HomeMy WebLinkAbout417 N GRANT AVE - DISCLOSURES - 6/7/2017City of Fort Collins Residential Mechanical Systems Performance Report Updated 3/7/2014
This form is a record of testing targets and results with Pass/Fail outcomes For information on measurement tools City of
and testing techniques see the Residential New Construction Mechanical Systems Testing Guide The guide and Fort Collins
this form may be periodically updated check the Building Services web site for the current version
This form must be completed and signed by an Approved Agency and submitted to Building Services as a requirement for receiving a C O
Color
key
Target
Measured value
Other
to compare voth
Pass
Faili
Caution
or limit
data
target or limit
ADCF = Air Density Correction Factor based on tool
ADCF altitude (5000 ) air temperature through tool
Volumetric flow (CFM 5000) = ADCF x Indicated flow (CFM)
11. House Data
Address 417 N Grant Street Date of Residential
Mechanical Systems
Design Submittal
Builder Torey Lenoch information referenced
HVAC contractor Nardi Air
by testing technicians
As built changes
meth design submi'
Testing date(s) 06 09-17
2. Local Exhaust (Spot Ventilation)
Bath exhaust
Flow x Flow box _ Pdot tube duct traverse
tool — Passive flow hood — Other (note below)
f
r
9
Design
Testing tech (initials) mS
Air temp
through tool (F) 76 ADCF 1 1
Measured Airflow
Minimum Airflow Requirement
Indicated
Volumetric
Exhaust Pickup Location
Airflow
(CFM 5000)
Flow
Flow
Pass
Fail
(CFM
+ Type of Operation
(CFM)
(CFM 5000 )
5000)
upper bath
X 50 Intermittent —20 Continuous
59
0
❑
powder
X 50 Intermittent —20 Continuous
52
0
❑
master bath
X 50 Intermittent — 20 Continuous
59
0
❑
lower bath
X 50 Intermittent —20 Continuous
65
0
❑
50 Intermittent — 20 Continuous
❑
❑
50 Intermittent 20 Continuous
❑
❑
50 Intermittent 20 Continuous
❑
❑
Testing
notes
Kitchen exhaust
N/A
hood does not vent to outside
Testing tech (initials) mS
Oven fuel
—Gas — Electric
Minimum airflow requirement (CFM 5000 ) + operation
_ 100 Intermittent _ 25 Continuous
Measured airflow
1
t Flow
Flow box
— —
Passive flow hood
Pitot tube traverse
Flow grid
Tool
— Interior grille
Exhaust duct
Air temp
through 76 ADCF 1 1
r I tool
— —
location
-
- Powered flow hood _
Other (note below)
(Exterior termination not OK)
tool (F)
I Indicated flow
355
CFM
Volumetric flow
391
CFM 5000 'El Pass ED Fad
I
lTesting
notes
Residential Mechanical Design Submittal V20140307 Page 1
3. Whole -House Ventilation
Systems other than sub structural floor exhaust Testing tech (initials) ipg
Code minimum ventilation airflow
62 CFM 5000 Design ventilation
airflow uu
CFM 5000
X
—Exhaust only
(based on CFA and # of BR
System
Supplyonly
Target ventilation airflow range 62 to
74
CFM 5000
_
type
—Balanced
(code -minimum)
(120/ of design flow)
Measured Airflow
Air Temp
Indicated
Volumetric
Measurement Method
Tool Location
Through
ADCF
Flow
Flow
I
Pass
Fail
Tool (F)
(CFM)
(CFM 5000 )
Total
N/A Passive flow hood
exhaust
_
X Flow box _ Pitot tube traverse
Laundry
76
1 1
62
68
0
❑
airflow
Flow collar _ Other (note below)
Total
_ N/A _ Passive flow hood
❑
❑
supply
_ Flow box _ Pitot tube traverse
airflow
Flow collar Other (note below)
When supply airflow is circulated by air handler fan fan speed for measurement — Heating Cooling Continuous fan
Balanced airflow in balanced systems
Average of measured CFM
Target flow rang)
+/ 15 /0
to
CFM
5000
jj��'l1
I❑ Pass Fail
supply + exhaust flows 5000
(average
LJ
LJ
Testing
notes
Sub structural floor exhaust ® N/A — no sub structural floor exhaust system Testing tech (initials)
Design exhaust airflow (based on Target airflow limits to CFM 5000
approved design)
CFM 5000 (design +/ 15%)
Measured airflow
Flow — Flow box _ Pitot tube traverse Tool Air temp
tool — Passive flow hood — Flow collar through ADCF
location
_ Powered flow hood Other (note below) tool (F)
