Loading...
HomeMy WebLinkAbout6227 FISHHAWK CT - DISCLOSURES - 6/28/2018BUILDING LEAKAGE TEST Date of Test: 6/28/2018 Technician: Todd Buckner Test File: 6227 Fishhawk Court Customer: Toll Brothers 10 Inverness E Dr Ste 125 Englewood, CO 80112 Phone 303-708-0730 Building Address: 6227 Fishhawk Court Fort Collins, Colorado 80528 Test Results 1. Airflow at 50 Pascals: 1644 CFM ( +/- 0.1 %) (50 Pa = 0.2 w.c.) 1.81 ACH 0.29 CFM per ft2 floor area 2. Leakage Areas: 401.7 in2 ( +/- 0.7 %) Canadian EqLA @ 10 Pa 348.8 in2 ( +/- 1.2 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.14 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 1049.3 ( +/- 1.8 %) Exponent (n) = 0.115 ( +/- 0.005 ) Correlation Coefficient = 0.99581 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 420.3 CFM 0.46 ACH 2. Estimated Design Infiltration Rate: Winter: 589.5 CFM 0.65 ACH Summer: 334.9 CFM 0.37 ACH 3. Recommended Whole Building Mechanical 0.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 6/28/2018 Test File: 6227 Fishhawk Court Building Conditions Inside Temperature: 70 deg F Heating Fuel: Gas Outside Temperature: 80 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 4.0 Volume: 54351 ft3 Ventilation Weather Factor: 0.87 Surface Area: 11357 ft2 Energy Climate Factor: 17.0 Floor Area: 5592 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage with Respect to House 46.3 @ 50pa BUILDING LEAKAGE TEST Page 3 Date of Test: 6/28/2018 Test File: 6227 Fishhawk Court Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -1.0 n/a +/- 0.00 -65.0 86.7 1675 1691 -0.0 Ring A -60.0 84.6 1655 1671 -0.3 Ring A -55.0 83.6 1645 1660 0.1 Ring A -50.0 82.0 1630 1645 0.4 Ring A -45.0 78.9 1600 1615 -0.3 Ring A -40.0 77.4 1585 1600 0.2 Ring A -35.0 74.5 1555 1570 -0.1 Ring A -1.4 n/a +/- 0.00