Loading...
HomeMy WebLinkAbout418 LYONS ST - DISCLOSURES - 5/9/2018THIS EFFICIENT HOUSE` Home Improvements that Pay For Themselves BUILDING LEAKAGE TEST Mike Truitt This Efficient House 1600 Crescent Drive Fort Collins CO 80526 mike truitt@thisefficienthouse com http //www thisefficienthouse com/index html Date of Test 05/09/2018 Customer John and Hillary Mizia Building Location 418 Lyons Fort Collins CO 80521 Technician Mike Truitt Test Results Summary 1 Airflow at 50 Pascals 2 Leakage Area 3 Building Leakage Curve 53163 CFM +/ 1 6% 28 33 in^2 LBL ELA @ 4 Pa Flow Coefficient = 39 871(+/ 11 00%) Exponent (n) = 662 (+/ 0 044) Correlation Coefficient = 99832 4 Test Settings Test Standard RESNET Multi Point Test In compliance with ASTM E 779 10 Test Mode Depressurization 5 Accuracy Level Standard Accuracy This Efficient House Building Leakage Test Date of Test 05/09/2018 Report 05092018 `r .,tea" y THIS EFFICIENT HOUSE Home Improvements that Pay For Themselves Results Air Change Rate 1 150 / hr @ 50 Pascal +/ 1 6% Flow / Unit Floor Area 0 2658 CFM/ft^2 Equivalent Leakage Area 53 89 in^2 at 10 Pa +/ 3 9 LBL Effective Leakage Area 28 33 inA2 at 4 Pa +/ 6 7 This Efficient House Building Leakage Test Date of Test 05/09/2018 Report 05092018 �& � THIS EFFICIENmT HOUSE Home Improvements that Pay ForThemselves Building Information Volume 27 726 ft^3 Floor Area 2000 # of Bedrooms 3 Year Of Construction 2018 Elevation Above Sea Level 4 950 ft Heating And Cooling Heating Fuel Gas Radiant Floor Cooling NA Equipment Information Type Maufacturer Model Serial Number Calibration Fan Retrotec 2000 Micromanometer Retrotec DM 2 201213 Verified Depressurization Test Environmental Data Indoor Temp (F) Outdoor Temp (F) I Altitude (ft) 68 73 1 4 950 Data Points Induced Pressure (Pa) Total Flow (CFM) Corrected Flow (CFM) % Error 1623 241 097 263 082 130 1719 254 929 278 175 050 2569 337 377 368 142 190 3005 356 443 388 947 290 342 391 953 427 695 200 3466 418 156 456 287 360 4029 45253 493 795 150 5424 542 968 59248 000 5774 565 478 617 043 010 5972 576 112 628 646 040 6371 599 263 65393 080 This Efficient House Building Leakage Test Date of Test 05/09/2018 Report 05092018 COMMISSIONING REPORT 11111i'1ain5tream CA1tome` John Mizia - 5/10/2018 418 Ly6ns St Order Number. 47 City, state. Zip Fort Collins CO 68 MainStream Corporatlon John Mizia Dole - 1/0/1900 VENTILATION MEASUREMENTS !strth24 n. 1m Medium Measured CFM Low Medium High 12 24 37 Valve Type STB-2 Valve Position or ComfoSet Disk 0-4 20 mm ath 24 15 30 46 STB-2 20 mm 12 8 15 26 STB-2 20 mm 12 30 20 32 STB-2 20 mm 36 20 38 60 STB-2 30 mm eth 12 6 12 22 STB-1 10 mm th 24 12 22 35 STB-2 20 mm 144 83 1 161 258 Bed 2 -blue aw OW Medium 18 Measured CFM Law Medium High 13 24 38 Valve Type KE Valve Position or ComfoSet Disk 0-4 3 thread 1 Bed 3 - big 18 9 19 30 KE 3 thread 3 Master Closet 12 10 16 31 KE 2 thread 4 Master Bed 24 15 26 45 KE 3 thread 5 Living 24 8 20 30 KE 3 thread o Dining 36 19 36 58 KE 4 thread 7. Media Room 18 12 22 40 KE 2 thread SUM: 150 86 163 272 Ipv Medium High Cnnrat Temp.ah.e 74 M 35 55 85 NR- New Vb'b10m"tabig H Air: 35 60 100 weal- 68 sunny no wind zeh'�a� always around you 540 Portsmouth Avenue Greenland, NH 03840 USA T 603 422 6700. F 603 422 9611 . Toll Free 888 778 6701 . www.zehnderamenw.com For questions regarding this commissioning email Cody@MainStreamCorporation.com Lava-�i/ 1oh)