Loading...
HomeMy WebLinkAbout2263 YEARLING DR - DISCLOSURES - 8/2/2018BUILDING LEAKAGE TEST GS Services, LTD. 309 Lincoln Ct Fort Collins, CO 80524 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive East Unit - BD1 Technician: Paul Higman Project Number: B1607764 Customer: Bellisimo 3702 Manhattan Avenue, #201 Fort Collins, CO 80525 Building Address: 2263 Yearling Drive East Unit Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 681 CFM50 ( +/- 4.0 %) (50 Pa = 0.2 w.c.) 2.85 ACH50 2. Leakage Area: 37.4 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 48.8 ( +/- 26.9 %) Exponent (n) = 0.674 ( +/- 0.075 ) Correlation Coefficient = 0.99379 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 39.1 CFM 0.16 ACH 2. Estimated Design Infiltration Rate: Winter: 62.0 CFM 0.26 ACH Summer: 41.1 CFM 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive East Unit - BD1 Building Information Volume 14309 Surface Area Floor Area 1522 Height 19 # of Bedrooms 3 # of Occupants Year of Construction 2018 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory DG700 42530 1/22/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive East Unit - BD1 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 85.0 71.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 6.4 n/a n/a -45.7 -52.6 139.1 700 715 1.4 Ring B -46.7 -53.6 130.6 678 693 -2.9 Ring B -40.3 -47.2 117.7 644 658 0.4 Ring B -34.1 -41.0 101.6 599 612 2.7 Ring B -31.0 -37.9 84.6 547 559 -1.1 Ring B -20.2 -27.1 59.5 459 469 4.2 Ring B -16.7 -23.6 40.5 379 387 -5.6 Ring B -9.6 -16.5 28.7 320 327 1.3 Ring B 7.4 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive East Unit - BD1 Comments House WRT Garage = -46.2 Pa BUILDING LEAKAGE TEST GS Services, LTD. 309 Lincoln Ct Fort Collins, CO 80524 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive West Unit - BD1ma Technician: Paul Higman Project Number: B1607764 Customer: Bellisimo 3702 Manhattan Avenue, #201 Fort Collins, CO 80524 Building Address: 2263 Yearling Drive West Unit Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 707 CFM50 ( +/- 3.2 %) (50 Pa = 0.2 w.c.) 2.96 ACH50 2. Leakage Area: 38.9 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 23.0 ( +/- 20.8 %) Exponent (n) = 0.876 ( +/- 0.058 ) Correlation Coefficient = 0.99777 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 40.6 CFM 0.17 ACH 2. Estimated Design Infiltration Rate: Winter: 64.4 CFM 0.27 ACH Summer: 42.7 CFM 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive West Unit - BD1ma Building Information Volume 14309 Surface Area Floor Area 1522 Height 19 # of Bedrooms 3 # of Occupants Year of Construction 2018 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory DG700 42530 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive West Unit - BD1ma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 83.0 73.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 8.3 n/a n/a -50.0 -56.8 153.1 734 785 -0.7 Ring B -48.2 -55.0 142.4 708 758 -1.4 Ring B -40.6 -47.4 109.3 621 664 -1.5 Ring B -32.5 -39.3 83.0 542 580 1.3 Ring B -25.1 -31.9 61.0 465 498 4.3 Ring B -20.3 -27.1 44.3 397 425 2.7 Ring B -15.3 -22.1 27.4 313 335 -3.2 Ring B -11.0 -17.8 134.1 264 282 -1.3 Ring C 5.3 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/2/2018 Test File: Bellisimo - 2263 Yearling Drive West Unit - BD1ma Comments House WRT Garage = -46.4 Pa Planning, Development & Transportation Services Community Development & Neighborhood Services Updated 03/01/2014 Simulated Performance Alternative (SPA) Cover Sheet 1. Submittal and Rating Type  Stock Plan Permit – Projected Worst-Case Rating Builder Model: ________________________________  Lot-specific Permit - Projected Rating Address: ____________________________________  Completed Home – Confirmed Rating Address: ____________________________________ 2. Data Required for All SPA Ratings Builder: ____________________________________ Rating Firm: _________________________________ Energy Rater: ________________________________ Date: _______________________________________ Duct Location Inputs (REM/Rate “Duct Systems” page) Duct Location Supply Return % Area R-Value % Area R-Value Thermal Envelope Clarification Component Thermal Location Crawl space  N/A  Inside  Outside Attic  N/A  Inside  Outside Bonus room  N/A  Inside  Outside Ductwork adjacent to garage  N/A  Inside  Outside Other:  N/A  Inside  Outside 3A. Additional Information for Stock Plan Permit – Projected Worst-Case Rating Worst-Case Configuration Front elevation orientation Foundation type(s) Options included  Attach REM/Rate 2012 IECC Energy Cost Compliance report showing “PASS”  Attach REM/Rate Energy Code Inspection Checklist 3B. Additional Information for Lot-Specific Permit – Projected Rating  Attach REM/Rate 2012 IECC Energy Cost Compliance report showing “PASS”  Attach REM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home – Confirmed Rating  Attach REM/Rate 2012 IECC Energy Cost Compliance report showing “PASS” (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.)  