HomeMy WebLinkAbout4700 LADY MOON DR - SPECIAL INSPECTIONS - 9/11/2017FJP7- G ENGINEERING, INC. PO BOX 810. SEDALIA CO Q03) 688-9044 GENERAL INFORMATION PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION LOCATION FORT COLLINS, COLORADO ELEVATION 5000, ARCHITECT DLR GROUP MECH. ENG. DLR GROUP CONTRACTOR US ENGINEERING ��6 BAL. CREW ERIC CONNER DATE AUGUST,2017 JPG JOB # 3525 INSTRUMENTS USED CALIBRATION DATE: Feb 16, 2017 AMPMETER/VOLTMETER FLuke 324 4152637 ANEMOMETER TSI/ALNOR RVA-801 JPG-17 PRESSURE GAGE -DIFFER SHORTRIDGE HDM-300 247987 SPEED INDICATOR Biddle 9920 786293 VELTMETER Shortridge ADM-870 M98083 METHOD OF BALANCE Supply Diffusers are read with a capture hood using a Shortridge Air Data Meter. Exhaust and return inlet registers read with Shortridge Air Data Meter and Flow Hood. DDC Velocity sensors on VAV and FPB boxes are calibrated to actual flow measured with Air Data Meter. Heating water flow rates are measured with a differential pressure meter on the installed flow elements. \\\\\111H111111711pq!!!0 I)a *��G�P®eRo'���yw,, 3�° en ine as 11,661 Weam '0 Pi�os/ CMIMOPWR Q. CONNER � ron!° tim 30TIFICiNnON 43 Arta un � Exp. 3/31/le ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM / -AH 1�A LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM VAV1 A.07 7 24X24 24X24 1.0 80 80 83 83 8 24X24 24X24 1.0 80 80 84 84 r- TOTAL 790 788 VAV1 A.08 1 24X24 24X24 1.0 80 80 78 78 9 48X24 48X24 1.0 160 160 152 152 3 48X24 48X24 1.0 160 160 160 160 4 24X24 24X24 1.0 70 70 69 69 5 24X24 24X24 1.0 80 80 83 83 TOTAL 550 542 VAV1 A.09 1 24X24 24X24 1.0 105 105 104 104 2 24X24 24X24 1.0 105 105 107 107 3 24X24 24X24 1.0 115 115 110 110 4 24X24 24X24 1.0 115 115 117 117 TOTAL 440 438 Pal 9 of 21 ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM �'AHU 1A LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM VAV1A.10 1 24X24 24X24 1.0 65 65 67 67 2 24X24 24X24 1.0 50 50 48 48 3 24X24 24X24 1.0 75 75 77 77 4 24X24 24X24 1.0 75 75 72 72 5 24X24 24X24 1.0 75 75 80 80 6 24X24 24X24 1.0 75 75 78 78 7 24X24 24X24 1.0 75 75 71 71 8 24X24 24X24 1.0 75 75 74 74 9 24X24 24X24 1.0 75 75 71 71 10 24X24 24X24 1.0 75 75 71 71 TOTAL 715 709 VAV1A.11 1 24X24 24X24 1.0 75 75 76 76 2 24X24 24X24 1.0 75 75 78 78 TOTAL 150 154 Pa( 1 of 21 ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM A`HU-1A/ LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM VAV1A.12 1 12X12 12X12 1.0 315 315 322 322 TOTAL 315 322 Pa( 2 of 21 wf ENGINEERING VAV RECAP SHEET PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM: EXISTING AHU BOX # ADD # MAX MIN HEAT SIZE MULT REMARKS VAV'S XVAV1-2 20 350 240 240 6" 0.67 XVAV1-7 21 350 350 350 6" 0.70 XVAV1-8 19 300 100 100 6" 0.65 TOTAL 1000 690 690 Page 13 of 21 ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM EXISTING AHU LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM XVAV1-2 1 24/8 24/8 1.0 110 110 109 109 2 24/8 24/8 1.0 80 80 75 75 3 24/8 24/8 1.0 40 40 44 44 4 24/8 24/8 1.0 120 120 120 120 TOTAL 350 348 XVAV1-7 1 24/10 24/10 1.0 300 300 309 309 2 12X12 12X12 1.0 50 50 50 50 TOTAL 350 359 XVAV1-8 1 24/10 24/10 1.0 300 300 296 296 TOTAL 300 296 P2 '4of21 JENGINEERING EQUIPMENT DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION EQUIPMENT INFORMATION UNIT # EF-12 