Loading...
HomeMy WebLinkAboutDMA PLAZA - Filed MA-MINOR AMENDMENT - 2021-02-04Community Development & Neighborhood Services 281 N. College Ave Fort Collins, CO 80524 970.221.6689 fcgov.com/DevelopmentReview Minor Amendment Decision Letter November 16, 2020 Russell Lee Ripley Design, Inc 419 Canyon Ave., Suite 200 Fort Collins, CO 80521 970-224-5828 russ.lee@ripleydesigninc.com Dear Russell, Thank you for application submittal Minor Amendment MA200043. This application has been received and reviewed in accordance with Section 2.2.10 - Amendments and Change of Use, of the City of Fort Collins Land Use Code. As of the date of this letter this application has been Approved. This final decision of the Director may be appealed to the Planning & Zoning Board, in accordance with Article II, Division 2.2.10(A)(5) of the Land Use Code, within 14 calendar days of the date of final action by the Director. This appeal shall be filed at the Development Review Center located at 281 N College Ave Fort Collins, CO 80524. Sincerely, Arlo Schumann Senior Zoning Inspector City of Fort Collins 970-221-6599 aschumann@fcgov.com GAS 16 13 7 8 8 10 4 BIKE RACKS (27) ENTRY AREA SEATING AREA PAVER ENTRY PLAZA ACCESSIBLE CONNECTION ON-STREET PARKING TO REMAIN FIRE TRUCK STAGING CAR CANOPY, RE: ARCH CAR CANOPY, RE: ARCH CAR CANOPY, RE: ARCH 6' METAL PICKET FENCE PATIO NEW CONCRETE DRIVE RE: GRADING PLAN ISLAND REMOVED AND ASPHALT PARKING SPACE ADDED ISLAND REMOVED AND ASPHALT PARKING SPACE ADDED BIKE RACKS (14) TRASH ROOM EXISTING PARALLEL PARKING ADDED HC SPACE ADDED HC SPACE PA PA PA PA PA BUILDING E E D D D GAS BTC - 1 PPI - 1 PFJ - 2 PPI - 1 CD - 2 CAK - 7 HA - 1 6 - CAK 7 - CAK 3 - RFO 1 - HA 1 - PPI 12 - BGB 1 - PPI 2 - PFJ 3 - CAK 2 - CD 1 - PPI BA - 1 14 - CAK 5 - DB 13 - CAK 4 - CAK 2 - DB CAK - 4 BTC - 2 HA - 2 PFJ - 3 CAK - 6 HSE - 8 CAK - 10 4 - RFO 6 - HSE 4 - RFO 4 - HSE 10 - HSE 8 - AAC HSE - 12 3 - AMO 1 - HA 2 - YFI 2 - PD CA2 - 2 HA - 3 2 - HA 3 - BH CAK - 8 9 - CAK BH - 5 BH - 5 4 - CAK CAK - 3 BH - 3 POTS WITH ANNUALS (3) 2 - MSI CAK - 6 1 - HA 4 - RFO BUILDING Schedule Symbol Label Quantity Manufacturer Catalog Number Description Lamp Number Lamps Filename Lumens Per Lamp Light Loss Factor Wattage 1 ISM CCT: 2920K DFR56-15-930_7850 LED_IS Module 1 FM-306-930 IES.ies 864 0.9 15.6 8 WAC LIGHTING DC-WE05-F30S-WT Surface-mounted Luminaires 1 DC-WE05-F30S- -WT.IES 2390 0.63 24.7841 8 Lithonia Lighting RADPT P3 30K ASY RADEAN Post-Top with P3 3000K Asymmetric distribution 1 RADPT_P3_30K _ASY.ies 6600 0.9 53.6184 