Loading...
HomeMy WebLinkAboutGINGER AND BAKER - Filed MA-MINOR AMENDMENT - 2021-01-06MA200051 Oct. 14, 2020 Community Development & Neighborhood Services 281 N. College Ave Fort Collins, CO 80524 970.221.6689 fcgov.com/DevelopmentReview Minor Amendment Decision Letter October 14, 2020 Chris Aronson VFLA 419 Canyon Ave Suite 200 970-224-1191 chris@vfla.com Dear Mr. Aronson, Thank you for application submittal Minor Amendment MA200051. This application has been received and reviewed in accordance with Section 2.2.10 - Amendments and Change of Use, of the City of Fort Collins Land Use Code. As of the date of this letter this application has been Approved. This final decision of the Director may be appealed to the Planning & Zoning Board, in accordance with Article II, Division 2.2.10(A)(5) of the Land Use Code, within 14 calendar days of the date of final action by the Director. This appeal shall be filed at the Development Review Center located at 281 N College Ave Fort Collins, CO 80524. Sincerely, Arlo Schumann Senior Zoning Inspector City of Fort Collins 970-221-6599 aschumann@fcgov.com FIN. FLOOR 100' - 0" NEW BASEMENT EXISTING BASEMENT TO BE DUG OUT AN ADDITIONAL 2'-0" ADJACENT BUILDING SANDSTONE METAL PANEL STEEL CHANNEL, PAINTED METAL PANEL ALUMINUM STOREFRONT GLAZING, COLOR MUST BE CLEAR LOW-E IS ACCEPTABLE ALUMINUM STOREFRONT SPANDREL GLAZING EXISTING BUILDING STEEL RAILING AT NEW RAISED PATIO EXISTING STOREFRONT TO BE RESTORED EXISTING WINDOW TO BE RESTORED EXISTING LOUVER TO BE REPLACED WITH A HISTORICAL REPLICATION WINDOW PROPOSED SIGNAGE LOCATION (TO BE SUBMITTED AS A SEPARATE SIGNAGE PERMIT) REPLACE EXISTING WINDOW, REFER TO WINDOW SCHEDULE FOR DETAILS STAIRS AT SERVICE WINDOW EXISTING DOORS TO BE RESTORED PROPOSED STRUCTURE EXISTING STRUCTURE ALUMINUM STOREFRONT SPANDREL GLAZING STEEL COLUMN, PAINTED HISTORIC SCALE TO REMAIN NEW INTERPRETIVE SIGN AT HISTORIC SCALE PROPOSED SIGNAGE LOCATION (TO BE SUBMITTED AS A SEPARATE SIGNAGE PERMIT) PREFINISHED MECHANICAL SCREEN NOTE: NO SIGNAGE OR GRAPHICS TO BE ON GLAZING. INTERIOR MECHO WINDOW SHADES ARE ACCEPTABLE FIN. FLOOR 100' - 0" NEW BASEMENT LOCATION NEW STAIR TO BASEMENT ADJACENT OFFICE BUIDING INFILL OLD DOOR WITH RECLAIMED BRICK METAL PANELS STEEL CHANNEL, PAINTED STEEL RAILING AT NEW PATIO STEEL CHANNEL, PAINTED PRECAST CONCRETE BASE NON-COMBUSTIBLE CANOPY NEW DOOR OPENING REPLACE EXISTING LOUVER WITH HISTORICAL REPLICAITON WINDOW HOLLOW METAL DOOR METAL PANELS BRICK VENEER STEEL CHANNEL, PAINTED RIDGE OF MAIN ROOF 42' - 10" EXISTING STRUCTURE PROPOSED STRUCTURE ALUMINUM STOREFRONT GLAZING HOLLOW METAL DOOR SOLDIER COURSE BRICK DETAILING STEEL RAILING AT NEW PATIO TOP OF PARAPET AT PROPOSED STRUCTURE 37' - 9" EXISTING BRICK TO REMAIN EXISTING STONE TO REMAIN PREFINISHED MECHANICAL SCREEN ELECTRICAL PANELS GAS METER ELECT. TRANSFORMER VIP DINING 114' - 7" 17' - 1" 10' - 8" FIN. FLOOR 100' - 0" NEW BASEMENT ADJACENT APARTMENT BUILDING SANDSTONE METAL PANELS STEEL CHANNEL, PAINTED BRICK VENEER STEEL GATES FOR TRASH ENCLOSURE PROPOSED SIGNAGE LOCATION (TO BE SUBMITTED AS A SEPARATE SIGNAGE PERMIT) METAL PANEL STEEL COLUMN PROPOSED SIGNAGE LOCATION (TO BE SUBMITTED AS A SEPARATE SIGNAGE PERMIT) ALUMINUM STOREFRONT GLAZING SOLDIER COURSE BRICK DETAILING PRECAST STEEL CHANNEL CONCRETE BASE EXISTING BUILDING BEYOND TOP OF PARAPET AT PROPOSED STRUCTURE 38' - 0" PRE-CAST CONCRETE LINTELS STEEL RAILING STEEL CHANNEL, PAINTED ALUMINUM STOREFRONT GLAZING, COLOR MUST BE CLEAR LOW-E IS ACCEPTABLE NOTE: NO SIGNAGE OR GRAPHICS TO BE ON GLAZING. INTERIOR MECHO WINDOW