Loading...
HomeMy WebLinkAbout6215 SAKER CT - DISCLOSURES - 7/8/2016 (2)czza =0 BURGESS ENERGY SERVICES A DIVISION OF BURGESS CONSTRUCTION CCINSULTANTS, INC. AIR LEAKAGE REPORT Date: July 08, 2016 Rating No.: 03172016CF Building Name: Montana Rating Org.: Burgess Inc -BCCI Owner's Name: Toll Brothers Phone No.: 303-300-4527 Property: 6215 Sake Court Rater's Name: Barrett Hendricks Address: Fort Collins, CO 80528 Rater's No.: 6761425 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 6215 Saker Court.blg Rating Date: 7/8/16 Whole House Infiltration Duct Leakage Ventilation Blower door test Heating Cooling Natural ACH: 0.10 0.08 I ACH @ 50 Pascals: 2.10 2.10 CFM @ 25 Pascals: 924 924 CFM @ 50 Pascals: 1450 1450 Eff. Leakage Area: [sq.in] 79.6 79.6 j Specific Leakage Area: 0.000141 0.00014 ELA/100 sf shell: [sq.in] 0.68 0.68 Leakage to Outside Units Ducts down , CFM @ 25 Pascals: CFM25/CFMfan: 0.0000 CFM25 /CFA: 0.0000 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 0 Eff. Leakage Area: [sq.in] 0.00 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0342 Mechanical: ! Exhaust Only ASHRAE Sensible Recovery Eff. (%): 0.0 62.2-2010 Total Recovery Eff. (%): 0.0 Rate (cfm): 82 .71 Hours/Day: 24.0 24 j Fan Watts: 11.3 Cooling Ventilation: Natural Ventilation Regarding ASHRAE 62.2 Ventilation Compliance The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole -building' requirement under thatversion of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v14.6.3 This information does not constitute any warranty of energy cost or savings. @ 1985-2016 Noresco, Boulder, Colorado. c5trr� BURGESS ENERGY SERVICES A DIVISION OF BURGESS CONGTRUCTIDN CDNSDLTANTS, INC. COMPONENT LOAD SUMMARY Date: July 08, 2016 Rating No.: 03172016CF Building Name: Montana Rating Org.: Burgess Inc- BCCI Owner's Name: Toll Brothers Phone No.: 303-300-4527 Property: 6215 Saker Court Rater's Name: Barrett Hendricks Address: Fort Collins. CO 80528 Rater's No.: 6761425 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 6215 Saker Court.blg Rating Date: 7/8/16 Montana HEATING SEASON (MMBtu/yr) Ceilings/Roofs 12.2 Rim/Band Joists 2.4 Above Grade Walls 30.7 Foundation Walls 10.8 Doors 1.0 Windows/Skylights 11.6 Floors 0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors 11.0 Infiltration 3.9 Mechanical Ventilation 13.3 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -18.7 Total 78.2 REM/Rate - Residential Energy Analysis and Rating Software v14.6.3 This information does not constitute any warranty of energy cost or savings. ©1985-2016 Noresco, Boulder, Colorado. COMPONENT LOAD SUMMARY Montana Page 2 Montana COOLING SEASON (MMBtu/yr) Ceilings/Roofs 0.4 Rim/Band Joists -0.2 Above Grade Walls -0.2 Foundation Walls -1.1 Doors -0.1 Windows/Skylights 7.3 Floors 0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors -3.9 Infiltration -0.2 Mechanical Ventilation -1.0 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains 12.8 Whole House Ventilation -4.3 Total 9.6 REM/Rate - Residential Energy Analysis and Rating Software v14.6.3 This information does not constitute any warranty of energy cost or savings. ©1985-2016 Noresco, Boulder, Colorado. rr� BURGESS ENERGY SERVICES A DIVISION OF BURGESS CONSTRUCTION CONSULTANTS, INC. 2012 IECC ANNUAL ENERGY COST COMPLIANCE Date: July 08, 2016 Rating No.: 03172016CF Building Name: Montana Rating Org.: Burgess Inc - BCCI Owner's Name: Toll Brothers Phone No.: 303-300-4527 Property: 6215 Saker Court Rater's Name: Barrett Hendricks Address: Fort Collins, CO 80528 Rater's No.: 6761425 Builder's Name: Toll Brothers Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 6215 Saker Court.big Rating Date: 7/8/16 Annual Energy Cost ($) 2012 IECC As Designed Heating: 682 635 Cooling: 195 139 Water Heating: 121 121 SubTotal - Used to Determine Compliance: 998 895 Lights & Appliances: 986 968 Photovoltaics: -0 -0 Service Charge: 240 240 Total: 2224 2103 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.300 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 10.3%. Signature: Name: Barrett Hendricks Organization: Burgess Inc - BCCI Date: July 08, 2016 Design energy cost is based on the following systems: Heating: Fuel -fired air distribution, 60.0 kBtuh, 92.0 AFUE. Cooling:Air conditioner, 36.0 kBtuh, 13.0 SEER. Water Heating: Conventional, Gas, 0.62 EF. REM/Rate - Residential Energy Analysis and Rating Software v14.6.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Montana 2012 IECC ANNUAL ENERGY COST COMPLIANCE Window -to -Floor Area Ratio:0.12 Blower door test: Htg:1450 Clg: 1450 CFM50 Page 2 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect currentfederal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.6.3 This information does not constitute any warranty of energy cost or savings. 01985-2016 Noresco, Boulder, Colorado. 2012 IECC Certificate 6215 Saker Court, Fort Collins, CO 80528 .--.......... .......