Torey Lenoch
417 Grant Avenue
Fort Collins, CO 80521
RE: 417 Grant Avenue Framing Inspection Letter
Larsen Structural Design Project No. 1824
Mr. Lenoch:
DESIGNING SMARTER STRUCTURES
�►�o s 1 S'1
On Monday, March 6, 2017, you contacted me to perform a framing inspection to review items
identified by the City of Fort Collins framing inspector as needing review and verification by our
office. This site visit was made to specifically inspect the headers, king and trimmer studs installed
at all wall openings as required by the construction documents dated May 21, 2014 and the
construction documents with revision #1 dated November 29, 2016. In addition to the wall
openings, the city inspector identified a shear wall strap detail that needed to be inspected and
verified.
While on site, I inspected the framing around all window and door openings specifically pertaining
to the headers, trimmer and king studs. All openings were found to have the appropriate number
of trimmer and king studs and properly sized headers and were in general accordance with the
structural construction documents.
In addition to inspecting the wall openings, I inspected the shearwall strap installed in the west
wall directly adjacent to the stair opening as required per detail 9/S2.2 at the main floor level. The
strap was found to be installed as required per detail 9/S2.2 and in general accordance with the
structural construction documents.
This concluded the extents of the framing inspection 1 performed at 417 Grant Street on Monday,
March 6, 2017.
We thank you for the opportunity to be of service to you on this project. Please contact us if you
have any question regarding this letter or if we can be of further service to you.
Respectfully,
LARSEN Structural Design
Eric L. Richards, P.E.