Loading...
HomeMy WebLinkAbout2275 CUTTING HORSE DR - DISCLOSURES - 12/6/2018 (4)BUILDING LEAKAGE TEST GS Services, LTD. 2000 S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 12/6/2018 Test File: Bellisimo - 2275 Cutting Horse Dr Unit 2 - BDma Technician: Nick Hiseler Project Number: Customer: Bellisimo Inc Building Address: 2275 Cutting Horse Unit 2 Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 672 CFM50 ( +/- 0.7 %) (50 Pa = 0.2 w.c.) 2.80 ACH50 2. Leakage Area: 36.9 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 22.8 ( +/- 5.5 %) Exponent (n) = 0.865 ( +/- 0.015 ) Correlation Coefficient = 0.99985 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/6/2018 Test File: Bellisimo - 2275 Cutting Horse Dr Unit 2 - BDma Building Information Volume 14372 Surface Area Floor Area 1520 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/6/2018 Test File: Bellisimo - 2275 Cutting Horse Dr Unit 2 - BDma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 77.0 32.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.7 n/a n/a -60.5 -60.7 200.6 839 803 1.1 Ring B -53.5 -53.7 157.8 745 713 -0.2 Ring B -48.7 -48.9 132.8 684 655 -0.6 Ring B -41.0 -41.2 99.9 594 568 0.1 Ring B -36.9 -37.1 81.8 538 515 -0.8 Ring B -32.2 -32.4 65.3 481 460 -0.2 Ring B -26.3 -26.5 311.7 407 390 0.5 Ring C -17.9 -18.1 163.2 292 279 0.2 Ring C 2.1 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/6/2018 Test File: Bellisimo - 2275 Cutting Horse Dr Unit 2 - BDma Comments House WRT Garage = -46.1 Pa