Loading...
HomeMy WebLinkAbout894 WATERCOURSE WAY - SPECIAL INSPECTIONS - 2/3/2021STRUCTURAL OBSERVATION REPORT Job No. FRDV7-19512-C6 Date signed: February This is a verified password secured s2ic FR Development 13 zoo J' 125 S. Howes St. Fort Collins, Colorado 80521 ATTN: Chris Wilson Re: Revision of plans for the residence at`894 Watercourse Way, Fort Collins Dear Mr. Wilson: On January 28, 2021, I reviewed the plans designed by our firm signed 10/l/20 regarding a modification to the beam composed of (2) 11-7/8" 2600 Fb laminated veneer lumber (LVL) members in the north framing of the stairs. During construction, the LVL beam was interrupted by a steel beam and placed on the outside of the stair wall. This LVL beam supports a truss and needs supported. Do this by installing (2) 2x10 blocking on top of the basement wall top plate in the stair framing. Fastening the LVL to the 2x10 blocking with (6) 6" x 5/16" lag screws, placing (3) roughly 6" on each side of the bearing truss spaced one at top, middle, and bottom of the LVL. It is my professional opinion this modification to the original plans designed by our firm will meet the codes and loads set by the Larimer County Building Department. Very truly yours, DOUGLAS INGERSOLL, EI, BSME MARK BENJAMIN, PE, MSCE, SECB, CPHC ❑Certified in the practice of structural engineering❑ ❑Certified Passive House Consultant[] Copies: (1) verified password secured document. If submitting to a building department, provide CJDE with an email contact so that we may send it directly per most building department's request. Engineered for the way you build ... ... Designed for the way you live. !i.0z.0a -07'00'