Loading...
HomeMy WebLinkAbout4380 ZIEGLER RD - SPECIAL INSPECTIONS - 10/8/2019I{ BROADCOM CAFE RENOVATION 4380 ZIEGLER ROAD FT. COLLINS, CO 80525 OCTOBER 201,9 TESTING Complete PO BOX 27706 ADJUSTING Mechanical DENVER, CO. 80227 TABB CERTIFIED Balancing, Inc. FAX 303-972-7453 SYSTEM BALANCING PHONE 303-948-5429 BROADCOM CAFE RENOVATION 4380 ZIEGLER ROAD FT. COLLINS, CO 80525 OCTOBER 201,9 TESTING Complete PO BOX 27706 ADJUSTING Mechanical DENVER, CO. 80227 TABB CERTIFIED Balancing, Inc. FAX 303-972-7453 SYSTEM BALANCING PHONE 303-948-5429 COMPLETE MECHANICAL PROJECT BALANCING LOCATION FAN SYSTEM CONTRACTOR BROADCOM CAFE RENOVATION 4380 ZIEGLER ROAD KMUA-1 M-TECH MECHANICAL PAGE NO 13881-8 DATE 10-07-19 BALANCER A.S. SIZE REQUIRED TEST 1 TEST 2 TEST 3 FINAL OPENING PLAN kCT'I AREA VEL CFM VEL % VEL % VEL % VEL CFM % REMARKS KMUA-1-1 24/24 1.10 409 450 370 90 390 429 95 100% OPEN 2 24/24 1.10 409 450 370 90 390 429 95 100% OPEN 3 10/16 1.00 3382 3382 ERR 3415 3415 101 TOTAL 4282 4273 REMARKS ATPRAT c 4 Complete Mechanical Balancing, Inc. EQUIPMENT DATA A) PROJECT BROADCOM CAFE RENOVATION Page 13881-9 Date 10-07-19 Contract M-TECH Balance: A.S. UNIT NO. KMUA-2 PLAN LOC. MAKE CAPTIVE AIRE MODEL NO. A2-20D SER. NO. 3846222 RATING 3820 CFM © 0.50" E.S.P. INITIAL RPM DIRECT DRIVE FINAL RPM DIRECT DRIVE B) MOTOR WESTINGHOUSE HP. 3 RATED EFF/PF 89.5/N.G. TYPE ASGH PH. 3 RATED SPEED 1755 MEAS.VOLTS (L/L) 210-210-210 SF. 1.15 RATED VOLTS 230/460 INITIAL AMPS 8.1-8.2-8.1 FR. 182T RATED AMPS 8.6/4.3 MEAS.VOLTS (L/G) 121-121-121 S FAMPS NONE GIVEN FINAL AMPS 8.1-8.2-8.1 C) STARTER SIZE THERMALS (EXIST) AMP. RATING THERMALS (REQ'D) AMP. RATING OTHER VARIABLE FREQUENCY DRIVE D) DRIVEN SHEAVE X BORE DRIVER SHEAVE X BORE BELTS SIZE X NO. BELTS MOT. ADJ. IN/OUT CL. DIST. DRIVE CHANGE BELT CHANGE E) FILTERS IN -0.24 IN. OUT -0.30 IN. DROP -0.06 IN. HEAT COIL IN -0.30 IN. OUT -1.16 IN. DROP -0.86 IN. COOL COIL IN -1.16 IN. OUT -1.66 IN. DROP -0.50 IN. FAN IN -1.66 IN. OUT 0.56 IN. RISE 2.22 IN. F) PUMP IN PSI OUT PSI RISE PSI FT DEAD HEAD IN PSI OUT PSI RISE PSI FT G) REMARKS AREA= SQ. FT.X FPM= CFM FINAL: SQ. FT.X FPM= CFM COMPLETE MECHANICAL PROJECT BALANCING LOCATION BROADCOM CAFE RENOVATION PAGE NO 4380 ZIEGLER ROAD DATE FAN SYSTEM KMUA-2 CONTRACTOR M-TECH MECHANICAL 13881-10 10-07-19 BALANCER A.S. SIZE RE$UIRED TEST 1 TEST 2 