MAKE GREENHECK MODEL # CUE-099-VG-4-X SERIAL # 14969881 RATING 350 CFM @ 0.50" ESP MOTOR DATA MAKE GREENHECK H.P. 1/4 PF/EFF NOT GIVEN / NOT GIVEN TYPE NOT GIVEN PH. 1 RATED SPEED 300-1725 MEAS. VOLTS 120 SF. NOT GIVEN RATED VOLTS 115 MEAS. AMPS 2.6 FR. NOT GIVEN RATED AMPS 3.5 STARTER DATA MAKE NONE MODEL SIZE ENCLOSURE CLASS THERMALS (EXISTING) AMP RATING THERMALS (REQUIRED) AMP RATING OTHER BUILT IN OVERLOAD DRIVE DATA DRIVEN SHEAVE DIRECT DRIVE BORE DRIVER SHEAVE BORE BELT SIZE NO. BELTS TURNS TO MAX MOTOR ADJUST -INCHES DRIVE CHANGE BELT CHANGE INITIAL/FINAL RPM / FINAL AMPS 2.6 PRESSURE INFORMATION IN JOUT Remarks: REQUIRED = 350 CFM FINAL = 356 CFM. FAN SPEED SET Page 15 of 21 ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM EXHAUST LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM EF-12 1 12X12 12X12 1.0 100 100 99 99 2 12X12 12X12 1.0 100 100 99 99 3 12X12 12X12 1.0 100 100 105 105 4 24X12 24X12 1.0 50 50 53 53 TOTAL 350 356 P2 16of21 ENGINEERING TABLE OF CONTENTS Item Sheet Number CoverPage.................................................................................................................................................. I Tableof Contents........................................................................................................................................2 Equipment(Air) - AHU-IA (SUPPLY)......................................................................................................3 Equipment(Air) - AHU-IA (RETURN).....................................................................................................4 RectDuct Traverse - AHU-1 OSA..............................................................................................................5 VAVRecap - AHU- I A / VAV'S................................................................................................................6 Air Balance - AHU-IA / VAV IA.01.........................................................................................................7 Air Balance - AHU- I A / VAV I A.02.........................................................................................................7 AirBalance - AHU- I A / VAV I A.03.........................................................................................................8 Air Balance - AHU- I A / VAV 1 A.04.........................................................................................................8 Air Balance - AHU-1 A / VAV I A.05.........................................................................................................8 Air Balance - AHU-1 A / VAV 1 A.06.........................................................................................................9 Air Balance - AHU- I A / VAV 1A.07.........................................................................................................9 Air Balance - AHU- I A / VAV 1 A.08.........................................................................................................10 Air Balance - AHU-I A / VAV 1A.09.........................................................................................................10 Air Balance - AHU-IA / VAV IA.10.........................................................................................................I