Attach REM/Rate Home Energy Rating Certificate Utility Rates Energy Source Service Charge Variable Rate Electricity $/mo $/kWh Natural gas $/mo $/therm See Residential New Construction SPA Guide Planning, Development & Transportation Services Community Development & Neighborhood Services Updated 03/01/2014 Simulated Performance Alternative (SPA) Cover Sheet 1. Submittal and Rating Type  Stock Plan Permit – Projected Worst-Case Rating Builder Model: ________________________________  Lot-specific Permit - Projected Rating Address: ____________________________________  Completed Home – Confirmed Rating Address: ____________________________________ 2. Data Required for All SPA Ratings Builder: ____________________________________ Rating Firm: _________________________________ Energy Rater: ________________________________ Date: _______________________________________ Duct Location Inputs (REM/Rate “Duct Systems” page) Duct Location Supply Return % Area R-Value % Area R-Value Thermal Envelope Clarification Component Thermal Location Crawl space  N/A  Inside  Outside Attic  N/A  Inside  Outside Bonus room  N/A  Inside  Outside Ductwork adjacent to garage  N/A  Inside  Outside Other:  N/A  Inside  Outside 3A. Additional Information for Stock Plan Permit – Projected Worst-Case Rating Worst-Case Configuration Front elevation orientation Foundation type(s) Options included  Attach REM/Rate 2012 IECC Energy Cost Compliance report showing “PASS”  Attach REM/Rate Energy Code Inspection Checklist 3B. Additional Information for Lot-Specific Permit – Projected Rating  Attach REM/Rate 2012 IECC Energy Cost Compliance report showing “PASS”  Attach REM/Rate Energy Code Inspection Checklist 3C. Additional Information for Completed Home – Confirmed Rating  Attach REM/Rate 2012 IECC Energy Cost Compliance report showing “PASS” (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.)  Attach REM/Rate Home Energy Rating Certificate Utility Rates Energy Source Service Charge Variable Rate Electricity $/mo $/kWh Natural gas $/mo $/therm See Residential New Construction SPA Guide 2015 IECC Energy Cost Compliance Property Bellisimo Construction 2263 Yearling Dr East Unit Fort Collins, CO 80525 Weather:Ft. Collins, CO 2263 Yearling Dr East Unit Bellisimo BuckingHorse-2263 Organization GS Services LTD 970-449-1612 Paul Higman Builder Bellisimo Construction HERS 2018-08-28 Rater ID:6784592 REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Annual Energy Cost $/yr 2015 IECC As Designed Heating 295 286 Cooling 116 96 Water Heating 124 124 SubTotal - Used to Determine Compliance 534 506 Mechanical Ventilation Fan 18 21 Lights & Appliances (minus MechVent) 533 522 Photovoltaics -0 -0 Service Charge 240 240 Total 1325 1289 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 5.3%. Name Paul Higman Signature Organization GS Services LTD Date 29 August 2018 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 2263 Yearling Dr East Unit, Fort Collins, CO by Bellisimo Construction exceeds the minimum requirements for the 2015 International Energy Conservation Code The 2015 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Building Features Ceiling Flat R-49.0 Duct NA Sealed Attic: NA Duct Leakage to Outside: 25.00 CFM @ 25 Pascals Vaulted Ceiling NA Total Duct Leakage: 48.00 CFM @ 25 Pascals Above Grade Walls R-21.0 Infiltration: Htg: 681 Clg: 681 CFM50 Foundation Walls NA Window U-Value: 0.320, SHGC: 0.310 Exposed Floor R-38.0 Heating Fuel-fired air distribution, Natural gas, 95.0 AFUE. Slab R-10.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.62 EF, 50.0 Gal. Name Paul Higman Signature Organization GS Services LTD Date 29 August 2018 2015 IECC Energy Cost Compliance Property Bellisimo Construction 2263 Yearling Dr West Unit Fort Collins, CO 80525 Weather:Ft. Collins, CO 2263 Yearling Dr West unit Bellisimo BuckingHorse-2263 Organization GS Services LTD 970-449-1612 Paul Higman Builder Bellisimo Construction HERS 2018/08/28 Rater ID:6784592 REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Annual Energy Cost $/yr 2015 IECC As Designed Heating 295 300 Cooling 116 94 Water Heating 124 124 SubTotal - Used to Determine Compliance 534 518 Mechanical Ventilation Fan 18 21 Lights & Appliances (minus MechVent) 533 522 Photovoltaics -0 -0 Service Charge 240 240 Total 1325 1302 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 3.0%. Name Paul Higman Signature Organization GS Services LTD Date 29 August 2018 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 2263 Yearling Dr West Unit, Fort Collins, CO by Bellisimo Construction exceeds the minimum requirements for the 2015 International Energy Conservation Code The 2015 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Building Features Ceiling Flat R-49.0 Duct NA Sealed Attic: NA Duct Leakage to Outside: 28.00 CFM @ 25 Pascals Vaulted Ceiling NA Total Duct Leakage: 52.00 CFM @ 25 Pascals Above Grade Walls R-21.0 Infiltration: Htg: 707 Clg: 707 CFM50 Foundation Walls NA Window U-Value: 0.320, SHGC: 0.310 Exposed Floor R-38.0 Heating Fuel-fired air distribution, Natural gas, 95.0 AFUE. Slab R-10.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.62 EF, 50.0 Gal. Name Paul Higman Signature Organization GS Services LTD Date 29 August 2018