SHADES ARE ACCEPTABLE EXTERIOR FINISH SCHEDULE ALUMINUM STOREFRONT FRAMES BRICK (EXISTING) BRICK (NEW) GLAZING (SPANDREL) GLAZING (VISION) METAL PANEL METAL ROOF PRECAST CONCRETE STEEL RAILINGS & CHANNELS STEEL TRASH ENCLOSURE GATES STONE STUCCO (EXISTING) WOOD DOORS (AT EXISTING STRUCTURE) WOOD WINDOWS (AT EXISTING STRUCTURE) PREFINISHED MECHANICAL SCREEN GENERAL NOTE: ALL EXTERIOR WALL MOUNTED LIGHTS TO BE FULL CUT-OFF. DARK GRAY REMAINS RED RED GRAY CLEAR MEDIUM GRAY SILVER (MATCH EXISTING HISTORIC) TAN DARK GRAY DARK GRAY LIGHT BUFF REPAINT WHITE TO MATCH EXISTING LIGHT GRAY LIGHT GRAY GREY 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. CHECKED BY: DRAWN BY: COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE REVISIONS No. Description Date VAUGHT FRYE LARSON ARONSON CA JH A R C H I T E C T U R E + I N T E R I O R S MINOR AMENDMENT SUBMITTAL 07-10-2020 MINOR AMENDMENT SUBMITTAL #2 08-10-2020 8/10/2020 2:16:38 PM 8/10/2020 2:16:38 PM G:\2019\19-23 Ginger & Baker Patio Canopy\5 Revit\Ginger+BakerV18.rvt 6 EXTERIOR ELEVATIONS GINGER & BAKER PATIO CANOPY 359 LINDEN STREET, FORT COLLINS, CO MINOR AMENDMENT #2 2019-23 1 1/8" = 1'-0" REAR ELEVATION - NORTHWEST 2 1/8" = 1'-0" ALLEY ELEVATION - SOUTHWEST MINOR AMENDMENT #MA200051 FC - 3 1 FC - 3 1 NON-COMBUSTIBLE CANOPY 17' - 1" 10' - 8" FIN. FLOOR 100' - 0" EXISTING BASEMENT TO BE DUG OUT 2'-0" ADJACENT APARTMENT BUIDLING (E) TRANSFORMER REPLACE EXISTING LOUVER WITH NEW WINDOW REPLACE ROOF WITH ROOFING TO MATCH EXISTING, METAL S- DECK REPAIR EXISTING WINDOW SANDSTONE REPLACE EXISTING LOUVER WITH WINDOW WOOD FIRED OVEN STEEL CANOPY METAL PANEL EXISTING BUILDING, NEW PAINT STEEL RAILING BRICK VENEER ALUMINUM STOREFRONT GLAZING STEEL CATWALK RIDGE OF MAIN ROOF 41' - 6" EXISTING STRUCTURE EXISTING STRUCTURE PROPOSED STRUCTURE NEW OCCUPIED DECK PROPOSED SIGNAGE LOCATION (TO BE SUBMITTED AS A SEPARATE SIGNAGE PERMIT) STEEL CHANNEL, PAINTED ALUMINUM STOREFRONT SPANDREL GLAZING SANDSTONE VIP DINING 114' - 7" NEW TRANSFORMER 10' - 8" 36' - 9" NON-COMBUSTIBLE CANOPY EXTERIOR FINISH SCHEDULE ALUMINUM STOREFRONT FRAMES BRICK (EXISTING) BRICK (NEW) GLAZING (SPANDREL) GLAZING (VISION) METAL PANEL METAL ROOF PRECAST CONCRETE STEEL RAILINGS & CHANNELS STEEL TRASH ENCLOSURE GATES STONE STUCCO (EXISTING) WOOD DOORS (AT EXISTING STRUCTURE) WOOD WINDOWS (AT EXISTING STRUCTURE) PREFINISHED MECHANICAL SCREEN GENERAL NOTE: ALL EXTERIOR WALL MOUNTED LIGHTS TO BE FULL CUT-OFF. DARK GRAY REMAINS RED RED GRAY CLEAR MEDIUM GRAY SILVER (MATCH EXISTING HISTORIC) TAN DARK GRAY DARK GRAY LIGHT BUFF REPAINT WHITE TO MATCH EXISTING LIGHT GRAY LIGHT GRAY GREY TREE PROTECTION NOTES TREE PROTECTION NOTES: 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T- POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE- HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G) (3)ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE- TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. CHECKED BY: DRAWN BY: COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE REVISIONS No. Description Date VAUGHT FRYE LARSON ARONSON CA JH A R C H I T E C T U R E + I N T E R I O R S MINOR AMENDMENT SUBMITTAL 07-10-2020 MINOR AMENDMENT SUBMITTAL #2 08-10-2020 8/10/2020 2:16:14 PM 8/10/2020 2:16:14 PM G:\2019\19-23 Ginger & Baker Patio Canopy\5 Revit\Ginger+BakerV18.rvt 5 EXTERIOR ELEVATIONS GINGER & BAKER PATIO CANOPY 359 LINDEN STREET, FORT COLLINS, CO MINOR AMENDMENT #2 2019-23 1 1/8" = 1'-0" FRONT ELEVATION - SOUTHEAST 2 1/8" = 1'-0" RIGHT ELEVATION - NORTHEAST MINOR AMENDMENT #MA200051 FC - 3 1 FC - 3 1