6 Lithonia Lighting RADB LED P3 30K SYM DDBXD RADB LED P3 30K SYM DDBXD 1 RADB_LED_P3_ 30K_SYM_DDB XD.ies 947 0.9 13.44 33 WAC LIGHTING FM-W2510 Surface-mounted Luminaires 1 FM- W2510_IESF.IE S 2139 0.9 30.613 1 Lithonia Lighting WST LED P1 30K VW MVOLT WST LED, Performance package 1, 3000 K, visual comfort wide, MVOLT LED 1 WST_LED_P1_3 0K_VW_MVOLT. ies 1548 0.9 12 1 Lithonia Lighting WST LED P1 30K VF MVOLT WST LED, Performance package 1, 3000 K, visual comfort forward throw, MVOLT LED 1 WST_LED_P1_3 0K_VF_MVOLT.i es 1529 0.9 12 126 Kelvix PL3K-24V+CH- 006+WHITE(ROUND) ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION PROFESSIONAL ENGINEERING CONSULTANTS, P.A. 420 LINDEN STREET, SUITE 110 FORT COLLINS, CO 80524 970-232-9558 www.pec1.com 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. BUILDING IS EXISTING. CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. COPYRIGHT: Issued No. Description Date 1 2020-06-11 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON ARONSON MINOR AMENDMENT A R C H I T E C T U R E + D E S I G N MINOR AMENDMENT MINOR AMEND. RESUBMITTAL 2020-09-11 MINOR AMEND. RESUBMITTAL 2020-10-09 10/7/2020 4:45:07 PM 10/7/2020 4:45:07 PM BIM 360://180560-000 - DMA Plaza/180560-000-Master Electrical Model-R18.rvt E2 SITE LIGHTING CUTSHEETS DMA PLAZA MINOR AMENDMENT 300 REMINGTON STREET FORT COLLINS, CO 80524-2860 2018-68 PM1, PM2 1ST 100' - 0" 2ND 109' - 8" 3RD 118' - 4" 4TH 127' - 0" 5TH 135' - 8" 6TH 144' - 4" 7TH 153' - 0" 8TH 161' - 8" 9TH 170' - 4" 10TH 179' - 0" 11TH 187' - 8" ROOF 196' - 4" METAL PANEL SYSTEM COLOR 1 (WHITE) METAL PANEL SYSTEM COLOR 2 (LIGHT GRAY) METAL PANEL SYSTEM COLOR 3 (MED. GRAY) EXISTING ELEVATOR PENTHOUSE FLUSH-FACE PTAC GRILLES, TYP. EXISTING CONCRETE, REPAINTED. ARCHITECTURAL CAST STONE TILE RECESSED ACCENT METAL PANEL SYSTEM COLOR 3 (MED GRAY) EXISTING CONCRETE, REPAINTED. METAL PANEL SYSTEM COLOR 1 (WHITE) METAL PANEL SYSTEM COLOR 2 (LIGHT GRAY) METAL PANEL SYSTEM COLOR 3 (MED. GRAY) KNOX BOX TEXTURED SMOOTH EXPRESSED JOINT, TYP. 8" LETTERED ADDRESS EXHAUST VENT, TYP. PTAC LOUVER, TYP. DETACHED PAINTED STEEL-FRAME CANOPY. 1ST 100' - 0" 2ND 109' - 8" 3RD 118' - 4" 4TH 127' - 0" 5TH 135' - 8" 6TH 144' - 4" 7TH 153' - 0" 8TH 161' - 8" 9TH 170' - 4" 10TH 179' - 0" 11TH 187' - 8" ROOF 196' - 4" EXISTING ELEVATOR PENTHOUSE, REPAINTED FLUSH-FACE PTAC GRILLES, TYP. EXISTING CONCRETE, REPAINTED. ARCHITECTURAL CAST STONE TILE 9' - 8" 8' - 8" 8' - 8" 8' - 8" 8' - 8" 8' - 8" 8' - 8" 8' - 8" 8' - 8" 8' - 8" 8' - 8" EXISTING ROOF TOP ENCLOSURE