HomeMy WebLinkAbout417 N GRANT AVE - DISCLOSURES - 5/26/2017BUILDING LEAKAGE TEST 6](MS19q
GIG.4I t'GS Services LTD\s �itsr 2000 S College Ave #308
Fort Collins CO 80525
Email buildingperformance@gsservices corn Website gsservlces corn
Date of Test 5/26/2017
Customer Torey Lenoch
Test Results
1 Airflow at 50 Pascals
(50Pa=02wc)
2 Leakage Area
3 Building Leakage Curve
4 Test Settings
Test File Torey Lenoch - 417 N Grant Ave BDma
Technician Nick Hiseler
Project Number
Building Address 417 N Grant Ave
Fort Collins CO
963 CFM50 ( +/ 2 7 %)
2 12ACH50
53 0 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 54 8 (+/- 19 7 %)
Exponent (n) = 0 733 ( +/ 0 055 )
Correlation Coefficient = 0 99724
Test Standard RESNET Multi -Point Test
Test Mode Depressurization
5 Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1 Estimated Average Annual Infiltration Rate 44 2 CFM
0 10ACH
2 Estimated Design Infiltration Rate Winter 64 5 CFM Summer 47 4 CFM
0 14 ACH 0 10 ACH
Cost Estimates
1 Estimated Cost of Air Leakage for Heating
2 Estimated Cost of Air Leakage for Cooling
Digitally signed by
Paul
Paul Higman
/DN/CN = Paul
H igma n�Higman C = US
Z. D,j{e 2017 05 26 15
t 5t1 47 0600
or
r SAS�s BUILDING LEAKAGE TEST Page 2 of 4
Date of Test 5/26/2017 Test File Torey Lenoch 417 N Grant Ave - BDma
Building Information
Volume
27240
Surface Area
Floor Area
3010
Height
9
# of Bedrooms
3
# of Occupants
Year of Construction
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel
Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Location Climate Information
Ventilation Weather Factor
087
Energy Climate Factor
1700
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7 3 mph
Design Summer Wind Speed
9 4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
19247
Default
Micromanometer
Energy Conservatory
DG700
GS
1 S BUILDING LEAKAGE TEST Page 3 of 4
Date of Test 5/26/2017 Test File Torey Lenoch 417 N Grant Ave BDma
Depressurization Test
Environmental Data
Indoor Temperature (A°F)
Outdoor Temperature (A°F)
Altitude (ft)
670
1 650
1 50000
Data Points - Data Entered Manually
Nominal Baseline Adjusted Fan Nominal Adjusted
Building Pressure Building Pressure Pressure Flow Flow Fan
(Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration
-1 3
n/a
n/a
-61 3
599
327
550
536
281
490
476
2244
41 8
404
1868
371
358
1565
-30 9
295
1198
256
-24 3
846
204
-19 0
553
14
n/a
n/a
Time Averaging Period 10
None
1041
1080
-1 8
Ring A
967
1003
1 1
Ring A
887
920
1 0
Ring B
810
840
1 9
Ring B
742
770
22
Ring B
650
674
30
Ring B
547
567
01
Ring B
443
460
-3 2
Ring B
Deviations from Standard RESNET Multi Point Test - Test Parameters
GSSertes BUILDING LEAKAGE TEST Page 4 of 4
Date of Test 5/26/2017 Test File Torey Lenoch 417 N Grant Ave - BDma
Comments
Detached Garage