Loading...
HomeMy WebLinkAbout3050 SYKES DR - DISCLOSURES - 11/1/2018BUILDING LEAKAGE TEST GS Services, LTD. 309 Lincoln Court Fort Collins, CO 80524 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 11/1/2018 Test File: Hartford MOS - 3050 Comet Street - Edison - BD1 Technician: Paul Higman Project Number: Customer: Hartford Homes Building Address: 3050 Comet Street Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1049 CFM50 ( +/- 0.8 %) (50 Pa = 0.2 w.c.) 2.75 ACH50 2. Leakage Area: 57.7 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 84.4 ( +/- 5.8 %) Exponent (n) = 0.644 ( +/- 0.016 ) Correlation Coefficient = 0.99969 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/1/2018 Test File: Hartford MOS - 3050 Comet Street - Edison - BD1 Building Information Volume 22896 Surface Area Floor Area 2460 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory DG700 42530 1/22/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/1/2018 Test File: Hartford MOS - 3050 Comet Street - Edison - BD1 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 69.0 45.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.7 n/a n/a -61.2 -59.7 42.6 1184 1168 -0.6 Ring A -55.4 -53.9 37.5 1112 1097 -0.4 Ring A -49.0 -47.6 32.0 1030 1016 0.0 Ring A -43.6 -42.1 27.3 952 940 0.0 Ring A -37.8 -36.3 218.3 875 863 1.1 Ring B -31.5 -30.1 169.2 771 761 0.6 Ring B -25.5 -24.0 125.1 664 655 0.1 Ring B -19.6 -18.1 84.6 547 540 -0.9 Ring B -1.3 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/1/2018 Test File: Hartford MOS - 3050 Comet Street - Edison - BD1 Comments House WRT Garage = -48.0 Pa