Indicated flow CFM Volumetric flow CFM 5000 ❑ Pass C Fail
Testing
notes
,4. Heating + Cooling Duct Lea,kage
N/A — No ductwork Testing notes
X No ductwork outside conditioned space (mcl multiple sys)
Duct leakage
data source
—Testing tech (initials)
_ Energy rater (name
company testing date)
House conditioned floor area
(include full basement)meat)
Air temp ADCF
sf through tool (F) �
Maximum Allowed Duct Leakage
Measured Duct Leakage
System #1
System #2
Test Parameter and Conditions
Normalized
(CFM25 5000 / 100 sf)
Absolute
(CFM25 5000)
Indicated
(CFM25)
Volumetric
(CFM25 5000)
Leakage Type
Timing
Air Handler
Pass
Fall
I Pass
Fail
Total leakage
Rough in
Excluded
3
❑
❑
❑
❑
Total leakage
Rough in
Included
4
,
0
❑
❑
❑
Total leakage
Complete
Included
4
❑
❑
❑
❑
Residential Mechanical Design Submittal V20140307 Page 2
� T 'Q� r p3Ai '�iir m '-
5. Heating + Cooling Equipment
For multiple systems attach one page per system
System #a Which parts of house does it serves entire home
Installed equipment (Be clear about which AC components are installed at time of testing) Testing tech (initials) FMS
Furnace or Boiler
AC or Heat Pump Condenser
AC or Heat Pump Coll
Manufacturer
Armstrong
None
ADP
Model#
A96US@V0706125
None
AA09230D17513160167
j I _ Basic fiberglass _ Electrostatic
f Filter Skuttle Type — Basic pleated _Other Thickness 1❑ MERV
k ❑
M brand —High-efficpleated (inches) (optional)
Static pressures Testing tech (initials) mS
F Setup
(Same location
SpeedHeating X Cooling _Cont fan SP4 06 for NSOP
TFSOP)
_ High stage for multi stage equipment \
Blower speed tap hi AP Coil
(SP3 SP4) 29
Humidifier damper X N/
_Opepe n (Heating)
_ Closed (Cooling)
SP3 35
X All registers open
xig
X Zone dampers open � ro
SP1 15 �—
\ } OP Total ESP 56
I (SP3SP2)
OP Filter 06 f'Y r
(SP1 SP2)
\ sl=z 21
Cooling Measured air flow through Indoor toll ❑ N/A — no AC installed Testing tech (initials) FMS
Design cooling airflow Target airflow limits
(high stage) 780 CFM 5000 (design +/ 15%) 663 to $g7 CFM 5000
i
Measured airflow
Flow grid _ 14 Air temp Flow Resistance
plate size _ 20 1 through
ADCF� NSOP❑ TFSOP❑ Correction Factor
tool F
Measured airflow no CFM Indicated �CFM Volumetric airflow CFM Pass
j adjustment/correction Measured AF x FRCFFRCF Indicated AF x ADCF 5000 Fad
i
No air condtloner in home
Heating Gas manifold pressure (high stage)
HManifold pressure 3 5 IWC Target manifold P 3 G to 3 7
OEM spec @ 5000 limits (spec +/ 5%)
Heating Temperature rise
Temp
OEM temperature rise limits 25 to 55 Supply Return F
(high stage)
IMeasured temps (F) air 109 — air 76 — rise 33
Testing tech (initials) mS
IWC Measured 35 IWC M Pass
pressure CFail
Testing tech (initials) mS
[Pass I(J Fail Caution within 10F
LaJ of top of range
Residential Mechanical Design Submittal V20140307 Page 3
16. Refrigerant Charge
Testing tech (initials)
Testing approach and targets
F' t❑ N/A No complete AC system 8 N/A House completed November April (installing contractor responsible for testing in wane weather)
I
❑ TXV Subcooling + SH check ❑ Non TXV Superheat i❑ OEM specific Approach ❑ Other OEM specific (documentation required)
Temperatures Condenser Non TXV Return Target Target Target
(F) entering air temp air wet bulb temp superheat subcooling approach
Subcooling
Dlschar a
pressure
Condenser
saturation T F
liquid Actual
line F subcooling
F
El TXV Pass Actual SC within +/
3 F of target SC 2 F min
(PSI)
(5000 chart)❑
temp❑ (CondT liq line T)
—[,TXV Fail
Superheat
Suction
pre
Evaporator
saturation T❑F
Suction Actual
nP❑F Superheat
❑F
❑Non TXV Pass Actual SH
+/ 5 F of target SH
(sure❑
PSI)
(s000 chart)
tem (SucllineT evapT)
�within
❑ Non TXV Fail
TXV checks ❑ Pass
Field installed TXV installed in accordance with OEM instructions
ECaution
Actual SH outside mfgr range
Approach
Liquid lineF1F
Actual approach�F ❑Approach Pass Actual approach within +/ 1 F of target approach
