Loading...
HomeMy WebLinkAbout825 E LAUREL ST - CORRESPONDENCE - 5/1/2017City Of Planning, Development, and Transportation Fort Collins Community Development & Neighborhood Services 281 N College Ave PO Box 580 Fort Collins CO 80522 970 416 2740 970 224 6134 fax fcgov coaVnbs Rental Housing Inspection Results 5/1/2017 Ralph Kiel 2331 Fleming Dr Loveland, Co 80538 RE 825 d 82 E Laurel St Fort Collins, Co 80524 Parce umber 97131-17-028 lufmlll - Our records indicate you are the owner of the above referenced address This letter is to inform you that an inspection of this property was performed on 4/17/2017 the purpose of which was to verify compliance with the Structure and Premises Condition Code of the City of Fort Collins, (Rental Housing Code, 2006 International Property Maintenance Code, (IPMC)) as adopted by the City The inspection determined items that are not in compliance with the Rental Housing Code that need to be corrected • Have roof inspected due to deterioration • Replace mussing siding, fix fascia and gutters, replace all broken or nonfunctioning windows • Install guards and handrail protection on all stairways Fix stairs, secure posts, address drainage issues • Install smoke and carbon monoxide detectors through dwelling units • Need to permit 2 furnaces and water heater, permit basement will need to contact State for removing asbestos and have clean air report after construction to obtain Letter of Completion • Reinstate perrrut on back storage building cover and install electrical cover and reside and paint • Have electrician go through both units and bring up to code check all electrical that tenant disconnected The above mentioned items are considered General Maintenance items and must be repaired within (30) days of the date of this notice Unit 827 in its current condition should not be occupied Furnace and water heater will be checked by a licensed contractor to make sure they are in good working order The furnace company will also verify there is enough combustion air for both appliances We will need verification in written form from the contractors All electrical work will need to be done by a licensed electrician verified by letter 825 uid 827 L I autel h„ c- You are required to schedule an inspection when the work is completed to verify that all the work was performed Failure to comply with this request may result in a citation being issued Sincerely James Warren Building Inspector City of Fort Collins Community Development & Neighborhood Services (970)4162359 lwarren@fc og v com