HomeMy WebLinkAbout612 E PITKIN ST - SPECIAL INSPECTIONS - 5/23/2016TD ST UG-TUR7,L ENGINElf- R NG INC May 23 2016 Lamar Valley Craftsman �� O 2620 Brush Creek Drive Fort Collins, CO 80528 Observation Report Project: McGaughran Residence Location: 612 E. Pitkin St., Fort Collins Colorado TDSE Project No.: 15-053 Observation Date: February 25th and May 19th, 2016 Plans/Details: Plans by TD Structural Engineering Inc. dated 10/13/15 and revised 10/29/15 Items Observed: wood framing Notes: The following items required attention on 2126/16 inspection and have be substantially completed per our 6119/16 inspection: 1. Hurricane ' ties at each truss bearing location on interior bearing wall between flex room and laundry room. 2. Strapping 'across all severed top plates. 3. inverted hangers were not installed at roof overhangs per detail 7/S3.2. 4. Change in window configuration in flex room requiring a (3) 7'/4" LVL header. 5. Squash blocking beneath all posts and trimmers. 6. LVL ledger connection at interior wall bearing wall between living room and hallway was installed per plan with corrections completed since 2/25/16 inspection. The following items still need correcting: 7. Trimmers, supporting garage door header with inadequate bearing need to be attached to king studs with minimum ten 6" lag screws staggered, typical each side. Sincerely, 5171-41 -J'" Y/jr, 4-- Jordan M. Halvorson, E.I.T. Associate Engineer TD Structural Engineering Inc. Wendy Thomas Di President TD Structural Engi Ao0 RE�,s�:-. Oc S. ZoO 38181 o r` .`, . ......... TD 5tructural Engineering, Inc. 12309 Oxford Ct., Fort Collins, CO 50525 1970.372. 1 140 1 www.tcl5tructural.com