TEST 3 FINAL OPENING PLAN OiCTI AREA VEL CFM VEL % VEL % VEL % VEL CFM % REMARKS KMUA-2-1 24/24 1.10 695 765 680 98 695 765 100 2 24/24 1.10 695 765 620 89 690 759 99 3 24/24 1.10 695 765 620 89 700 770 101 4 24/241 1.10 695 765 540 78 690 759 99 5 24/24 1.10 695 765 580 83 700 770 101 TOTAL 3825 3823 PAGE 13881 TESTING COMPLETE P.O. BOX 27706 ADJUSTING MECHANICAL DENVER, CO. 80227 SYSTEM BALANCING BALANCING, INC. FAX 303-761-1317 TABB CERTIFIED PHONE 303-948-5429 PROJECT LOCATION ARCHITECT MECHANICAL ENGINEER SHEETMETAL CONTRACTOR BALANCING CREW FLOW HOOD ANEMOMETER SPEED INDICATOR AMMETER / VOLTMETER INCLINED DRAFT GAGE MAGNEHELIC GAGE PRESSURE GAGE PRESSURE GAGE DIFFERENTIAL PYROMETER THERMOMETERS MICROMANOMETER GENERAL INFORMATION BROADCOM CAFE RENOVATION 4380 ZIEGLER ROAD, FT. COLLINS, CO 80525 M-TECH MECHANICAL A.STRUBLE DATE OCTOBER 2019 INSTRUMENTS USED ALNOR / SHORTRIDGE DAVIS TYPE LCA 6000 BIDDLE TYPE 9915 AMPROBE TYPE DIGITAL DWYER 0-0.25" 0-0.50" 400" 0-0.50" 0-1.0"_0-2.0" 0-4.0" 0-8.0" -30--+30 PSI 0-60 PSI 0-100 PSI BARCO 0-50" 0-100" 300" 500" 0-100, ALNOR FLUKE TYPE 52 ALNOR TYPE 530 5� ° _ ANS/ Anthony Suable O�ronuma�aera,vq. ec. TABS Supenlsm mees151e December 31. 2020 PROJECT ALTITUDE 5200'�`°-� FLOW HOOD CORRECT 1.10 APPLIED TO; AREA (K FACTOR) X VELOCITY STATIC PRESSURE CORRECTION 1.21 RECORDED PRESSURE READINGS ARE MEASURED X CORRECTED 6 COMPLETE MECHANICAL PAGE 13881-1 BALANCING, INC. AIR SYSTEM RECAP SHEET JOB: BROADCOM CAFE RENOVATION ZONE OR REQ'D ACT'L % OF FUNCTION UNIT NO. MAIN CFM CFM REQ'D HEAT REMARKS PAGE SUPPLY BCU-1 3000 3099 103 2-3 SUPPLY RH-135 1-8 5040 5185 103 4 SUPPLY RH-136 9-12 2160 2223 103 4 SUPPLY VAV-FA018 1-6 4200 4208 100 5 SUPPLY EX. VAV 7-11 3150 3241 103 5 SUPPLY EX.VAV 12-16 3600 3597 100 5 SUPPLY FCU-107 80 81 101 6 SUPPLY KMUA-1 1-3 4282 4273 100 7-8. SUPPLY KMUA-2 1-5 3825 3823 100 9-10 SUPPLY KMUA-3 1-3 2992 3008 101 11-12 TOTAL 32329 32738 101 EXHAUST KEF-1 4758 4609 97 13 EXHAUST. KEF-2 656 635 97 DIRECT DRIVE 14 EXHAUST KEF-3 3587 3550 99 15 EXHAUST KEF-4 3325 3318 100 16 EXHAUST EF-1 900 902 100 DIRECT DRIVE 17 EXHAUST EF-2 600 596 99 DIRECT DRIVE 18. TOTAL 13826 13610 98 WATER SYSTEM RECAP REQ'D ACT'L % OF GPM GPM REQ'D CHILL WTR FCU-107 - MUA-3 76.07 76.07 100 19 TOTS 76.07 76.07 100 HOT WTR FCU-107 - MUA-3 112.9 112.93 100 20 TOTAL 112.9 112.93 100 