EXISTING ROOF TOP ENCLOSURE METAL PANEL 18' - 5 3/4" 39' - 11 3/4" 18' - 1" 42' - 3 3/4" 18' - 5 3/4" METAL PANEL SYSTEM COLOR 2 (LIGHT GRAY) METAL PANEL SYSTEM COLOR 3 (MED. GRAY) METAL PANEL SYSTEM COLOR 2 (LIGHT GRAY) METAL PANEL SYSTEM COLOR 3 (MED. GRAY) VERTICAL REVEAL TO ALIGN WITH OUTSIDE EDGE OF WINDOW, TYP. FIRE DEPARTMENT CONNECTION PAINTED STEEL FRAME CANOPY ASSEMBLY OVER EAST BUILDING ENTRY AREA. DETACHED PAINTED STEEL FRAME PATIO CANOPY ASSEMBLY TO MATCH EAST BUILDING ENTRY AREA. PATIO AND FENCE PER CO P S S S EB XCEL REMINGTON STREET MATTHEWS STREET OLIVE STREET ALLEY UP UP R/F R/F R/F R/F DW DMA PLAZA BUILDING PARKING CANOPY #1 PARKING CANOPY #2 PKNG. CANOPY #3 PKNG. CANOPY #4 PKNG. CANOPY #5 PKNG. CANOPY #6 ELEV ELEV ELEV ELEV ELEV ELEV OLIVE ST. REMINGTON ST. ALLEY PARKING CANOPY #1 CL CL 18' - 0" TYP. TYP. 8' - 2" 154' - 0" PARKING CANOPY #2 CL CL 18' - 0" TYP. 8' - 2" 128' - 0" PARKING CANOPY #4 CL CL 18' - 0" TYP. 72' - 0" TYP. 8' - 2" PARKING CANOPY #3 CL CL 18' - 0" TYP. 64' - 0" TYP. 3 PROPOSED EAST ENTRY AND CANOPY PROPOSED AUTOMOBILE CANOPY (MODEL IMAGE) DRAWING NUMBER: 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE Plotted By: Brent Layout: 3 ARCHITECTURE Printed On: 6/11/2020 5:08 PM File Name: 3 ARCHITECTURE.dwg ORIGINAL SIZE 24X36 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION RIPLEY DESIGN INC. Russell Lee 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 Remington 1 LLLP 300 Remington Street Fort Collins, CO 8052 ARCHITECT APPLICANT VFLA ARCHITECTS Don Bernholtz 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER ARCHITECTURE MINOR AMENDMENT DMA PLAZA 01 MINOR AMENDMENT 2020.06.11 FORT COLLINS, CO R18-064 8' - 2" PARKING CANOPY #5 CL CL 18' - 0" TYP. 72' - 0" TYP. 8' - 2" PARKING CANOPY #6 CL CL 18' - 0" TYP. 90' - 0" TYP. 8' - 2" NOTE: PARKING CANOPY ELEVATIONS ARE PROVIDED BY REQUEST OF ZONING DEPARTMENT. VFLA REPRESENTS VISUAL DESIGN INTENT ONLY, AND THE CANOPY VENDOR WILL PROVIDE ENGINEERING AND FINAL SIZING OF ASSEMBLY STRUCTURES. PAINTED STEEL POST AND BEAM SUPPORTS - DARK GRAY. PAINTED STEEL PURLINS - DARK GRAY PREFINISHED METAL ROOF PANELS - BEIGE PAINTED STEEL POST AND BEAM SUPPORTS - DARK GRAY. PAINTED STEEL PURLINS - DARK GRAY PREFINISHED METAL ROOF PANELS - BEIGE PAINTED STEEL POST AND BEAM SUPPORTS - DARK GRAY. PAINTED STEEL PURLINS - DARK GRAY PREFINISHED METAL ROOF PANELS - BEIGE PAINTED STEEL POST AND BEAM SUPPORTS - DARK GRAY. PAINTED STEEL PURLINS - DARK GRAY PREFINISHED METAL ROOF PANELS - BEIGE PAINTED STEEL POST AND