Loading...
HomeMy WebLinkAbout229 OSIANDER ST - DISCLOSURES - 10/27/2017QnergyLogic analysis. Insight. answers. BUILDING LEAKAGE TEST I WbA 3 d 3' M Date of Test: 10/27/2017 Customer: Erik Haagenson Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve 4. Test Settings: 5. Accuracy Level Test File: 229 Multi Point Tectite Technician: Neal Girard — EnergyLogic, Project Number: 48414 Building Address: 229 Osiander St Ft. Collins, CO 80524 279 CFM50 (+/- 0.8%) 1.44 ACH50 15.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 18.6 (+/- 13.4%) Exponent (n) = 0.690 (+/- 0.026) Correlation Coefficient = 0.99929 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimate 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 16.1 CFM 0.16 ACH 8.1 CFM per person Winter: 30.4 CFM Summer: 19.1 CFM 0.30 ACH 0.19 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 19.4 CFM Base Rate: 21.2 CFM atiUl117 1.27prl QnergyLogic BUILDING LEAKAGE TEST Page 2 Of 4 Date of Test: 10/27/2017 Test File: 245 Osiander St - Haagenson - MP Tectite (2) Building information Location Climate Information Volume ; 6131 Surface Area 2389 Floor Area 622 Height 20 fl of Bedrooms _ _ 1 # of Occupants Year of Construction Wind Shield —� 2 A 2015 M Heating and Cooling Coat and Efficiency Information _Heating Fuelww^„ Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost { Cooling SEER i Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days _ 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph _ Design Summer Wind Speed 9.4 mph Design Winter Temp DiN 73 deg F Design Summer Temp Dii% 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default j Micromanometer Energy Conservatory OG700 12830-7 3/22/2013 QnergyLogic BUILDING LEAKAGE TEST Page 3 Of 4 Date of Test: 10/27/2017 Test File: 245 Osiander St - Haagenson - MP Tectite (2) Depressurization Test: Environmental Data -Y� Indoor Temperature {°Fj 'T Outdoor Temperature (°F) Altitude (ft) 1 I 68.0 55.0 5000.0 Date Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.9 n/a n/a -64.0 -63.0 195.8 321 324 -0.3 fling C -59.7 -58.6 177.3 305 308 -0.4 Ring C -54.5 -53.4 159A 289 292 0.7 Ring C -51.0 -49.9 143.6 273 276 -0.2 Ring C -45.9 -44.9 127.3 257 260 1.0 Ring C -43.4 -42.3 114.1 243 245 -0.5 Ring C -39.2 -38.1 100.4 228 230 0.1 Ring C -34.6 -33.6 83.9 208 210 -0.3 Ring C -1.2 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters im . -� QnergyLogic ,.e�,,,.. ��.;a�,. e....,,. BUILDING LEAKAGE TEST Page 3 Of 4 Date of Test: 10/27/2017 Test File: 245 Osiander St- Haagenson - MP Tectite (2) Comments Connections to: Garage =-45.3 Pa Mechanicals = -50