I Air Balance - AHU-1 A / VAV IA.I 1.........................................................................................................I 1 Air Balance - AHU-IA / VAV IA.12.........................................................................................................12 VAV Recap - EXISTING AHU / VAVS...................................................................................................13 Air Balance - EXISTING AHU / XVAV 1-2..............................................................................................14 Air Balance - EXISTING AHU / XVAV 1-7..............................................................................................14 Air Balance - EXISTING AHU / XVAV 1-8..............................................................................................14 Equipment(Air) - EF-12..............................................................................................................................15 Air Balance - EXHAUST / EF-12..............................................................................................................16 Water Balance - HOT WATER / HOT WATER.......................................................................................17 Equipment(Water) - PHP-AHU-IA ............................................................................................................20 Water Balance - CHILLED WATER / AHU- I A.......................................................................................21 Page 2of21 ENGINEERING EQUIPMENT DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION EQUIPMENT INFORMATION UNIT # AHU-1A (SUPPLY) MAKE TEMTROL MODEL # ITF-RSA-RDHRE 15 SERIAL # B000403-00 RATING 8,400 CFM @ 2.0" ESP MOTOR DATA MAKE BALDOR X 2 MOTORS H.P. 7.5 PF/EFF 90 / 91 TYPE B000403-00 PH. 3 RATED SPEED 3525 MEAS. VOLTS VFD - 460 @ 60 HZ SF. 1.15 RATED VOLTS 230/460 MEAS. AMPS VFD - 8.8 @ 47 HZ FR. 213TZ RATED AMPS 19-17.2/8.6 STARTER DATA MAKE HVAC-VFD MODEL SIZE ENCLOSURE CLASS THERMALS (EXISTING) AMP RATING THERMALS (REQUIRED) AMP RATING OTHER DRIVE DATA DRIVEN SHEAVE DIRECT DRIVE BORE DRIVER SHEAVE BORE BELT SIZE NO. BELTS TURNS TO MAX MOTOR ADJUST -INCHES DRIVE CHANGE BELT CHANGE INITIAL/FINAL RPM / FINAL AMPS VFD - 8.8 @ 47 HZ PRESSURE INFORMATION BLENDER IN -0.13 OUT -0.18 DROP 0.05 " FILTER IN -0.18 OUT NO ACCESS - " HEATING COIL IN NO ACCESS OUT -0.36 - " COOLING COIL IN -0.36 OUT -0.73 DROP 0.37 " FAN IN -0.73 OUT 2.18 RISE 2.91 " FINAL FILTER IN 2.18 OUT 1.84 DROP 0.34 " Remarks: UNIT FINALLED AT MINIMUM (26% - 2,200 CFM) OUTSIDE AIR WITH ALL VAV'S CALLING FOR MAX COOLING. DUCT STATIC IS MAINTAINING 1.40". DUCT STATIC SETPOINT IS 1.40" Page 3 of 21 ENGINEERING EQUIPMENT DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION EQUIPMENT INFORMATION UNIT # AHU-1A (RETURN) MAKE TEMTROL MODEL # ITF-RSA-RDHRE 15 SERIAL # B000403-00 RATING 8,100 CFM @ 0.50" ESP MOTOR DATA MAKE BALDOR X 2 MOTORS H.P. 2 PF/EFF 82 / 86.5 TYPE B000403-00 PH. 3 RATED SPEED 1725 MEAS. VOLTS VFD - 460 @ 60 HZ SF. 1.15 RATED VOLTS 230/460 MEAS. AMPS VFD - 2.7 @ 35 HZ FR. 145T RATED AMPS 5.7-5.4/2.7 STARTER DATA MAKE HVAC-VFD MODEL SIZE ENCLOSURE CLASS THERMALS (EXISTING) AMP RATING THERMALS (REQUIRED) AMP