Loading...
HomeMy WebLinkAbout2662 Geranium Ln - Disclosures/Blower Door Test - 01/15/2016BUILDING LEAKAGE TEST Date of Test: 1 /15/2016 Customer: CC Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Test File: 2662 Geranium lane Technician: Michael Broussard Project Number: Building Address: 2662 Geranium Lane Fort Collins, Colorado 1942 CFM50 (+/- 43.3 %) 2.83 ACH50 106.8 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 126.0 ( +/- 890.9 %) Exponent (n) = 0.699 ( +/- 2.266 ) Correlation Coefficient = 0.96898 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Reduced Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 1/15/2016 Test File: 2662 Geranium lane Building Information Location Climate Information Volume 41192 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 1/15/2016 Test File: 2662 Geranium lane Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 68.0 28.0 6900.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1 0.4 n/a n/a -69.2 -56.5 162.7 2276 2210 4.5 Ring A -72.3 -59.7 148.7 2178 2114 -3.8 Ring A -51.6 -38.9 86.0 1668 1619 -0.6 Ring A -15.0 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters - Fewer than 8 data points were taken. - * correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi -Point Test Standard. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 1/15/2016 Test File: 2662 Geranium lane Comments -46.5 to garage-Passed , �