BEAM SUPPORTS - DARK GRAY. PAINTED STEEL PURLINS - DARK GRAY PREFINISHED METAL ROOF PANELS - BEIGE PAINTED STEEL POST AND BEAM SUPPORTS - DARK GRAY. PAINTED STEEL PURLINS - DARK GRAY PREFINISHED METAL ROOF PANELS - BEIGE TYP. TO B.O. PURLIN 8' - 2" 16' - 0" PAINTED STEEL POST AND BEAM SUPPORTS - DARK GRAY. PAINTED STEEL PURLINS - DARK GRAY PREFINISHED METAL ROOF PANELS - BEIGE CONCRETE PIER FOUNDATIONS NOTE: PARKING CANOPY SECTION IS PROVIDED BY REQUEST OF ZONING DEPARTMENT. VFLA REPRESENTS VISUAL DESIGN INTENT ONLY, AND THE CANOPY VENDOR WILL PROVIDE ENGINEERING AND FINAL SIZING OF ASSEMBLY STRUCTURES. 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: Issued No. Description Date 1 2020-06-11 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON ARONSON MINOR AMENDMENT A R C H I T E C T U R E + D E S I G N MINOR AMEND. RESUBMITTAL 2020-09-11 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION MINOR AMENDMENT DMA PLAZA MINOR AMENDMENT 9/10/2020 11:45:27 AM 9/10/2020 11:45:27 AM C:\Users\don.bernholtz\Documents\DMA Plaza v18_donNS9DV.rvt A3-5 PARKING CANOPIES 300 REMINGTON STREET FORT COLLINS, CO 80524-2860 2018-68 1 1" = 50'-0" KEY PLAN - PARKING CANOPIES 2 1/8" = 1'-0" PARKING CANOPY ELEVATIONS 3 1/4" = 1'-0" PARKING CANOPY TYP. SECTION LANDSCAPE AND CIVIL DRAWINGS. 13' - 2" 13' - 6" NOTE: CANOPIES DO NOT ENCROACH INTO THE EXISTING FIRE LANE. 11' - 6" 14' - 0" 1ST 100' - 0" 2ND 109' - 8" 3RD 118' - 4" 4TH 127' - 0" 5TH 135' - 8" 6TH 144' - 4" 7TH 153' - 0" 8TH 161' - 8" 9TH 170' - 4" 10TH 179' - 0" 11TH 187' - 8" ROOF 196' - 4" METAL PANEL SYSTEM COLOR 3 METAL PANEL SYSTEM COLOR 3 ARCHITECTURAL CAST STONE TILE 12' - 8 1/2" EXISTING SCREENED OPENINGS TO REMAIN 11' - 6" EXISTING PENTHOUSE LEGAL INFORMATION: LOTS 9 - 12, BLOCK 133, TOWN OF FORT COLLINS PARCEL NUMBER: 9712328909 OWNER: DMA PLAZA INC ZONING: DOWNTOWN DISTRICT (D), SUBDISTRICT: CANYON AVENUE 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: Issued No. Description Date 1 2020-06-11 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON ARONSON MINOR AMENDMENT A R C H I T E C T U R E + D E S I G N MINOR AMEND. RESUBMITTAL 2020-09-11 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION MINOR AMENDMENT DMA PLAZA MINOR AMENDMENT 9/10/2020 11:14:21 AM 9/10/2020 11:14:21 AM C:\Users\don.bernholtz\Documents\DMA Plaza v18_donNS9DV.rvt A3-4 BUILDING ELEVATIONS 300 REMINGTON STREET FORT COLLINS, CO 80524-2860 2018-68 1 1/8" = 1'-0" ELEVATION - EAST (NEW) 2 1/8" = 1'-0" ELEVATION - SOUTH (NEW) 9' - 0" 1ST 100' - 0" 2ND 109' - 8" 