HomeMy WebLinkAbout2014 KERRY HILL DR - DISCLOSURES - 3/11/2016 (9)Osn.,ergyL. ogic <1naly51s. In31gh1. answers.. wvvwaglogic.com BUILDING LEAKAGE TEST Date of Test: 3/11/2016 Test File: 2014 Kerry Hill Dr Multi Point Tectite Customer: DR Horton Technician: Brad Smith - EnergyLogic Project Number: 39748 Building Address: 2014 Kerry Hill Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 2033 CFM50 (+/- 0.3 %) (50 Pa = 0.2. w.c.) 2.11 ACH50 2. Leakage Area: 111.8 in2 LBL ELA @ 4 Pa 3. Building, Leakage Curve: Flow Coefficient (C) = 144.5 (+/- 5.4 %) Exponent (n) = 0.676 ( +/- 0.014 ) Correlation Coefficient = 0.99978 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 118.6 CFM 0.12 ACH 19.8 CFM per person 2. Estimated Design Infiltration Rate: Winter: 223.0 CFM Summer: 139.9 CFM 0.23 ACH 0.14 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 96.4 CFM Base Rate: 100.3 CFM Infiltration Credit: <4.0 CFM> QnergyLogic :ogic.com BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/11/2016 Test File: 2014 Kerry Hill Dr Multi Point Tectite Building Information Volume _ 57918 Surface Area I 10220 Floor Area 5533 _I Height _ 20 # of Bedrooms # of Occupants _ _ _ 5 6 Year of Construction 2016 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor _ 0.87 Energy Climate Factor _ 17.00 Heating Degree Days Cooling Degree Days _ 6128 i � 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number ; Custom Calibration Date Fan Energy Conservatory I Model 3 (110V) Default Micromanometer Energy Conservatory DG700 13013-7 4/16/2015 1 QnergyLogic 7mug:ogic.com BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/11/2016 Test File: 2014 Kerry Hill Dr Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 64.0 72.0 j 5003.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.5 n/a n/a -60.6 -59.8 152.3 2204 2300 0.2 Ring A -56.3 -55.5 137.3 2096 2187 0.2 Ring A -52.0 -51.3 123.0 1986 2073 0.2 Ring A -48.5 -47.8 110.2 1882 1965 -0.3 Ring A -44.9 -44.2 98.5 1783 1860 -0.6 Ring A -40.2 -39.5 85.3 1662 1734 0.1 Ring A -36.3 -35.6 73.6 1546 1613 -0.1 Ring A -32.7 -32.0 64.1 1446 1509 0.3 Ring A -0.9 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None QnergyLo:gic yarr:ug;ogic.com BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/11/2016 Test File: 2014 Kerry Hill Dr Multi Point Tectite Comments Connection to: Garage: -46.8 Mechanicals: -50 Pa