Loading...
HomeMy WebLinkAbout2014 YEARLING DR - DISCLOSURES - 5/6/2016BUILDING LEAKAGE TEST .nergyL6g1c .an my sis.::.insight.. answers. wvom.n�g1091C.Com Date of Test: 5/6/2016 Test File: 2014 Yearling Dr Multi Point Tectite Customer: DR Horton Technician: Brad Smith - EnergyLogic Project Number: 40607 Building Address: 2014 Yearling Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1833 CFM50 (+/- 0.5 %) (50 Pa = 0.2 w.c.) 2.45 ACH50 2. Leakage Area: 100.8 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 112.1 (+/- 8.0 %) Exponent (n) = 0.714 (+/- 0.021 ) Correlation Coefficient = 0.99957 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 120.7 CFM ' H U. 1 6 AC 24.1 CFM per person 2. Estimated Design Infiltration Rate: Winter: 201.0 CFM Summer: 126.1 CFM 0.27 ACH 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation ,Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 69.6 CFM Base Rate: 83.7 CFM Infiltration Credit: <14.1 CFM> 1 QnergyLog'ic , �r1Y�'.ILgao��c.�o�, BUILDING LEAKAGE TEST Page 2 of 4 I Date of Test: 5/6/2016 Test File: 2014 Yearling Dr Multi Point Tectite �, Buildin Information Location Climate Information � g ----- - --- -------.._._. Volume 44801 �Ventilation Weather Factor ; 0.87 � SurFace Area 9303 - Energy Climate Factor 17.00 ' --- -....- ----- ------ ---- . � Floor Area 4623 � Heating Degree Days 6128 Height 30 i Cooling Degree Days 297 --.._.......- �-- --- ......--- ------- #of Bedrooms 4 i Design Winter Wind Speed 7.3 mph _ #of Occupants 5 �Design Summer Wind Speed 9.4 mph - - ---- -- - -----...- ------- ;Year of Construction 2016 i Design Winter Temp Diff _73 deg F � -------- ---- �Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information � --------- . - -- --- Heating Fuel � Gas Heating Fuel Cost ; , Heating Efficiency% 'Cooling Fuel Cost ' Cooling SEER Equipment Information Type Manufacturer i Model Serial Number Custom Calibration Date ..---- --- ----- -------�---• Fan Energy Conservatory Model 3 (110V) i Default � Micromanometer Energy Conservatory DG700 13013-7 � 4/16/2015 , Qner.gyLo.gic •�:'r;�r.:glo^yi�.co:fi BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/6/2016 Test File: 2014 Yearling Dr Multi Point Tectite Depre�surization Test: Environmental Data ---�- - ----- --- - ---- - .. Ir�door Temperature (°F) Outdoor Temperature (°F) Altitude (ft) ' ----- --- --- --- 74.0 72.0 5003.0 � Data P��ints Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) ' (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.�1 n/a n/a -61.1 -59.8 124.9 2001 2085 0.1 Ring A -56.8 -55.6 112.3 1900 1979 0.1 Ring A -53:2 -52.0 100.3 1798 1873 -0.5 Ring A -48.9 -47.7 89.3 1699 1770 -0.1 Ring A -45.1 -43.9 80.4 1614 1681 0.7 Ring A -41.2 -40.0 68.5 1493 1555 -0.4 Ring A -36.9 -35.6 59.1 1390 1448 0.6 Ring A -32.9 -31.7 48.7 1265 1317 -0.4 Ring A -1.4 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test-Test Parameters f�one QriergyLogic �.,�;v.rzg��oic.co� BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/6/2016 Test File: 2014 Yearling Dr Multi Point Tectite Comments Connection to: Garage: 45.9 Mechanicals: -50 Pa