3RD 118' - 4" 4TH 127' - 0" 5TH 135' - 8" 6TH 144' - 4" 7TH 153' - 0" 8TH 161' - 8" 9TH 170' - 4" 10TH 179' - 0" 11TH 187' - 8" ROOF 196' - 4" EXISTING ELEVATOR PENTHOUSE EXISTING CONCRETE, REPAINTED. ARCHITECTURAL CAST STONE METAL PANEL SYSTEM COLOR 3 (MED. GRAY) METAL PANEL SYSTEM COLOR 3 (MED. GRAY) EXISTING SCREENED OPENINGS TO REMAIN EXISTING ROOF TOP ENCLOSURE 8" LETTERED ADDRESS PATIO AND FENCE PER LANDSCAPE AND CIVIL DRAWINGS. LEGAL INFORMATION: LOTS 9 - 12, BLOCK 133, TOWN OF FORT COLLINS PARCEL NUMBER: 9712328909 OWNER: DMA PLAZA INC ZONING: DOWNTOWN DISTRICT (D), SUBDISTRICT: CANYON AVENUE 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: Issued No. Description Date 1 2020-06-11 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON ARONSON MINOR AMENDMENT A R C H I T E C T U R E + D E S I G N MINOR AMEND. RESUBMITTAL 2020-09-11 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION MINOR AMENDMENT DMA PLAZA MINOR AMENDMENT 9/10/2020 11:21:44 AM 9/10/2020 11:21:44 AM C:\Users\don.bernholtz\Documents\DMA Plaza v18_donNS9DV.rvt A3-3 BUILDING ELEVATIONS 300 REMINGTON STREET FORT COLLINS, CO 80524-2860 2018-68 1 1/8" = 1'-0" ELEVATION - WEST (NEW) 2 1/8" = 1'-0" ELEVATION - NORTH (NEW) PL3K-24V+CH- 006+WHITE(ROUND) - 1ft 2835 Diode 10 PL3K-24V+CH- 006+WHITE(RO UND) - 1FT.ies 17 0.9 2.3 1 Lithonia Lighting RADPT P3 30K ASY HS RADEAN Post-Top with P3 3000K Asymmetric distribution with house-side shield 1 RADPT_P3_30K _ASY_HS.ies 5940 0.9 53.6184 Statistics Description Symbol Avg Max Min Max/Min Avg/Min 20' beyond prop line 0.2 fc 1.0 fc 0.0 fc N/A N/A site 3.2 fc 12.1 fc 0.1 fc 121.0:1 32.0:1 12.1 1.0 1.0 1.0 0.8 0.7 1.3 1.4 0.6 0.9 2.6 3.2 4.7 5.5 6.3 1.3 2.3 2.4 1.7 1.0 3.9 4.9 0.2 0.7 6.4 7.8 4.7 5.5 6.3 1.5 3.8 2.8 2.2 1.0 7.2 8.1 4.4 6.2 8.6 1.7 3.8 3.9 3.2 6.5 4.8 5.1 5.5 5.2 1.5 2.7 3.9 9.9 4.2 4.8 4.9 7.0 8.9 1.6 2.7 4.1 6.3 7.1 7.4 3.4 4.2 4.4 1.3 3.6 4.7 9.6 1.8 8.2 5.6 2.1 5.1 8.4 1.4 3.5 5.5 8.9 2.1 1.9 1.5 3.5 5.0 1.3 2.4 3.3 6.8 1.3 1.9 4.5 6.9 1.3 1.9 2.9 10.4 2.0 2.7 3.5 4.8 5.8 1.4 2.3 3.5 2.5 2.0 4.7 5.9 6.7 1.5 0.5 0.4 1.8 8.1 1.5 0.4 1.0 1.7 0.5 1.2 1.8 0.4 0.3 1.9 4.2 0.5 3.5 5.1 8.0 4.4 3.3 4.2 6.1 8.5 1.6 0.5 0.5 1.6 4.7 1.4 0.5 3.7 9.4 1.0 3.9 8.7 0.7 0.4 2.7 6.1 0.7 3.6 4.8 9.5 2.7 2.4 2.8 4.0 4.6 1.4 0.5 0.5 2.0 9.9 1.7 0.6 2.1 2.9 0.8 2.0 2.8 0.6 0.4 3.3 7.1 0.7 2.3 3.4 3.7 4.6 2.6 2.9 5.3 8.8 1.5 0.6 0.5 1.1 2.4 1.0 0.6 4.7 6.9 0.9 4.1 7.6 0.7 0.4 2.2 3.8 0.6 1.5 3.4 7.3 2.5 3.6 4.1 4.2 4.7 1.4 0.6 0.6 1.5 3.9 1.2 0.6 1.1 1.2 0.6 1.0 1.2 0.4 0.4 4.2 7.8 0.7 