Loading...
HomeMy WebLinkAbout615 E PLUM ST - DISCLOSURES - 12/18/2017BUILDING LEAKAGE TEST Date of Test: 12/18/2017 Test File: 615 E Plum tectite Passing Technician: Greydon Studer Project Number: Customer: Building Address: 615 E Plum Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1571 CFM50 ( +/- 0.6 %) (50 Pa = 0.2 w.c.) 2.95 ACH50 2. Leakage Area: 86.4 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 131.6 ( +/- 4.1 %) Exponent (n) = 0.634 ( +/- 0.012 ) Correlation Coefficient = 0.99983 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/18/2017 Test File: 615 E Plum tectite Passing Building Information Volume 31939 Surface Area Floor Area 3480 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/18/2017 Test File: 615 E Plum tectite Passing Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 70.0 51.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.7 n/a n/a -60.0 -59.4 96.3 1763 1754 0.1 Ring A -54.0 -53.4 84.1 1650 1641 0.2 Ring A -48.0 -47.4 71.9 1529 1521 0.1 Ring A -42.0 -41.4 60.1 1401 1394 -0.0 Ring A -36.0 -35.4 48.1 1257 1250 -0.9 Ring A -30.0 -29.4 38.5 1128 1122 -0.0 Ring A -24.0 -23.4 29.1 984 979 0.8 Ring A -18.0 -17.4 185.4 807 803 -0.2 Ring B -0.5 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/18/2017 Test File: 615 E Plum tectite Passing Comments None