RATING OTHER DRIVE DATA DRIVEN SHEAVE DIRECT DRIVE BORE DRIVER SHEAVE BORE BELT SIZE NO. BELTS TURNS TO MAX MOTOR ADJUST -INCHES DRIVE CHANGE BELT CHANGE INITIAL/FINAL RPM / FINAL AMPS VFD - 2.7 @ 35 HZ PRESSURE INFORMATION FAN IN -0.17 OUT 0.008 RISE 0.181, Remarks: Page 4 of 21 ENGINEERING RECTANGULAR DUCT TRAVERSE REPORT PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM AHU-1 OSA LOCATION/ZONE AIR TEMP. (°F) DUCT S.P. DUCT SIZE 58 X 38 SQ.FT. 15.31 REQUIRED FPM 144 CFM 2200 MEASURED FPM 147.25 CFM 2254 POSITION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 222 231 238 209 2 55 87 73 63 3 4 5 6 7 8 9 10 11 12 13 14 Velocity Subtotals 277 318 311 272 NOTE: Instrumentation used: Airdata Multimeter Velocity readings are automatically corrected for altitude and temperature. ( 1178 / 8 ) = ( 147.25 FPM) ( 15.31 SO.FT. ) = 2254 CFM Remarks: Page 5 of 21 . [PG of ENGINEERING VAV RECAP SHEET PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM: AHU-1 A BOX # ADD # MAX MIN HEAT SIZE MULT REMARKS VAV'S VAV1A.01 1 1560 1320 1320 14" 0.76 VAV1A.02 2 285 145 145 6" 0.72 VAV1 A.03 3 530 160 160 8" 0.69 VAV1A.04 4 385 385 385 6" 0.70 VAV1A.05 5 820 820 820 10" 0.78 VAV1A.06 6 430 130 130 8" 0.72 VAV1A.07 7 790 790 790 10" 0.78 VAV1A.08 8 550 165 165 8" 0.84 VAV1A.09 9 440 440 440 8" 0.73 VAV1 A.10 10 715 600 600 10" 0.87 VAV1A.11 11 150 150 150 6" 0.65 VAV1A.12 12 315 0 0 6" 0.84 TOTAL 6970 5105 5105 Remarks: VAV'S WERE CALIBRATED AND BALANCED WITH GRILLES IN A FULL COOLING MODE Page 6 of 21 ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM /AHLI1 A LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM VAV1 A.01 1 SLOT SLOT 1.0 260 260 267 267 2 SLOT SLOT 1.0 260 260 264 264 3 SLOT SLOT 1.0 260 260 268 268 4 SLOT SLOT 1.0 260 260 260 260 5 SLOT SLOT 1.0 260 260 260 260 6 SLOT SLOT 1.0 260 260 247 247 TOTAL 1560 1566 VAV1 A.02 1 24X24 24X24 1.0 70 70 67 67 2 24X24 24X24 1.0 70 70 69 69 3 24X24 24X24 1.0 70 70 72 72 4 24X24 24X24 t 1.0 75 75 72 72 TOTAL 285 280 P 7of21 ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM /A U- A LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM VAV1 A.03 1 48X24 48X24 1.0 150 150 160 160 2 48X24 48X24 1.0 150 150 148 148 3 48X24 48X24 1.0 230 230 218 218 TOTAL 530 526 VAV1 A.04 1 24X24 24X24 1.0 75 75 79 79 2 24X24 24X24 1.0 105 105 111 111 3 24X24 24X24 1.0 105 105 100 100 4 24X24 24X24 t 1.0 100 100 104 104 TOTAL 385 394 VAV1 A.05 1 24X24 24X24 1.0 80 80 76 76 2 24X24 24X24 1.0 110 110 111 111 3 24X24 24X24 1.0 110 110 106 106 4 24X24 24X24 1.0 110 110 110 110 5 24X24 24X24 1.0 110 110 112 112 8 of 21 ENGINEERING AIR BALANCE DATA PROJECT BANNER FORT COLLINS HEALTH CENTER EXPANSION SYSTEM HU-1 A LOCATION OPENING SIZE REQUIRED FINAL MINIMUM HEATING PLAN ACTUAL AREA VEL CFM VEL CFM VEL CFM VEL CFM VAV1 A.05 6 24X24 24X24 1.0 110 110 117 117 7 24X24 24X24 1.0 110 110 118 118 8 24X24 24X24 1.0 80 80 78 78 TOTAL 1 820 828 VAV1 A.06 1 48X24 48X24 1.0 160 160 165 165 2 48X24 48X24 1.0 160 160 154 154 3 24X24 24X24 1.0 110 110 105 105 TOTAL 430 424 VAV1 A.07 1 24X24 24X24 1.0 105 105 101 101 2 24X24 24X24 1.0 105 105 102 102 3 24X24 24X24 1.0 105 105 100 100 4 24X24 24X24 1.0 105 105 104 104 5 24X24 24X24 1.0 105 105 107 107 6 24X24 24X24 1.0 105 105 107 107 P r 9 of 21