Complete Page 13881-2 Mechanical Date 09-12-19 Balancing, Inc. Contract M-TECH Balance: A.S. EQUIPMENT DATA A) PROJECT BROADCOM CAFE RENOVATION UNIT NO. BCU-1 PLAN LOC. MAKE PRICE MODEL NO. BCH-30 SER. NO. 1552474-002-001 RATING 3000 CFM @ 0.75" E.S.P. INITIAL RPM 965 FINAL RPM 965 B) MOTOR MARATHON HP. 3 RATED EFF/PF N.G./81 TYPE TS PH. 3 RATED SPEED 1725 MEAS.VOLTS (L/L) 210-210-210 SF. 1.15 RATED VOLTS 208-230/460 INITIAL AMPS 6.0-5.98-5.89 FR. 56HZ RATED AMPS 9.2-9.6/4.3 MEAS.VOLTS (L/G) 121-121-121 S F AMPS 9.8-9.0/4.5 FINAL AMPS 6.0-5.98-5.89 C) STARTER SIZE THERMALS (EXIST) AMP. RATING THERMALS (REQ-D) AMP. RATING OTHER VARIABLE FREQUENCY DRIVE D) DRIVEN AK84 SHEAVE X BORE H 1" DRIVER 1VP60 SHEAVE X BORE 7/8" BELTS A54 SIZE X NO. BELTS 1 MOT. ADJ. IN/OUT CL. DIST. DRIVE CHANGE NONE BELT CHANGE NONE E) FILTERS IN -0.16 IN. OUT -0.30 IN. DROP -0.14 IN. HEAT COIL IN IN. OUT IN. DROP IN. COOL COIL IN -0.30 IN. OUT -0.81 IN. DROP -0.51 IN. FAN IN -0.81 IN. OUT 0.37 IN. RISE 1.18 IN. F) PUMP IN PSI OUT PSI RISE PSI FT DEAD HEAD IN PSI OUT PSI RISE PSI FT G) REMARKS SET AT 55 HZ AREA= SQ. FT.X FPM= CFM FINAL: SQ. FT.X FPM= CFM COMPLETE MECHANICAL PROJECT BROADCOM CAFE RENOVATION PAGE NO BALANCING LOCATION 4380 ZIEGLER ROAD FAN SYSTEM 13CU-1 CONTRACTOR M-TECH MECHANICAL I17A 0� 13881-3 09-12-19 BALANCER A.S. SIZE REQUIRED TEST 1 TEST 2 TEST 3 FINAL OPENING PLANACrIAREA VEL CFM VEL % VE % VEL % VEL CFM % REMARKS BCU-1-1 34/12 2.53 296 750 377 127 310 784 105 2 34/12 2.53 296 750 400 135 305 772 103 3 34/12 2.53 296 750 357 120 310 784 105 4 34/12 2.53 296 750 300 101 300 759 101 100% OPEN TOTAL 3000 3099 REMARKS AIRRAi. COMPLETE MECHANICAL PROJECT LOCATION BROADCOM CAFE RENOVATION PAGE NO 13881-4 4380 ZIEGLER ROAD FAN SYSTEM RH-135 & RH-136 CONTRACTOR M-TECH MECHANICAL DATE 09-11-19 BALANCER A.S. INNEME MINI ' ®®® mm on 100% OPEN 1 2 MIMW 1 1 IM= 1® / / IM m .... Mmil 100%OPEN 1�_IM MmMwm- '-_-- -_ --.... --- 1-_-� --.... -_- MINE MM MEMO mMM MMlMM -��MMMMMMMI ..■-_- ME ME ME WIN ME M 1-_MN -- M 1-_---_IN ME 0--- 1 MIMM IM ME M��� � REMARKS COMPLETE MECHANICAL BALANCING PROJECT LOCATION FAN SYSTEM CONTRACTOR BROADCOM CAFE RENOVATION 4380 ZIEGLER ROAD EXISTING VAV'S M-TECH MECHANICAL PAGE NO DATE 13881-5 10-08-19 BALANCER A.S. I© �-� . 11 "/�.... • 1 •. .. sell *• 100% OPEN m-.... • . 