Loading...
HomeMy WebLinkAbout424 E STUART ST - APPLICATIONS - 4/2/2019City of COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES F, 6rt Collins 281 N. College Ave. •Fort Collins, CO 80524 • Phone: 970.416.2740 • www.fcRov.com/buildins BUILDING PERMIT APPLICATION FOR OFFICE USE APPLICATION NUMBER: 5 1 q n`q(, (a APPLICATION DATE: y ZZ Job Site Address 424 E. Stuart, Fort Collins, CO 80525 Unit# PROPERTY OWNER INFO: (All owner information is required — NOT optional) Last Name Servousek First Name Chris Middle Street Address 74488 Hannah Way City Windsor State CO Zip 80550 Phone # 303-419-6781 Email serbousekhomes@msn.com Name of Business (COMMERCIAL USE ONLY) CONTRACTOR INFO: Company Name G.Orr Construction License Holder Name Greg orr LIC # LEGAL INFO: Subdivision/PUD Filing # Lot # CERT # Block # Lot Sq Ft CONSTRUCTON INFO: Total Building Sq Ft (NOT including basement) 2,892 Total Garage Sq. Ft. 480 Residential Sq Ft 2892 Commercial Sq Ft # of Stories Bldg Ht # of Dwelling Units 1st Floor Sq Ft 1, 7 63 2nd Floor Sq Ft 1,129 3rd Floor Sq Ft Unfinished Basement Sq Ft Finished Basement Sq Ft # of Bedrooms # of Full Baths Baths X Baths # Fireplaces ENERGY INFORMATION: (CHECK ONE) ComCheck ❑ UA (Rescheck) ❑ SPA(Simulated Performance ❑ PrescriptiveCK ERI(Energy Rating Index) ❑ Alternative) Air Conditioning? YES ® NO ❑ City of Fort Collins Approved Stock Plan # SPO List Option #s UTILITIES INFO: Gas ❑ Electric ❑ Electric Temp. Pedestal Yes ❑ No ❑ Electric Main Breaker Size (Residential Only): 150 amp or less ❑ 200 Amp ❑ Other ❑ ZONING INFO: (COMMERCIAL USE ONLY) Proposed Use: (i.e. medical, office, bank, retail, etc.) For Commercial remodels and tenant finishes. Please answer the followins questions: Is the remodel/tenant finishes for an existing or new tenant? (Please check one) Existing Tenant[] New Tenant[] If for a new tenant, is this the first tenant to occupy this space? Yes ❑ No ❑ If not for the initial tenant for this unit, what was the previous use of this tenant space? Are there any exterior building changes (including mechanical) associated with the work? Yes ❑ No ❑ If yes, please describe: Value of Construction (materials and labor): . $ 337,500 Description of Work: Existing home to be removed down to foundations and floor deck new home with small addition to replace previous home. JOBSITE SUPERVISOR CONTACT INFO: Name Greg Orr , ' Phone 970-567-6841 SUBCONTRACTOR INFO: Electrical conduct all Electric Mechanical Northern Colo Air Plumbing QT Mechanical Framing Fireplace Solar TBD Roofing Tico' s Other ASBESTOS STATEMENT DISCLOSURE: In accordance with the State of Colorado Senate Bill 13-152, property owners, applying for a remodel permit, shall indicate their awareness about their property having been inspected forAsbestos Containing Materials (RCM's). ❑ I do not know if an asbestos inspection has been conducted on this property. ❑ An asbestos inspection has been conducted on this property on or about (enter date) ❑ An asbestos inspection has not been conducted on this property. Applicant: 1 hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and City of Fort Collins ordinances and state laws regulating building construction. Applicant Signature q4e-5-� Type or Print Name Greg Orr Phone# 970-567-6841 Email gory@gorrconstruction.com THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE City of Submittal Guide Fort Collins New Residential and Additions Use this Guide for: w■■ Single Family Home (Detached) -House •,' Single House, on a single lot, A-.;l.ot.-. 3 stories max Property lines Duplex (Attached) 2 Units max on a single lot, 3 ® 1 z stories max, side -by -side or over- . under. Townhome (Attached) 2 or more units, each unit is on a separate lot, 3 stories max. Addition Adding new interior area to an existing structure, such as: enclosing an outdoor covered patio, or adding a story (pop the top). Documents needed: 1. Permit Submittal checklist 2. Permit Process Guide 3. Electronic Submittal Instructions 4. Mechanical Design Form 5. Energy Compliance Form 6. Building Permit Application 7. Construction Waste Management Plan Other submittal options: Use the Multi -family Submittal Guide for more than 2 residential units built on a single lot. If the same residential building design will be constructed at least 3 times, submit as stock plan/master plan F�ort of rmit Submittal Checklist: Planning, Development & Transportation Services Community Development & Neighborhood Services 81 North Collegge Avenue Fort Collins, -CO 80524 970.416.2740 New Single Detached Family Homes, Duplexes, Townhomes, and Additions Incomolete or deferred submittals will not be accepted Required of Drawings depicting the scope of work X Building Permit Application X Plans must reflect current adopted codes and standards: www.fcgov.com/building/codes.php X Mechanical Design Form and Load Calcs Homeowner Affidavit (homeowner builders only) Energy Code Compliance Form X Plan Check Fee (Payment by check only) Additional fee is required for an F&F permit. Construction Waste Management Plan Form Ke—quife—d-Ur—awings Additional Requirements Stamped & Signed Drawings by a Colorado Licensed Engineer/Architect Separate Demo Permit: Required for Full or Partial demolition of exterior are required for: elements. All footing and foundation work Separate Solar Permit: Required for all new solar (new or altered). Architectural Drawings: Historic Preservation Review Existing Drawings showing pre -demo condition www.fcgov.com/historicpreservation Proposed Floor Plans with room labels and areas Alterations to, or Demolitions of buildings more than 50 years old will be reviewed for Historic Eligibility Exterior Elevations, Building Section, Details Townhomes only: Accessibility plan CRS 9-5 Grading Structural Drawings: WaterUtilitesEng@fcgov.com Sheer: wall bracing and method used, wind speed used, wind Grading plan may be required if impervious area on lot is greater than speed method, wind speed exposure. 350sf. Loads: Floor and roof loads used. Are you building In a Floodplain? Framing Plans: Floor, Roof, Girders and Headers httos://www.fcgov.com/utilities/what-we- do/stormwater/flooding/flood Alai n-m aps-docu m ents Connections and details. (provide stair details) Zoning: 281 N College / (970) 416-2745 Mechanical Load Calcs (required for new forced air systems including new Contact Zoning for questions on: Setbacks, easements, buildable area secondary systems for additions) per lot, and short term rentals. Manual J,D,S (ACCA approved only) zoning@fcgov.com Electrical Drawing Select Poudre Fire Authority: 102 Remington / (970)-416-2891 Outlets, lighting, panel, equipment. httos://www.00udre-fire.org/online-services Site Plan If using NFPA 13D,13R or 13 Fire Suppression Systems, a separate submittal is required through the Poudre Fire Authority website. Show distance from new work to property lines, and adjacent structures on the same lot. Fire Details Optional (new homes only, not allowed for additions) Submit for full permit with an additional F&F set Townhomes and Duplexes only: Fire separation details and fire sprinkler systems under P2904 must be submitted for review. F&F Set: Structural Foundation Plans (stamped), Underground plumbing and electric (for townhomes only). Applicant Name: Job Site Address: Phone: Email (Required):