Loading...
HomeMy WebLinkAbout3002 ZEPHYR RD - DISCLOSURES - 6/3/2016BUILDING LEAKAGE TEST Date of Test: 06/03/2016 Test File: Toll Brothers Blower Door Customer: Toll Brothers 10 Inverness E Dr Ste 125 Englewood, CO 80112 Phone 303-708-0730 Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Areas 3. Minneapolis Leakage Ratio 4. Building Leakage Curve: 5. Test Settings: Technician: Jay Bundy Building Address: 3002 Zephyr Road Ft Collins, Colorado 80528 1026 CFM (+/- 0.4 %) 1.70 ACH 0.27 CFM per ft2 floor area 80.0 in2 (+/- 4.0 %) Canadian EgLA @ 10 Pa 36.3 in2 (+/- 6.1 %) LBL ELA @ 4 Pa 0.22 CFM50 per ft2 surface area Flow Coefficient (C) = 40.8 ( +/- 9.3 %) Exponent (n) = 0.824 ( +/- 0.023 ) Correlation Coefficient = 0.99880 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 35.1 CFM 0.06 ACH 2. Estimated Design Infiltration Rate: Winter: 45.9 CFM 0.08 ACH Summer: 27.3 CFM 0.05 ACH 3. Recommended Whole Building Mechanical 60.3 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: No Text No Text