1.2 2.5 3.1 3.2 3.0 2.4 1.5 1.3 2.2 2.6 4.3 5.2 9.0 1.6 0.7 0.9 2.6 8.7 1.9 0.8 3.3 5.7 0.9 4.2 4.3 0.5 0.4 1.9 2.8 0.6 1.2 2.6 4.5 4.8 3.7 3.0 2.0 1.6 2.1 2.9 2.9 2.4 2.2 1.1 0.9 1.4 3.5 6.3 2.0 1.0 2.8 4.0 1.0 3.3 3.3 0.5 0.4 3.4 9.7 0.8 1.2 4.5 4.2 6.0 4.0 4.8 3.1 3.6 3.4 3.5 4.3 2.8 4.1 1.5 1.2 2.3 5.6 9.0 2.6 1.2 5.5 5.5 1.0 6.4 4.5 0.5 0.4 1.9 3.3 0.6 1.1 9.2 4.3 10.9 4.6 10.4 4.8 7.3 6.2 5.6 9.1 4.0 10.6 2.0 1.1 2.5 4.9 4.7 2.1 1.0 2.2 2.1 0.6 2.2 1.7 0.3 0.3 3.5 9.8 0.7 0.4 1.0 1.0 1.2 1.1 1.1 0.9 0.9 0.9 0.9 1.0 0.8 0.9 0.6 0.6 1.3 1.5 1.8 1.1 0.5 0.3 0.3 0.2 0.2 0.2 0.2 0.7 1.1 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.6 0.9 0.7 0.5 0.3 HA W2 PM1 B1 C5 GE1 GE2 LL1 PM2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 REMINGTON STREET MATTHEWS STREET ALLEY BUS SHELTER LOT 5 LOT 6 LOT 7 LOT 8 LOT 12 LOT 11 LOT 10 LOT 9 GAS PM1 PM1 PM1 PM1 PM1 PM1 PM1 CITY PROPERTY NOT IN SCOPE C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 PM1 B1 B1 B1 B1 B1 B1 LL1 LL1 LL1 LL1 HA LL1 LL1 LL1 LL1 W2 W2 W2 W2 W2 W2 W2 W2 GE1 GE2 NEW POLE MOUNTED FIXTURES 'PM1' REPLACE EXISTING OLD STYLE GLOBE FIXTURES IN SAME LOCATIONS. NEW FIXTURES ARE FULL CUT-OFF AND LED. TYPICAL EXISTING POLE MOUNTED FIXTURES REMOVED IN THIS PARKING AREA AND REPLACED WITH FULL CUT- LED FIXTURES UNDERNEATH CANOPIES. PM2 ALL EXTERIOR FIXTURES ARE SPECIFIED AT 3000K. FIXTURE PROVIDED WITH HOUSE SIDE SHIELD ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION PROFESSIONAL ENGINEERING CONSULTANTS, P.A. 420 LINDEN STREET, SUITE 110 FORT COLLINS, CO 80524 970-232-9558 www.pec1.com 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARCHITECTS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. BUILDING IS EXISTING. CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. COPYRIGHT: Issued No. Description Date 1 2020-06-11 Revisions 2 3 4 5 6 No. Description Date VAUGHT FRYE LARSON ARONSON MINOR AMENDMENT A R C H I T E C T U R E + D E S I G N MINOR AMENDMENT MINOR AMEND. RESUBMITTAL 2020-09-11 MINOR AMEND. RESUBMITTAL 2020-10-09 10/7/2020 4:45:06 PM 10/7/2020 4:45:06 PM BIM 360://180560-000 - DMA Plaza/180560-000-Master Electrical Model-R18.rvt E1 SITE PHOTOMETRIC PLAN DMA PLAZA MINOR AMENDMENT 300 REMINGTON STREET FORT COLLINS, CO 80524-2860 2018-68 1" = 20'-0" A SITE PHOTOMETRIC PLAN E E D D D D D AC AC AC T OLIVE STREET REMINGTON STREET LOTS 9-12, BLOCK 133 OWNER: REMINGTON 1, LLLP ALLEY FDC QTY BOTANICAL / COMMON NAME CONT CAL SIZE 5 PICEA PUNGENS `ISELI FASTIGIATE` / COLUMNARE COLORADO BLUE SPRUCE - - 6` HT QTY