomeMy WebLinkAbout418 LYONS ST - DISCLOSURES - 5/9/2018THIS EFFICIENT HOUSE`
Home Improvements that Pay For Themselves
BUILDING LEAKAGE TEST
Mike Truitt
This Efficient House
1600 Crescent Drive Fort Collins CO 80526
mike truitt@thisefficienthouse com
http //www thisefficienthouse com/index html
Date of Test 05/09/2018
Customer John and Hillary Mizia
Building Location 418 Lyons Fort Collins CO 80521
Technician Mike Truitt
Test Results Summary
1 Airflow at 50 Pascals
2 Leakage Area
3 Building Leakage Curve
53163 CFM +/ 1 6%
28 33 in^2 LBL ELA @ 4 Pa
Flow Coefficient = 39 871(+/ 11 00%)
Exponent (n) = 662 (+/ 0 044)
Correlation Coefficient = 99832
4 Test Settings Test Standard RESNET Multi Point Test
In compliance with ASTM E 779 10
Test Mode Depressurization
5 Accuracy Level Standard Accuracy
This Efficient House Building Leakage Test Date of Test 05/09/2018 Report 05092018
`r .,tea"
y THIS EFFICIENT HOUSE
Home Improvements that Pay For Themselves
Results
Air Change Rate
1 150 / hr @ 50 Pascal
+/ 1 6%
Flow / Unit Floor Area
0 2658 CFM/ft^2
Equivalent Leakage Area
53 89 in^2 at 10 Pa
+/ 3 9
LBL Effective Leakage Area
28 33 inA2 at 4 Pa
+/ 6 7
This Efficient House Building Leakage Test Date of Test 05/09/2018 Report 05092018
�& �
THIS EFFICIENmT HOUSE
Home Improvements that Pay ForThemselves
Building Information
Volume
27 726 ft^3
Floor Area
2000
# of Bedrooms
3
Year Of Construction
2018
Elevation Above Sea Level
4 950 ft
Heating And Cooling
Heating Fuel
Gas Radiant Floor
Cooling
NA
Equipment Information
Type
Maufacturer
Model
Serial Number
Calibration
Fan
Retrotec
2000
Micromanometer
Retrotec
DM 2
201213
Verified
Depressurization Test
Environmental Data
Indoor Temp (F)
Outdoor Temp (F)
I Altitude (ft)
68
73
1 4 950
Data Points
Induced Pressure (Pa) Total Flow (CFM) Corrected Flow (CFM) % Error
1623
241 097
263 082
130
1719
254 929
278 175
050
2569
337 377
368 142
190
3005
356 443
388 947
290
342
391 953
427 695
200
3466
418 156
456 287
360
4029
45253
493 795
150
5424
542 968
59248
000
5774
565 478
617 043
010
5972
576 112
628 646
040
6371
599 263
65393
080
This Efficient House Building Leakage Test Date of Test 05/09/2018 Report 05092018
COMMISSIONING REPORT 11111i'1ain5tream
CA1tome` John Mizia
- 5/10/2018
418 Ly6ns St
Order Number. 47
City, state. Zip Fort Collins CO
68
MainStream Corporatlon
John Mizia
Dole - 1/0/1900
VENTILATION MEASUREMENTS
!strth24
n. 1m
Medium
Measured CFM
Low Medium High
12 24 37
Valve Type
STB-2
Valve Position or ComfoSet Disk 0-4
20 mm
ath
24
15
30
46
STB-2
20 mm
12
8
15
26
STB-2
20 mm
12
30
20
32
STB-2
20 mm
36
20
38
60
STB-2
30 mm
eth
12
6
12
22
STB-1
10 mm
th
24
12
22
35
STB-2
20 mm
144
83
1 161
258
Bed 2 -blue
aw OW
Medium
18
Measured CFM
Law Medium High
13 24 38
Valve Type
KE
Valve Position or ComfoSet Disk 0-4
3 thread
1 Bed 3 - big
18
9
19
30
KE
3 thread
3 Master Closet
12
10
16
31
KE
2 thread
4 Master Bed
24
15
26
45
KE
3 thread
5 Living
24
8
20
30
KE
3 thread
o Dining
36
19
36
58
KE
4 thread
7. Media Room
18
12
22
40
KE
2 thread
SUM:
150
86
163
272
Ipv
Medium
High
Cnnrat Temp.ah.e
74
M
35
55
85
NR-
New
Vb'b10m"tabig
H Air:
35
60
100
weal-
68 sunny no wind
zeh'�a�
always
around you
540 Portsmouth Avenue
Greenland, NH 03840 USA
T 603 422 6700. F 603 422 9611 . Toll Free 888 778 6701 . www.zehnderamenw.com
For questions regarding this commissioning email Cody@MainStreamCorporation.com
Lava-�i/ 1oh)