Loading...
HomeMy WebLinkAbout451 STOUT ST - DISCLOSURES - 12/1/2017 (6)BUILDING LEAKAGE TEST GS Services, LTD. 2000 S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 12/1/2017 Test File: Hartford Homes TV - 451 Stout St - Laurel - BD1 Technician: Nick Hiseler Project Number: Customer: Hartford Homes Building Address: 451 Stout St Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 867 CFM50 ( +/- 0.8 %) (50 Pa = 0.2 w.c.) 2.62 ACH50 2. Leakage Area: 47.7 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 55.3 ( +/- 5.7 %) Exponent (n) = 0.703 ( +/- 0.016 ) Correlation Coefficient = 0.99975 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/1/2017 Test File: Hartford Homes TV - 451 Stout St - Laurel - BD1 Building Information Volume 19815 Surface Area Floor Area 1416 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 Default Micromanometer Energy Conservatory DG700 19028 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/1/2017 Test File: Hartford Homes TV - 451 Stout St - Laurel - BD1 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 62.0 50.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.5 n/a n/a -62.4 -60.4 29.8 994 1001 1.1 Ring A -54.8 -52.8 224.7 888 894 -0.8 Ring B -49.9 -48.0 195.4 828 834 -0.9 Ring B -43.2 -41.2 160.7 752 757 0.0 Ring B -37.1 -35.1 129.5 675 680 0.6 Ring B -31.4 -29.4 99.9 594 598 0.2 Ring B -25.4 -23.4 72.1 505 509 0.0 Ring B -19.9 -17.9 49.1 418 421 -0.1 Ring B -2.4 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/1/2017 Test File: Hartford Homes TV - 451 Stout St - Laurel - BD1 Comments House WRT Garage = -47.3 Pa