BOTANICAL / COMMON NAME SIZE 16 BERBERIS THUNBERGII `HELMOND PILLAR` / COLUMNAR BARBERRY 5 GAL 4 CARYOPTERIS X CLANDONENSIS `DARK KNIGHT` / BLUE MIST SHRUB 5 GAL 2 CORNUS SERICEA `ARTIC FIRE` / ARTIC FIRE DOGWOOD 5 GAL 7 DAPHNE X BURKWOODII `CAROL MACKIE` / CAROL MACKIE DAPHNE 5 GAL 11 HYDRANGEA ARBORESCENS `ANNABELLE` / ANNABELLE HYDRANGEA 5 GAL 2 PHYSOCARPUS OPULIFOLIUS `DIABLO` / DIABLO NINEBARK 5 GAL 1 BERBERIS THUNBERGII `ATROPURPUREA` / RED LEAF JAPANESE BARBERRY 5 GAL 7 POTENTILLA FRUTICOSA `JACKMANII` / JACKMAN POTENTILLA 5 GAL 3 BERBERIS THUNBERGII `CRIMSON PYGMY` / CRIMSON PYGMY JAPANESE BARBERRY 5 GAL 2 YUCCA FILAMENTOSA / YUCCA 5 GAL QTY BOTANICAL / COMMON NAME SIZE 12 BOUTELOUA GRACILIS `BLONDE AMBITION` / BLONDE AMBITION GRAMA GRASS 1 GAL 104 CALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER` / FEATHER REED GRASS 1 GAL 40 HELICTOTRICHON SEMPERVIRENS / BLUE AVENA/BLUE OAT GRASS 1 GAL 2 MISCANTHUS SINENSIS `GRACILLIMUS` / MAIDEN GRASS 5 GAL QTY BOTANICAL / COMMON NAME SIZE 3 ACHILLEA X `MOONSHINE` / MOONSHINE YARROW 1 GAL 8 AGASTACHE AURANTIACA `CORONADO` / CORONADO HYSSOP 1 GAL 15 RUDBECKIA FULGIDA `GOLDSTURM` / BLACK-EYED SUSAN 1 GAL E MAIN ENTRY D DOOR T TRANSFORMER AC A/C CONDENSER PAVERS GRAY CONCRETE R RAMP FDC FIRE DEPARTMENT CONNECTION WOOD MULCH IRRIGATED TURF ROCK MULCH COBBLE AND BOULDERS COBBLE AND BOULDERS TREES PPI SHRUBS BH CD CA2 DB HA PD BA PFJ BTC YFI ORNAMENTAL GRASS BGB CAK HSE MSI PERENNIAL AMO AAC RFO HYDROZONE AREA (SF) WATER NEEDED (GALLONS/SF) ANNUAL WATER USE (GALLONS) HIGH 592.00 18 10,656.00 MODERATE 2661.00 10 26,610.00 LOW 0.00 3 0.00 VERY LOW 0.00 0 0.00 TOTAL 3,253 11.4559 37,266 ANNUAL WATER USE NOT TO EXCEED 15 GAL./SF. AVERAGE OVER THE SITE 2 NORTH 0 05 10 20 SCALE: 1"=10'-0" 1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT. 2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. 3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8. THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN NEW TREES AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS 15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN TREES AND GAS LINES 9. PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN. 10. THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE 11. MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION. 12. ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES. 13. IRRIGATED TURF SHALL BE TEXAS BLUEGRASS/KENTUCKY BLUEGRASS HYBRID REVEILLE OR APPROVED EQUAL. 