HomeMy WebLinkAbout257 OSIANDER ST - DISCLOSURES - 6/17/2016BUILDING LEAKAGE TEST 4 1EFFICIENCY ',(M A T T E R 5 Date of Test: 6/17/2016 Customer: Daron Hays 257 Osiander St Fort Collins, CO 80524 Phone:9704200500 Email: daronhays@gmaii.com Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: Test File: Airleakagetest2570siander Technician: Mike Rodriguez Project Number: 257 Building Address: 257 Osiander St Fort Collins, CO 80524 413 CFM50 1.27 ACH50 0.2376 CFM50/ft2 floor area 0.2376 CFM50/ft2 surface area 42.7 in2 Canadian EgLA @ 10 Pa 22.7 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 32.5 Exponent (n) = 0.650 (Assumed) Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 19.3 CFM 0.06 ACH 6.4 CFM per person (using bedrooms + 1) Winter: 27.7 CFM Summer: 20.3 CFM 0.09 ACH 0.06 ACH No Text No Text No Text