Loading...
HomeMy WebLinkAbout6315 MEADOW GRASS CT - DISCLOSURES - 10/23/2018BUILDING LEAKAGE TEST Date of Test: 10/23/2018 Test File: 6315 Meadow Grass Court Technician: Jay Bundy Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 6315 Meadow Grass Court Fort Collins, Colorado 80528 Test Results at 50 Pascals: cfm50 Airflow 2452 (+/- 0.8 %) ACH50 2.63 cfm/ft² (Floor Area) 0.4756 cfm/ft² (Surface Area) 0.1999 Leakage Areas: 253.3 in² (+/- 5.4 %) Canadian EqLA @ 10 Pa or 0.0206 in²/ft² Surface Area 134.9 in² (+/- 8.5 %) LBL ELA @ 4 Pa or 0.0110 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 193.1 (+/- 13.3 %) Exponent (n) = 0.650 (+/- 0.034) Correlation Coefficient = 0.99894 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 400 500 600 700 800 900 1000 2000 3000 4000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/23/2018 Test File: 6315 Meadow Grass Court Building Information Volume (ft³) 55876 Surface Area: (ft²) 12265 Floor Area: (ft²) 5156 Height (ft) 30 Year of Construction 2018 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/23/2018 Test File: 6315 Meadow Grass Court Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 66.0 55.0 Post-Test 66.0 55.0 Average 66.0 55.0 5053.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.4 n/a n/a -65.0 -63.2 257.9 2850 2870 0.5 Ring A -60.0 -58.2 226.5 2675 2694 -0.4 Ring A -55.0 -53.2 202.0 2530 2548 -0.2 Ring A -50.0 -48.2 180.6 2395 2413 0.8 Ring A -45.0 -43.2 151.0 2195 2211 -0.8 Ring A -40.0 -38.2 128.6 2030 2044 -0.7 Ring A -35.0 -33.2 109.9 1880 1894 0.8 Ring A -2.2 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10/23/2018 Test File: 6315 Meadow Grass Court Comments Garage with Respect to House @50PA= 45.2 Pa