HomeMy WebLinkAbout6008 SAPLING CT - DISCLOSURES - 11/13/2018 (4)BUILDING LEAKAGE TEST Date of Test: 11/13/2018 Test File: 6008 Sapling Court TECTITE Technician: Burgess Construction Consultants, Inc. - Jay Bundy Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 6008 Sapling Court Fort Collins, Colorado 80528 Test Results at 50 Pascals: cfm50 Airflow 1054 (+/- 2.3 %) ACH50 2.02 cfm/ft² (Floor Area) 0.3750 cfm/ft² (Surface Area) 0.1312 Leakage Areas: 99.5 in² (+/- 14.7 %) Canadian EqLA @ 10 Pa or 0.0124 in²/ft² Surface Area 50.4 in² (+/- 23.5 %) LBL ELA @ 4 Pa or 0.0063 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 66.8 (+/- 36.8 %) Exponent (n) = 0.705 (+/- 0.096) Correlation Coefficient = 0.99303 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/13/2018 Test File: 6008 Sapling Court TECTITE Building Information Volume (ft³) 31313 Surface Area: (ft²) 8034 Floor Area: (ft²) 2811 Height (ft) 11 Year of Construction 2018 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/13/2018 Test File: 6008 Sapling Court TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 33.0 Post-Test 70.0 33.0 Average 70.0 33.0 4737.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.7 n/a n/a -65.0 -61.6 481.7 1295 1248 2.2 Ring B -60.0 -56.6 399.2 1180 1137 -1.1 Ring B -55.0 -51.6 346.5 1100 1060 -1.6 Ring B -50.0 -46.6 321.5 1060 1021 1.9 Ring B -45.0 -41.6 246.9 930 896 -3.1 Ring B -40.0 -36.6 222.9 884 852 0.8 Ring B -35.0 -31.6 181.8 799 770 1.1 Ring B -4.2 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/13/2018 Test File: 6008 Sapling Court TECTITE Comments Garage with Respect to House 45.0 Pa