Loading...
HomeMy WebLinkAbout444 ZEPPELIN WAY - DISCLOSURES - 12/28/2017BUILDING LEAKAGE TEST Date of Test: 12/28/2017 Test File: 444 Zeppelin Way CalAtlantic V2.2 Multi Point Tectite(1) Technician: Zach Kimbrough - EnergyLogic, Inc. Project Number: 48164 Customer: CalAtlantic Group, Inc. Building Address: 444 Zeppelin Way Ft. Collins, CO 80521 Test Results 1. Airflow at 50 Pascals: 909 CFM50 ( +/- 2.2 %) (50 Pa = 0.2 w.c.) 2.88 ACH50 2. Leakage Area: 50.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 23.7 ( +/- 37.7 %) Exponent (n) = 0.932 ( +/- 0.099 ) Correlation Coefficient = 0.99440 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 53.0 CFM 0.17 ACH 17.7 CFM per person 2. Estimated Design Infiltration Rate: Winter: 99.7 CFM 0.32 ACH Summer: 62.6 CFM 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 35.7 CFM Base Rate: 42.4 CFM Infiltration Credit: <6.7 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/28/2017 Test File: 444 Zeppelin Way CalAtlantic V2.2 Multi Point Tectite(1) Building Information Volume 18976 Surface Area Floor Area 1985 Height 20 # of Bedrooms 2 # of Occupants 3 Year of Construction 2017 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 26986-7 8/2/2010 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/28/2017 Test File: 444 Zeppelin Way CalAtlantic V2.2 Multi Point Tectite(1) Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 70.0 29.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -5.4 n/a n/a -64.8 -59.1 36.4 1097 1046 -1.6 Ring A -61.6 -55.9 33.6 1055 1006 -0.3 Ring A -57.3 -51.6 29.6 991 946 0.9 Ring A -54.4 -48.8 27.0 947 904 1.8 Ring A -48.7 -43.0 192.2 821 784 -0.8 Ring B -44.2 -38.5 163.8 759 724 1.6 Ring B -40.9 -35.2 141.0 704 672 2.4 Ring B -40.1 -34.5 119.4 649 619 -3.7 Ring B -5.9 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/28/2017 Test File: 444 Zeppelin Way CalAtlantic V2.2 Multi Point Tectite(1) Comments Connection to: Garage: -48.9 Pa Mechanicals: -50 Pa