HomeMy WebLinkAbout619 CHERRY ST - DISCLOSURES - 2/20/2017,• �-' n e r gy L o g i c BUILDING LEAKAGE TEST '' analysis. Insight. answesss'. l cooyy�2 Date of Test: 2/20/2017 Test File: 619 Cherry St Frameworks Timber REM 14.6.4 Multi Point Tectite Customer: Frameworks Timber Technician: Neal Girard - EnergyLogic, Inc. Project Number: 45430 Building Address: 619 Cherry St Ft. Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 483 CFM50 (+/- 1.0 %) (50 Pa = 0.2 w.c.) 1.06 ACH50 2. Leakage Area: 26.5 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 21.4 (+/ 15.3 %) Exponent (n) = 0.797 ( +/- 0.040 ) Correlation Coefficient = 0.99871 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 30.1 CFM 0.07 ACH 5.0 CFM per person 2. Estimated Design Infiltration Rate: Winter: 52.9 CFM Summer: 33.2 CFM 0.12 ACH 0.07 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 73.9 CFM Base Rate: 73.9 CFM -QijergyLogic BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/20/2017 Test File: 619 Cherry St Frameworks Timber REM 14.6.4 Multi Point Tectite Building Information Location Climate Information Volume 27387 Surface Area 5794 Floor Area 2888 Height 25 # of Bedrooms 5 # of Occupants 6 Year of Construction 2017 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Micromanometer Energy Conservatory DG700 6108-5 1 1/17/2014 VnergyLogic BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/20/2017 Test File: 619 Cherry St Frameworks Timber REM 14.6.4 Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 62.0 62.0 5000.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -3.3 n/a n/a -62.1 -57.9 75.7 -58.6 -54.3 68.6 -55.7 -51.4 62.9 -51.9 -47.6 56.0 -47.5 -43.2 48.4 -44.0 -39.7 39.9 -38.7 -34.4 32.8 -34.8 -30.5 27.5 -5.3 n/a n/a Time Averaging Period: 10 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 518 541 -0.1 Ring B 493 516 0.1 Ring B 472 494 0.2 Ring B 446 466 0:5 Ring B 415 434 0.9 Ring B 377 394 -2.0 Ring B 342 358 -0.2 Ring B 314 328 0.8 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters iDnergyLogic BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2/20/2017 Test File: 619 Cherry St Frameworks Timber REM 14.6.4 Multi Point Tectite Comments Connection to: Garage: NA Mechanicals: NA