Loading...
HomeMy WebLinkAbout6708 SNOWDEN DR - DISCLOSURES - 12/4/2018BUILDING LEAKAGE TES 'i i TopBuild Home Services Colleen Locker 260 Jimmy Ann Drive J Daytona Beach, FL 32114 Eel :mail: colleen.locker@topbuild.com Website: www.environementsforliving.cor Green Your Home Date of Test: 12/4/2018 Test File: 6708 S'fiowdon Dr - Dahlia - Techtite Customer: Insignia Homes Technician: Colleen Fitz -Gerald Fred Cooke Project Number: 310 E 5th St Loveland, CO 80537 Building Address: Dahlia Phone: 970-379-7696 6708 Snowdon Dr Fort Collins, CO 80526 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates 1383 CFM50 (+/- 3.2 %) 2.17 ACH50 76.0 M2 LBL ELA @ 4 Pa Flow Coefficient (C) = 98.7 ( +/- 14.2 %) Exponent (n) = 0.675 ( +/- 0.041 ) Correlation Coefficient = 0.99815 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 V800537 Grre Yas Mangy Date of Test: 12/412018 Test File: 6708 Snowdon Dr - Dahlia - Techtite Building Information Location Climate Information Volume 38164 Surface Area Floor Area 3993 Height # of Bedrooms # of Occupants Year of Construction 2018 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 9876 Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 corm Horne Date of Test: 12/4/2018 Test File: 6708 Snowdon Dr - Dahlia - Techtite Depressurization Test: Environmental Data indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 68.0 30.0 5000.0 Data Points - Data Entered Manually (TT 4.0.52.3) Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -2.4 n/a n/a -14.0 -11.4 72.3 -18.3 -15.7 135.6 -22.8 -20.2 177.6 -30.1 -27.5 265.5 -40.2 -37.6 397.9 -50.4 -47.8 59.6 -61.2 -58.6 77.0 -71.8 -69.2 99.8 -2.8 n/a n/a Time Averaging Period: 10 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 506 487 -4.6 Ring B 691 664 5.0 Ring B 790 759 1.3 Ring B 964 927 0.4 Ring B 1178 1133 -0.7 Ring B 1395 1341 0.0 Ring A 1581 1520 -1.2 Ring A 1794 1725 0.2 Ring A Deviations from Standard RESNET Multi -Point Test - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 j� c G.raur Homo Date of Test: 12/4/2018 Test File: 6708 Snowdon Dr - Dahlia - Techtite 1{F�9j07 FO C' Comments House to Garage: -48.2 Pa