1 .. ml 100% OPEN EMINE �ME ME ....MMlMMl M Mil MEN :: moll INDUT54yel:� ATR73AT Complete Page 13881-6 Mechanical Date 10-08-19 Balancing, Inc. Contract M-TECH Balance: A.S. EQUIPMENT DATA A) PROJECT BROADCOM CAFE RENOVATION UNIT NO. FCU-107 PLAN LOC. MAKE PRICE MODEL NO. FCH-1-182.02 SER. NO. 1552474-001-001 RATING 80 CFM ® 0.5" E.S.P. INITIAL RPM DIRECT DRIVE FINAL RPM DIRECT DRIVE B) MOTOR PIKA HP. 1 /4 RATED EFF/PF NONE GIVEN TYPE NONE GIVEN PH. 1 RATED SPEED 400-1800 MEAS.VOLTS (L/L) SF. NONE GIVEN RATED VOLTS 115/230 INITIAL AMPS 0.13 FR. NONE GIVEN RATED AMPS 3.5/2.3 MEAS.VOLTS (L/G) 210 S F AMPS NONE GIVEN FINAL AMPS 0.13 C) STARTER SIZE THERMALS (EXIST) AMP. RATING THERMALS (REQ'D) AMP. RATING OTHER BUILT IN OVERLOAD PROTECTION D) DRIVEN AK84 SHEAVE X BORE H 1" DRIVER 1 VP60 SHEAVE X BORE 7/8" BELTS A54 SIZE X NO. BELTS 1 MOT. ADJ. IN/OUT CL. DIST. DRIVE CHANGE NONE BELT CHANGE NONE E) FILTERS IN -0.01 IN. OUT -0.01 IN. DROP -0.01 IN. HEAT COIL IN 0.04 IN. OUT 0.40 IN. DROP 0.36 IN. COOL COIL IN 0.04 IN. OUT 0.35 IN. DROP 0.31 IN FAN IN -0.01 IN. OUT 0.40 IN. RISE 0.41 IN F) PUMP IN PSI OUT PSI RISE PSI FT DEAD HEAD IN PSI OUT PSI RISE PSI FT G) REMARKS AREA= 1.10 SQ. FT.X 73 FPM= 80 CFM FINAL: 1.10 Sg. FT.X 74 FPM= _ 81 CFM 102% Complete Mechanical Balancing, Inc. EQUIPMENT DATA A) PROJECT BROADCOM CAFE RENOVATION Page 13881-7 Date 10-07-19 Contrac, M-TECH Balance: A.S. UNIT NO. KMUA-1 PLAN LOC. MAKE CAPTIVE AIRE MODEL NO. A2-20D SER. NO. 3846222 — RATING 4282 CFM @ 0.5" E.S.P. INITIAL RPM DIRECT DRIVE B) MOTOR WESTINGHOUSE HP. 5 FINAL RPM RATED EFF/PF DIRECT DRIVE 89.5/N.G. TYPE ASGH PH. 3 RATED SPEED 1750 MEAS.VOLTS (L/L) 210-210-210 SF. 1.15 RATED VOLTS 230/460 INITIAL AMPS 8.8-8.7-8.8 FR. 184T RATED AMPS 13.6/6.80 MEAS.VOLTS (L/G) 121-121-121 S FAMPS NONE GIVEN FINAL AMPS C) STARTER 8.8-8.7-8.8 SIZE THERMALS (EXIST) AMP. RATING THERMALS (REQ'D) AMP. RATING OTHER VARIABLE FREQUENCY DRIVE D) DRIVEN SHEAVE X BORE DRIVER SHEAVE X BORE BELTS SIZE X NO. BELTS MOT. ADJ. IN/OUT CL. DIST. DRIVE CHANGE BELT CHANGE E) FILTERS IN -0.20 IN. OUT -0.27 IN. DROP -0.07 IN. HEAT COIL IN -0.27 IN. OUT -0.90 IN. DROP -0.63 IN. COOL COIL IN -0.90 IN. OUT -1.35 IN. DROP -0.45 IN. FAN IN -1.35 IN. OUT 0.60 IN. RISE 1.95 IN. F) PUMP IN PSI OUT PSI RISE PSI FT DEAD HEAD IN PSI OUT PSI RISE PSI FT G) REMARKS AREA= SQ. FT.X FPM= CFM FINAL: SQ. FT.X FPM= CFM