line T Condenser EAT)
temp
(Lig
OlApproach Fail
7. Room Air Flow
Register air flows Testing tech (initials) FMS
All registers are cut through finish materials and moving air �Q Pass ❑❑ Fail
(Remainder of register air flow section under development not yet being enforced)
Pressure balance
Testing tech (initials) Fms
Room
(match names on plans include
basement if there is a door)
Room to -Core
Pressure Drop
Target Range (Pa)
Measured
Pressure
Drop (Pa)
Pass
Fail
low north bed
3 to +3
+0 3
0
❑
low south bed
3 to +3
02
0
❑
master
3 to +3
+0 1
0
❑
S bed
3 to +3
02
0
❑
N bed
3 to +3
03
0
❑
3 to +3
❑
❑
3to+3
❑
❑
3 to +3
❑
❑
3 to +3
❑
❑
3 to +3
❑
❑
Residential Mechanical Design Submittal V20140307 Page 4
8. Combustion Safety
El (Appliance
safety testing N/A — no natural -draft combustion appliances Testing tech (initials) fT1S
(Appliance Types table must be completed for every home)
Appliance types
Appliance
Combustion Type
N/A
Draft hood
Natural -draft
Induced -draft
Natural -draft
Power
vent
Direct
vent
Powered sealed
combustion
Electric
Furnace #1
❑
❑
❑
❑
❑
0
❑
Furnace #2
❑
❑
❑
❑
❑
❑
❑
Boiler #1
❑
❑
❑
❑
❑
❑
❑
Boiler #2
❑
❑
❑
❑
❑
❑
❑
Water heater#1
❑
❑
❑
❑
❑
0
❑
Water heater #2
❑
❑
❑
❑
❑
❑
❑
Fireplace #1
0
❑
❑
❑
❑
❑
❑
Fireplace #2
❑
❑
❑
❑
❑
❑
❑
Other
❑
❑
❑
❑
❑
❑
❑
Worst -case depressurization performance
# of bath fans on
Vented range hood on
Clothes dryer on
Air handler on
fans on
i I i
Outdoor temperature = F
CAZ pressure
doors are closed
setup notes
Tested appliances
Appliance
Location
BPI depressurization limit (Pa wrt outside)
Measured net CAZ depressurization (Pa wrt outside)
OK (less negative) I Caution (more negative)
Spillage
BPI maximum limit (seconds'
f Measured spillage duration (seconds
1 Pass = duration not exceeding limit
(Draft pressure
BPI limit (Pa wrt CAZ
Measured (Pa wrt CAZ
Pass = pressure more negative than limit
�CO concentration In undiluted flue gas
BPI maximum limit (ppm
Measured CO (ppm
Pass = CO level not exceeding limit
Caution = CO level 25 to 100 ppm
❑
OK
❑
Caution
❑
OK
1 ❑
1 Caution
❑
OK
❑
Caution
60
60
60
0
Pass ❑ Fail
❑
Pass I ❑ Fail
I ❑
Pass ❑ Fail
❑ Pass ❑ Fail ❑ Pass I ❑ Fad ❑ Pass ❑ Fail
100
100
100
0
Pass
❑
Fail
0
jPass
I ❑
Fail
0
Pass
I ❑
Fail
❑
Caution
❑
Caution
❑
ICaution
Residential Mechanical Design Submittal V20140307 Page 5
19. System -Controls
Testing tech (initials) RIS
System
Controls Operating
Per Design Intent
Local exhaust (all fans)
❑
N/A
0
Pass
❑
Fail
Whole house ventilation
❑
N/A
0
Pass
❑
Fail
Sub structural floor exhaust
0
N/A
❑
Pass
❑
Fail
Heating (all systems)
❑
N/A
0
Pass
❑
Fail
Cooling (all systems)
❑
N/A
0
Pass
❑
Fad
Signatures
Testing Notes
Technician #1 performing inspection and testing documented on this report (Approved Agency)
I certify that the tests referenced above in sections bearing my initials were performed in accordance with protocols specified by the
City of Fort Collins Building Services Department and that the reported results are accurate to the best of my knowledge
Name (print)
Title
Company
Signature and Date
Matt Schubert
Energy Rater
GS Services
o see rna
MattON CN Matl SN Derl mall
i �rcCr.�Ous 0 sank
rt�IIC U5O55 nken
Schub&ton mvoe ozuvn
Technician #2 performing inspection and testing documented on this report (Approved Agency)
]I certify that the tests referenced above in sections bearing my initials were performed in accordance with protocols specified by the
City of Fort Collins Building Services Department and that the reported results are accurate to the best of my knowledge
Name (print)
Title
Company
Signature and Date
HVAC Contractor (City of Fort Collins license holder)
I certify that I have reviewed this report and that the lest results are an accurate representation of the performance of the installed mechanical
systems
t
Name (print)
Title
Company
Signature and Date
Residential Mechanical Design Submittal V20140307 Page 6