-- . ._. Building Envelope Insulation Ceiling: R-38.0 Above Grade Walls: R-21.0 Foundation Walls: R-19.0 Exposed Floor: NA Slab: R-0.0 Edge, R-0.0 Under Infiltration: Htg: 1450 Clg: 1450 CFM50 Duct: NA Total Duct Leakage: 140.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window: 0.300 0.320 Mechanical Equipment HEAT: Fuel -fired air distribution, Natural gas, 92.0 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Conventional, Natural gas, 0.62 EF, 48.0 Gal. Builder or Design Professional Signature RE1WRate - Residential Energy Analysis and Rating Software 04.6.3 a /A BURGESS . oN�c:ow ENEi76V SELiVIGES 22" Uniform Energy Rating System Ra&v Montana 6215 Saker Court Fort Collins, CO 80528 5 Stars Plus Confirmed 1 Star 1 Star Plus 2 Stars 12 Stars Plus 3 Stars 3 Stars Plus 500-401 400 301 300-251 250-201 200-151 150-101 Registry ID: 068681314 ,.: Rating Number: 03172016CF Certified Energy Rater: Barrett Hendricks Rating Date: 7/8/16 Rating Ordered For: Toll Brothers Energy Efficient 4 Stars Plus ars Ot 91 70tor Less .........................:........_........ ......... ... _.......... . Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 80.0 $517 27% Cooling 2.0 $57 3% Hot Water 20.2 $121 6% Lights/Appliances 33.0 $968 51% Photovoltaics -0.0 $-0 -0% HERS Index: 57 Efficient Home Comparison: 43% Better .... ........---...................... ... . - .._....._..._.. ....__.._.__._..._....._...._...__..._.._....._..........._...._• Service Charges $240 g 13% ................_.__...... .... ..... ............_........... General Information ........... ........ ... ..._._..........._._.._.._........... -...._........-...... .......... ... Total 135.3 $1904 100% ........ _........ _.._....................... ...-...... ............... ........ _........ _..... _...... _......... ..... ........ .._.............._..._.._........__......_.._........._.... ......... _.._....... ............ Conditioned Area: 4091 sq. ft. HouseType: Single-family detached ...........................:.......... ........__.....—...._..._..- _ .........._....._......_.__.__..._,_........_........._ : ......, Conditioned Volume: 41390 cubic ft. Foundation: More than one type ---- -- — - - - -- - - ---- - This home meets or exceeds the minimum - Bedrooms: 3 .__._...-----..........__.._...---..__..._..._......................__....---._........._..._........._........._,__..___.. _......_---•-----......-- --...r _._ - ---.._.._.,_._.._..._ .............. .._,..... ....... ..-- - criteria for all of the following: Mechanical Systems Features __....__.._....... _.......---................._.... ........._ :_.........._._.....:..._.:........ ....... .._...— ..... _...... -----...._,_..... --- ._....._..........._._.....- - .._....__.............. --- -....._..._:_.•._....-..........., Conservation 2006 International Energy Code Heating: Fuel -fired air distribution, Natural gas, 92.OAFUE. 2009 International Energy Conservation Code Cooling: Air conditioner, Electric, 13.0 SEER. 2012 International Energy Conservation Code Water Heating: Conventional, Natural gas, 0.62 EF, 48.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 82 cfm, 11.3 watts. Programmable Thermostat: Heating: Yes Cooling: Yes _._.._..............._.-...._.... ....... ........ .. _...._....... _....._......... __......._..__...._.......__......_..............._._. _._....... _....._ ...._...-...........__........._...__.._........._...._... Building Shell Features _ _.........._.__..P .-.... ........................... _...._.._......._._..._-.._-_......._ ...._. _.... __..... ...... ... ....._......... _. :... _...:-..._............... ... ........ _............ ..... .......... __.._......_........._.__....._........_.-._.... Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: NA Vaulted Ceiling: NA Window Type: U-Value: 0.300, SHGC:0.320 Above Grade Walls: R-21.0 Infiltration Rate: Htg: 1450 Clg: 1450 CFM50 Foundation Walls: R-19.0 Method: Blower door test ..._......._....................._.............................._._...... ..-_....._..._._............ . -.........._......._................. _._..._.._.._..._ .........._.._......_...._...._...._._.._......_......-. ..._.._......-._................_...__, _....--- ..... .......... _........ ...................... Lights and Appliance Features ... ....... ._.......... .. _............. ........_............. _....._.........._......-._..._......_........_..........-. _...; Percent Interior Lighting: 50.00 Range/Oven Fuel: Electric MORTGgGe BurgessConstructionConsultantsl o�Py Percent Garage Lighting: 50.00 Clothes Dryer Fuel: Electric 101 W Renner Rd, Suite 4002P Refrigerator (kWh/yr): 475.00 Clothes Dryer EF: 2.67 Richardson, Texas 75082u-` Dishwasher Energy Factor: 0.68 Ceiling Fan (cfm/Watt): 0.00 214-888-7260 ldo. ssa 1aa �¢ The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 214-888-7261 sy �v�y• REM/Rate - Residential Energy Analysis and Rating Software v14.6.3 CCReO1� TATlON r��- i�^`'�`` -w�. This information does not constitute any warranty of energy cost or savings. 01985-2016 Noresco, Boulder, Colorado. Certified Energy Rater