14. EDGING BETWEEN GRASS AND SHRUB BEDS SHALL BE 18" X 4" ROLLED TOP STEEL SET LEVEL WITH TOP OF SOD OR APPROVED EQUAL. LEGEND GENERAL LANDSCAPE NOTES PLANT SCHEDULE DRAWING NUMBER: 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE Plotted By: Russ Lee Layout: 2 LANDSCAPE PLAN Printed On: 10/9/2020 11:55 AM File Name: 2 LANDSCAPE PLAN.dwg ORIGINAL SIZE 24X36 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION RIPLEY DESIGN INC. Russell Lee 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 Remington 1 LLLP 300 Remington Street Fort Collins, CO 8052 ARCHITECT APPLICANT VFLA ARCHITECTS Don Bernholtz 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER LANDSCAPE PLAN MINOR AMENDMENT DMA PLAZA 03 MINOR AMEND. RE-SUBMITTAL 2020.10.09 02 MINOR AMEND. RE-SUBMITTAL 2020.09.11 01 MINOR AMENDMENT 2020.06.11 FORT COLLINS, CO R18-064 GROUND COVERS LANDSCAPE ISLANDS IN EAST PARKING LOT WATER BUDGET CHART D D AC AC AC T PA OLIVE STREET REMINGTON STREET LOTS 9-12, BLOCK 133 OWNER: REMINGTON 1, LLLP LOT 6, BLOCK 133 OWNER: REMINGTON 1, LLLP LOT 7, BLOCK 133 OWNER: CITY OF FORT COLLINS LOT 8, BLOCK 133 OWNER: CITY OF FORT COLLINS LOT 5, BLOCK 133 OWNER: REMINGTON 1, LLLP ALLEY MATTHEWS STREET R R R PA FDC 24'-0" EA ESMNT 26'-0" EA ESMNT 16'-4" 14'-7" ISLAND ADDED ISLAND ADDED 24'-0" 11'-9" 9'-2" GATE EMERGENCY ACCESS EASEMENT 4'-0" NEW WALK 6' METAL PICKET FENCE CANOPY, RE: ARCH DWGS CANOPY, RE: ARCH DWGS 'NO PARKING FIRE LANE' SIGN ADA PARKING SIGNS 'NO PARKING FIRE LANE' SIGN GATE NEW CURB AND GUTTER REPLACE CONCRETE AT DRIVE NEW CURB 'NO PARKING FIRE LANE' SIGN 'NO PARKING FIRE LANE' SIGN POLE LIGHT, TYP. PA PLANTING AREA E MAIN ENTRY D DOOR T TRANSFORMER AC A/C CONDENSER PAVERS R RAMP FDC FIRE DEPARTMENT CONNECTION NEW GRAY CONCRETE ASPHALT DRAWING NUMBER: 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE Plotted By: Russ Lee Layout: 1 SITE PLAN Printed On: 10/9/2020 11:55 AM File Name: 1 SITE PLAN.dwg ORIGINAL SIZE 24X36 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION RIPLEY DESIGN INC. Russell Lee 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 Remington 1 LLLP 300 Remington Street Fort Collins, CO 8052 ARCHITECT APPLICANT VFLA ARCHITECTS Don Bernholtz 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER SITE PLAN MINOR AMENDMENT DMA PLAZA 03 MINOR AMEND. RE-SUBMITTAL 2020.10.09 02 MINOR AMEND. RE-SUBMITTAL 2020.09.11 01 MINOR AMENDMENT 2020.06.11 FORT COLLINS, CO R18-064 1 NORTH 0 10 20 40 SCALE: 1"=20'-0" SITE PLAN NOTES 1. 1268 SF NEW IMPERVIOUS SURFACE ADDED. 419 SF IMPERVIOUS SURFACE REMOVED. 849 SF OF NEW IMPERVIOUS SURFACE LEGEND